A Novel Fault-Tolerant Operation Approach for the Modular Multilevel Converter-Based STATCOM With the Enhanced Operation Capability Article Swipe
YOU?
·
· 2022
· Open Access
·
· DOI: https://doi.org/10.1109/jestpe.2022.3151911
The operation capability of the modular multilevel converter (MMC)-based static synchronous compensator (STATCOM) is limited under submodule (SM) failures. When running in the STATCOM mode, the floating dc-link voltage of the MMC is adjustable. Therefore, this article proposes a novel fault-tolerant operation approach to enhance the operation capability of the MMC under severe SM failures. First, the dc-link voltage is dynamically regulated under SM failures, where the capacitor voltages of all SMs are slightly increased. The modulation ranges of the faulty and healthy phases can be enlarged, and the even voltage stress distribution can be realized. Then, a low-magnitude fundamental frequency zero-sequence voltage (FF-ZSV) is injected to balance the line-to-line voltages. Finally, the virtual energy idea is proposed, where the capacitor voltages of faulty SMs are considered to be clamped at the reference value. As a result, the arm energy reference will be the same in all six arms, and the arm energy balancing control is simplified. Detailed comparisons show that the proposed approach has an enhanced operation capability with lower capacitor voltage increment. Simulation and experimental results verify that even under severe SM failures, the proposed approach can still guarantee the fault-tolerant operation within the specified security region.
Related Topics
- Type
- article
- Language
- en
- Landing Page
- https://doi.org/10.1109/jestpe.2022.3151911
- OA Status
- green
- Cited By
- 20
- References
- 29
- Related Works
- 10
- OpenAlex ID
- https://openalex.org/W4212911308
Raw OpenAlex JSON
- OpenAlex ID
-
https://openalex.org/W4212911308Canonical identifier for this work in OpenAlex
- DOI
-
https://doi.org/10.1109/jestpe.2022.3151911Digital Object Identifier
- Title
-
A Novel Fault-Tolerant Operation Approach for the Modular Multilevel Converter-Based STATCOM With the Enhanced Operation CapabilityWork title
- Type
-
articleOpenAlex work type
- Language
-
enPrimary language
- Publication year
-
2022Year of publication
- Publication date
-
2022-02-15Full publication date if available
- Authors
-
Yu Jin, Qian Xiao, Josep Pou, Hongjie Jia, Yanchao Ji, Remus Teodorescu, Frede BlaabjergList of authors in order
- Landing page
-
https://doi.org/10.1109/jestpe.2022.3151911Publisher landing page
- Open access
-
YesWhether a free full text is available
- OA status
-
greenOpen access status per OpenAlex
- OA URL
-
https://vbn.aau.dk/da/publications/d3993261-a1c6-443e-9aa8-b3a4993d4486Direct OA link when available
- Concepts
-
Voltage, Modular design, Capacitor, Fault (geology), Control theory (sociology), Computer science, Voltage reference, Fault tolerance, Energy (signal processing), Electronic engineering, Engineering, Electrical engineering, Control (management), Reliability engineering, Physics, Operating system, Quantum mechanics, Seismology, Geology, Artificial intelligenceTop concepts (fields/topics) attached by OpenAlex
- Cited by
-
20Total citation count in OpenAlex
- Citations by year (recent)
-
2025: 8, 2024: 7, 2023: 3, 2022: 2Per-year citation counts (last 5 years)
- References (count)
-
29Number of works referenced by this work
- Related works (count)
-
10Other works algorithmically related by OpenAlex
Full payload
| id | https://openalex.org/W4212911308 |
|---|---|
| doi | https://doi.org/10.1109/jestpe.2022.3151911 |
| ids.doi | https://doi.org/10.1109/jestpe.2022.3151911 |
| ids.openalex | https://openalex.org/W4212911308 |
| fwci | 2.15293441 |
| type | article |
| title | A Novel Fault-Tolerant Operation Approach for the Modular Multilevel Converter-Based STATCOM With the Enhanced Operation Capability |
| awards[0].id | https://openalex.org/G2062492940 |
| awards[0].funder_id | https://openalex.org/F4320321001 |
| awards[0].display_name | |
| awards[0].funder_award_id | 52061635103 |
| awards[0].funder_display_name | National Natural Science Foundation of China |
| awards[1].id | https://openalex.org/G5533375901 |
| awards[1].funder_id | https://openalex.org/F4320321001 |
| awards[1].display_name | |
| awards[1].funder_award_id | EP/T021969/1 |
| awards[1].funder_display_name | National Natural Science Foundation of China |
| biblio.issue | 5 |
| biblio.volume | 10 |
| biblio.last_page | 5552 |
| biblio.first_page | 5541 |
| topics[0].id | https://openalex.org/T11102 |
| topics[0].field.id | https://openalex.org/fields/22 |
| topics[0].field.display_name | Engineering |
| topics[0].score | 0.9998999834060669 |
| topics[0].domain.id | https://openalex.org/domains/3 |
| topics[0].domain.display_name | Physical Sciences |
| topics[0].subfield.id | https://openalex.org/subfields/2208 |
| topics[0].subfield.display_name | Electrical and Electronic Engineering |
| topics[0].display_name | HVDC Systems and Fault Protection |
| topics[1].id | https://openalex.org/T10223 |
| topics[1].field.id | https://openalex.org/fields/22 |
| topics[1].field.display_name | Engineering |
| topics[1].score | 0.9708999991416931 |
| topics[1].domain.id | https://openalex.org/domains/3 |
| topics[1].domain.display_name | Physical Sciences |
| topics[1].subfield.id | https://openalex.org/subfields/2207 |
| topics[1].subfield.display_name | Control and Systems Engineering |
| topics[1].display_name | Microgrid Control and Optimization |
| topics[2].id | https://openalex.org/T14502 |
| topics[2].field.id | https://openalex.org/fields/22 |
| topics[2].field.display_name | Engineering |
| topics[2].score | 0.9516000151634216 |
| topics[2].domain.id | https://openalex.org/domains/3 |
| topics[2].domain.display_name | Physical Sciences |
| topics[2].subfield.id | https://openalex.org/subfields/2208 |
| topics[2].subfield.display_name | Electrical and Electronic Engineering |
| topics[2].display_name | High-Voltage Power Transmission Systems |
| funders[0].id | https://openalex.org/F4320321001 |
| funders[0].ror | https://ror.org/01h0zpd94 |
| funders[0].display_name | National Natural Science Foundation of China |
| is_xpac | False |
| apc_list | |
| apc_paid | |
| concepts[0].id | https://openalex.org/C165801399 |
| concepts[0].level | 2 |
| concepts[0].score | 0.7081698179244995 |
| concepts[0].wikidata | https://www.wikidata.org/wiki/Q25428 |
| concepts[0].display_name | Voltage |
| concepts[1].id | https://openalex.org/C101468663 |
| concepts[1].level | 2 |
| concepts[1].score | 0.6971554756164551 |
| concepts[1].wikidata | https://www.wikidata.org/wiki/Q1620158 |
| concepts[1].display_name | Modular design |
| concepts[2].id | https://openalex.org/C52192207 |
| concepts[2].level | 3 |
| concepts[2].score | 0.6637059450149536 |
| concepts[2].wikidata | https://www.wikidata.org/wiki/Q5322 |
| concepts[2].display_name | Capacitor |
| concepts[3].id | https://openalex.org/C175551986 |
| concepts[3].level | 2 |
| concepts[3].score | 0.6220948696136475 |
| concepts[3].wikidata | https://www.wikidata.org/wiki/Q47089 |
| concepts[3].display_name | Fault (geology) |
| concepts[4].id | https://openalex.org/C47446073 |
| concepts[4].level | 3 |
| concepts[4].score | 0.5115474462509155 |
| concepts[4].wikidata | https://www.wikidata.org/wiki/Q5165890 |
| concepts[4].display_name | Control theory (sociology) |
| concepts[5].id | https://openalex.org/C41008148 |
| concepts[5].level | 0 |
| concepts[5].score | 0.46890556812286377 |
| concepts[5].wikidata | https://www.wikidata.org/wiki/Q21198 |
| concepts[5].display_name | Computer science |
| concepts[6].id | https://openalex.org/C44351266 |
| concepts[6].level | 3 |
| concepts[6].score | 0.4366600513458252 |
| concepts[6].wikidata | https://www.wikidata.org/wiki/Q1465532 |
| concepts[6].display_name | Voltage reference |
| concepts[7].id | https://openalex.org/C63540848 |
| concepts[7].level | 2 |
| concepts[7].score | 0.42223474383354187 |
| concepts[7].wikidata | https://www.wikidata.org/wiki/Q3140932 |
| concepts[7].display_name | Fault tolerance |
| concepts[8].id | https://openalex.org/C186370098 |
| concepts[8].level | 2 |
| concepts[8].score | 0.4137135446071625 |
| concepts[8].wikidata | https://www.wikidata.org/wiki/Q442787 |
| concepts[8].display_name | Energy (signal processing) |
| concepts[9].id | https://openalex.org/C24326235 |
| concepts[9].level | 1 |
| concepts[9].score | 0.37649911642074585 |
| concepts[9].wikidata | https://www.wikidata.org/wiki/Q126095 |
| concepts[9].display_name | Electronic engineering |
| concepts[10].id | https://openalex.org/C127413603 |
| concepts[10].level | 0 |
| concepts[10].score | 0.370513379573822 |
| concepts[10].wikidata | https://www.wikidata.org/wiki/Q11023 |
| concepts[10].display_name | Engineering |
| concepts[11].id | https://openalex.org/C119599485 |
| concepts[11].level | 1 |
| concepts[11].score | 0.26782912015914917 |
| concepts[11].wikidata | https://www.wikidata.org/wiki/Q43035 |
| concepts[11].display_name | Electrical engineering |
| concepts[12].id | https://openalex.org/C2775924081 |
| concepts[12].level | 2 |
| concepts[12].score | 0.2039463222026825 |
| concepts[12].wikidata | https://www.wikidata.org/wiki/Q55608371 |
| concepts[12].display_name | Control (management) |
| concepts[13].id | https://openalex.org/C200601418 |
| concepts[13].level | 1 |
| concepts[13].score | 0.14241883158683777 |
| concepts[13].wikidata | https://www.wikidata.org/wiki/Q2193887 |
| concepts[13].display_name | Reliability engineering |
| concepts[14].id | https://openalex.org/C121332964 |
| concepts[14].level | 0 |
| concepts[14].score | 0.08210179209709167 |
| concepts[14].wikidata | https://www.wikidata.org/wiki/Q413 |
| concepts[14].display_name | Physics |
| concepts[15].id | https://openalex.org/C111919701 |
| concepts[15].level | 1 |
| concepts[15].score | 0.0 |
| concepts[15].wikidata | https://www.wikidata.org/wiki/Q9135 |
| concepts[15].display_name | Operating system |
| concepts[16].id | https://openalex.org/C62520636 |
| concepts[16].level | 1 |
| concepts[16].score | 0.0 |
| concepts[16].wikidata | https://www.wikidata.org/wiki/Q944 |
| concepts[16].display_name | Quantum mechanics |
| concepts[17].id | https://openalex.org/C165205528 |
| concepts[17].level | 1 |
| concepts[17].score | 0.0 |
| concepts[17].wikidata | https://www.wikidata.org/wiki/Q83371 |
| concepts[17].display_name | Seismology |
| concepts[18].id | https://openalex.org/C127313418 |
| concepts[18].level | 0 |
| concepts[18].score | 0.0 |
| concepts[18].wikidata | https://www.wikidata.org/wiki/Q1069 |
| concepts[18].display_name | Geology |
| concepts[19].id | https://openalex.org/C154945302 |
| concepts[19].level | 1 |
| concepts[19].score | 0.0 |
| concepts[19].wikidata | https://www.wikidata.org/wiki/Q11660 |
| concepts[19].display_name | Artificial intelligence |
| keywords[0].id | https://openalex.org/keywords/voltage |
| keywords[0].score | 0.7081698179244995 |
| keywords[0].display_name | Voltage |
| keywords[1].id | https://openalex.org/keywords/modular-design |
| keywords[1].score | 0.6971554756164551 |
| keywords[1].display_name | Modular design |
| keywords[2].id | https://openalex.org/keywords/capacitor |
| keywords[2].score | 0.6637059450149536 |
| keywords[2].display_name | Capacitor |
| keywords[3].id | https://openalex.org/keywords/fault |
| keywords[3].score | 0.6220948696136475 |
| keywords[3].display_name | Fault (geology) |
| keywords[4].id | https://openalex.org/keywords/control-theory |
| keywords[4].score | 0.5115474462509155 |
| keywords[4].display_name | Control theory (sociology) |
| keywords[5].id | https://openalex.org/keywords/computer-science |
| keywords[5].score | 0.46890556812286377 |
| keywords[5].display_name | Computer science |
| keywords[6].id | https://openalex.org/keywords/voltage-reference |
| keywords[6].score | 0.4366600513458252 |
| keywords[6].display_name | Voltage reference |
| keywords[7].id | https://openalex.org/keywords/fault-tolerance |
| keywords[7].score | 0.42223474383354187 |
| keywords[7].display_name | Fault tolerance |
| keywords[8].id | https://openalex.org/keywords/energy |
| keywords[8].score | 0.4137135446071625 |
| keywords[8].display_name | Energy (signal processing) |
| keywords[9].id | https://openalex.org/keywords/electronic-engineering |
| keywords[9].score | 0.37649911642074585 |
| keywords[9].display_name | Electronic engineering |
| keywords[10].id | https://openalex.org/keywords/engineering |
| keywords[10].score | 0.370513379573822 |
| keywords[10].display_name | Engineering |
| keywords[11].id | https://openalex.org/keywords/electrical-engineering |
| keywords[11].score | 0.26782912015914917 |
| keywords[11].display_name | Electrical engineering |
| keywords[12].id | https://openalex.org/keywords/control |
| keywords[12].score | 0.2039463222026825 |
| keywords[12].display_name | Control (management) |
| keywords[13].id | https://openalex.org/keywords/reliability-engineering |
| keywords[13].score | 0.14241883158683777 |
| keywords[13].display_name | Reliability engineering |
| keywords[14].id | https://openalex.org/keywords/physics |
| keywords[14].score | 0.08210179209709167 |
| keywords[14].display_name | Physics |
| language | en |
| locations[0].id | doi:10.1109/jestpe.2022.3151911 |
| locations[0].is_oa | False |
| locations[0].source.id | https://openalex.org/S2764857692 |
| locations[0].source.issn | 2168-6777, 2168-6785 |
| locations[0].source.type | journal |
| locations[0].source.is_oa | False |
| locations[0].source.issn_l | 2168-6777 |
| locations[0].source.is_core | True |
| locations[0].source.is_in_doaj | False |
| locations[0].source.display_name | IEEE Journal of Emerging and Selected Topics in Power Electronics |
| locations[0].source.host_organization | https://openalex.org/P4310319808 |
| locations[0].source.host_organization_name | Institute of Electrical and Electronics Engineers |
| locations[0].source.host_organization_lineage | https://openalex.org/P4310319808 |
| locations[0].source.host_organization_lineage_names | Institute of Electrical and Electronics Engineers |
| locations[0].license | |
| locations[0].pdf_url | |
| locations[0].version | publishedVersion |
| locations[0].raw_type | journal-article |
| locations[0].license_id | |
| locations[0].is_accepted | True |
| locations[0].is_published | True |
| locations[0].raw_source_name | IEEE Journal of Emerging and Selected Topics in Power Electronics |
| locations[0].landing_page_url | https://doi.org/10.1109/jestpe.2022.3151911 |
| locations[1].id | pmh:oai:pure.atira.dk:openaire/d3993261-a1c6-443e-9aa8-b3a4993d4486 |
| locations[1].is_oa | True |
| locations[1].source.id | https://openalex.org/S4306400216 |
| locations[1].source.issn | |
| locations[1].source.type | repository |
| locations[1].source.is_oa | False |
| locations[1].source.issn_l | |
| locations[1].source.is_core | False |
| locations[1].source.is_in_doaj | False |
| locations[1].source.display_name | Research Portal (King's College London) |
| locations[1].source.host_organization | https://openalex.org/I183935753 |
| locations[1].source.host_organization_name | King's College London |
| locations[1].source.host_organization_lineage | https://openalex.org/I183935753 |
| locations[1].license | cc-by |
| locations[1].pdf_url | |
| locations[1].version | publishedVersion |
| locations[1].raw_type | info:eu-repo/semantics/publishedVersion |
| locations[1].license_id | https://openalex.org/licenses/cc-by |
| locations[1].is_accepted | True |
| locations[1].is_published | True |
| locations[1].raw_source_name | Jin, Y, Xiao, Q, Pou, J, Jia, H, Ji, Y, Teodorescu, R & Blaabjerg, F 2022, 'A Novel Fault-Tolerant Operation Approach for the Modular Multilevel Converter-Based STATCOM With the Enhanced Operation Capability', I E E E Journal of Emerging and Selected Topics in Power Electronics, vol. 10, no. 5, 9714363, pp. 5541 - 5552. https://doi.org/10.1109/JESTPE.2022.3151911 |
| locations[1].landing_page_url | https://vbn.aau.dk/da/publications/d3993261-a1c6-443e-9aa8-b3a4993d4486 |
| indexed_in | crossref |
| authorships[0].author.id | https://openalex.org/A5013366563 |
| authorships[0].author.orcid | https://orcid.org/0000-0003-3861-5089 |
| authorships[0].author.display_name | Yu Jin |
| authorships[0].countries | CN |
| authorships[0].affiliations[0].institution_ids | https://openalex.org/I204983213 |
| authorships[0].affiliations[0].raw_affiliation_string | Department of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China |
| authorships[0].institutions[0].id | https://openalex.org/I204983213 |
| authorships[0].institutions[0].ror | https://ror.org/01yqg2h08 |
| authorships[0].institutions[0].type | education |
| authorships[0].institutions[0].lineage | https://openalex.org/I204983213 |
| authorships[0].institutions[0].country_code | CN |
| authorships[0].institutions[0].display_name | Harbin Institute of Technology |
| authorships[0].author_position | first |
| authorships[0].raw_author_name | Yu Jin |
| authorships[0].is_corresponding | False |
| authorships[0].raw_affiliation_strings | Department of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China |
| authorships[1].author.id | https://openalex.org/A5082921193 |
| authorships[1].author.orcid | https://orcid.org/0000-0002-4986-4438 |
| authorships[1].author.display_name | Qian Xiao |
| authorships[1].countries | CN |
| authorships[1].affiliations[0].institution_ids | https://openalex.org/I162868743 |
| authorships[1].affiliations[0].raw_affiliation_string | Key Laboratory of Smart Grid of Ministry of Education and the Key Laboratory of Smart Energy and Information Technology of Tianjin Municipality, Tianjin University, Tianjin, China |
| authorships[1].institutions[0].id | https://openalex.org/I162868743 |
| authorships[1].institutions[0].ror | https://ror.org/012tb2g32 |
| authorships[1].institutions[0].type | education |
| authorships[1].institutions[0].lineage | https://openalex.org/I162868743 |
| authorships[1].institutions[0].country_code | CN |
| authorships[1].institutions[0].display_name | Tianjin University |
| authorships[1].author_position | middle |
| authorships[1].raw_author_name | Qian Xiao |
| authorships[1].is_corresponding | False |
| authorships[1].raw_affiliation_strings | Key Laboratory of Smart Grid of Ministry of Education and the Key Laboratory of Smart Energy and Information Technology of Tianjin Municipality, Tianjin University, Tianjin, China |
| authorships[2].author.id | https://openalex.org/A5002357319 |
| authorships[2].author.orcid | https://orcid.org/0000-0002-3114-781X |
| authorships[2].author.display_name | Josep Pou |
| authorships[2].countries | SG |
| authorships[2].affiliations[0].institution_ids | https://openalex.org/I172675005 |
| authorships[2].affiliations[0].raw_affiliation_string | School of Electrical and Electronic Engineering, Nanyang Technology University, Singapore |
| authorships[2].institutions[0].id | https://openalex.org/I172675005 |
| authorships[2].institutions[0].ror | https://ror.org/02e7b5302 |
| authorships[2].institutions[0].type | education |
| authorships[2].institutions[0].lineage | https://openalex.org/I172675005 |
| authorships[2].institutions[0].country_code | SG |
| authorships[2].institutions[0].display_name | Nanyang Technological University |
| authorships[2].author_position | middle |
| authorships[2].raw_author_name | Josep Pou |
| authorships[2].is_corresponding | False |
| authorships[2].raw_affiliation_strings | School of Electrical and Electronic Engineering, Nanyang Technology University, Singapore |
| authorships[3].author.id | https://openalex.org/A5053616362 |
| authorships[3].author.orcid | https://orcid.org/0000-0003-2907-2895 |
| authorships[3].author.display_name | Hongjie Jia |
| authorships[3].countries | CN |
| authorships[3].affiliations[0].institution_ids | https://openalex.org/I162868743 |
| authorships[3].affiliations[0].raw_affiliation_string | Key Laboratory of Smart Grid of Ministry of Education and the Key Laboratory of Smart Energy and Information Technology of Tianjin Municipality, Tianjin University, Tianjin, China |
| authorships[3].institutions[0].id | https://openalex.org/I162868743 |
| authorships[3].institutions[0].ror | https://ror.org/012tb2g32 |
| authorships[3].institutions[0].type | education |
| authorships[3].institutions[0].lineage | https://openalex.org/I162868743 |
| authorships[3].institutions[0].country_code | CN |
| authorships[3].institutions[0].display_name | Tianjin University |
| authorships[3].author_position | middle |
| authorships[3].raw_author_name | Hongjie Jia |
| authorships[3].is_corresponding | False |
| authorships[3].raw_affiliation_strings | Key Laboratory of Smart Grid of Ministry of Education and the Key Laboratory of Smart Energy and Information Technology of Tianjin Municipality, Tianjin University, Tianjin, China |
| authorships[4].author.id | https://openalex.org/A5103269914 |
| authorships[4].author.orcid | https://orcid.org/0000-0002-4668-6613 |
| authorships[4].author.display_name | Yanchao Ji |
| authorships[4].countries | CN |
| authorships[4].affiliations[0].institution_ids | https://openalex.org/I204983213 |
| authorships[4].affiliations[0].raw_affiliation_string | Department of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China |
| authorships[4].institutions[0].id | https://openalex.org/I204983213 |
| authorships[4].institutions[0].ror | https://ror.org/01yqg2h08 |
| authorships[4].institutions[0].type | education |
| authorships[4].institutions[0].lineage | https://openalex.org/I204983213 |
| authorships[4].institutions[0].country_code | CN |
| authorships[4].institutions[0].display_name | Harbin Institute of Technology |
| authorships[4].author_position | middle |
| authorships[4].raw_author_name | Yanchao Ji |
| authorships[4].is_corresponding | False |
| authorships[4].raw_affiliation_strings | Department of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China |
| authorships[5].author.id | https://openalex.org/A5019644280 |
| authorships[5].author.orcid | https://orcid.org/0000-0002-2617-7168 |
| authorships[5].author.display_name | Remus Teodorescu |
| authorships[5].countries | DK |
| authorships[5].affiliations[0].institution_ids | https://openalex.org/I891191580 |
| authorships[5].affiliations[0].raw_affiliation_string | Department of Energy Technology, Aalborg University, Aalborg, Denmark |
| authorships[5].institutions[0].id | https://openalex.org/I891191580 |
| authorships[5].institutions[0].ror | https://ror.org/04m5j1k67 |
| authorships[5].institutions[0].type | education |
| authorships[5].institutions[0].lineage | https://openalex.org/I891191580 |
| authorships[5].institutions[0].country_code | DK |
| authorships[5].institutions[0].display_name | Aalborg University |
| authorships[5].author_position | middle |
| authorships[5].raw_author_name | Remus Teodorescu |
| authorships[5].is_corresponding | False |
| authorships[5].raw_affiliation_strings | Department of Energy Technology, Aalborg University, Aalborg, Denmark |
| authorships[6].author.id | https://openalex.org/A5039395705 |
| authorships[6].author.orcid | https://orcid.org/0000-0001-8311-7412 |
| authorships[6].author.display_name | Frede Blaabjerg |
| authorships[6].countries | DK |
| authorships[6].affiliations[0].institution_ids | https://openalex.org/I891191580 |
| authorships[6].affiliations[0].raw_affiliation_string | Department of Energy Technology, Aalborg University, Aalborg, Denmark |
| authorships[6].institutions[0].id | https://openalex.org/I891191580 |
| authorships[6].institutions[0].ror | https://ror.org/04m5j1k67 |
| authorships[6].institutions[0].type | education |
| authorships[6].institutions[0].lineage | https://openalex.org/I891191580 |
| authorships[6].institutions[0].country_code | DK |
| authorships[6].institutions[0].display_name | Aalborg University |
| authorships[6].author_position | last |
| authorships[6].raw_author_name | Frede Blaabjerg |
| authorships[6].is_corresponding | False |
| authorships[6].raw_affiliation_strings | Department of Energy Technology, Aalborg University, Aalborg, Denmark |
| has_content.pdf | False |
| has_content.grobid_xml | False |
| is_paratext | False |
| open_access.is_oa | True |
| open_access.oa_url | https://vbn.aau.dk/da/publications/d3993261-a1c6-443e-9aa8-b3a4993d4486 |
| open_access.oa_status | green |
| open_access.any_repository_has_fulltext | False |
| created_date | 2025-10-10T00:00:00 |
| display_name | A Novel Fault-Tolerant Operation Approach for the Modular Multilevel Converter-Based STATCOM With the Enhanced Operation Capability |
| has_fulltext | False |
| is_retracted | False |
| updated_date | 2025-11-06T03:46:38.306776 |
| primary_topic.id | https://openalex.org/T11102 |
| primary_topic.field.id | https://openalex.org/fields/22 |
| primary_topic.field.display_name | Engineering |
| primary_topic.score | 0.9998999834060669 |
| primary_topic.domain.id | https://openalex.org/domains/3 |
| primary_topic.domain.display_name | Physical Sciences |
| primary_topic.subfield.id | https://openalex.org/subfields/2208 |
| primary_topic.subfield.display_name | Electrical and Electronic Engineering |
| primary_topic.display_name | HVDC Systems and Fault Protection |
| related_works | https://openalex.org/W4398198689, https://openalex.org/W2354365353, https://openalex.org/W1988437325, https://openalex.org/W2811287415, https://openalex.org/W2354835317, https://openalex.org/W2130152888, https://openalex.org/W2003918017, https://openalex.org/W2171140818, https://openalex.org/W2906102508, https://openalex.org/W2378076731 |
| cited_by_count | 20 |
| counts_by_year[0].year | 2025 |
| counts_by_year[0].cited_by_count | 8 |
| counts_by_year[1].year | 2024 |
| counts_by_year[1].cited_by_count | 7 |
| counts_by_year[2].year | 2023 |
| counts_by_year[2].cited_by_count | 3 |
| counts_by_year[3].year | 2022 |
| counts_by_year[3].cited_by_count | 2 |
| locations_count | 2 |
| best_oa_location.id | pmh:oai:pure.atira.dk:openaire/d3993261-a1c6-443e-9aa8-b3a4993d4486 |
| best_oa_location.is_oa | True |
| best_oa_location.source.id | https://openalex.org/S4306400216 |
| best_oa_location.source.issn | |
| best_oa_location.source.type | repository |
| best_oa_location.source.is_oa | False |
| best_oa_location.source.issn_l | |
| best_oa_location.source.is_core | False |
| best_oa_location.source.is_in_doaj | False |
| best_oa_location.source.display_name | Research Portal (King's College London) |
| best_oa_location.source.host_organization | https://openalex.org/I183935753 |
| best_oa_location.source.host_organization_name | King's College London |
| best_oa_location.source.host_organization_lineage | https://openalex.org/I183935753 |
| best_oa_location.license | cc-by |
| best_oa_location.pdf_url | |
| best_oa_location.version | publishedVersion |
| best_oa_location.raw_type | info:eu-repo/semantics/publishedVersion |
| best_oa_location.license_id | https://openalex.org/licenses/cc-by |
| best_oa_location.is_accepted | True |
| best_oa_location.is_published | True |
| best_oa_location.raw_source_name | Jin, Y, Xiao, Q, Pou, J, Jia, H, Ji, Y, Teodorescu, R & Blaabjerg, F 2022, 'A Novel Fault-Tolerant Operation Approach for the Modular Multilevel Converter-Based STATCOM With the Enhanced Operation Capability', I E E E Journal of Emerging and Selected Topics in Power Electronics, vol. 10, no. 5, 9714363, pp. 5541 - 5552. https://doi.org/10.1109/JESTPE.2022.3151911 |
| best_oa_location.landing_page_url | https://vbn.aau.dk/da/publications/d3993261-a1c6-443e-9aa8-b3a4993d4486 |
| primary_location.id | doi:10.1109/jestpe.2022.3151911 |
| primary_location.is_oa | False |
| primary_location.source.id | https://openalex.org/S2764857692 |
| primary_location.source.issn | 2168-6777, 2168-6785 |
| primary_location.source.type | journal |
| primary_location.source.is_oa | False |
| primary_location.source.issn_l | 2168-6777 |
| primary_location.source.is_core | True |
| primary_location.source.is_in_doaj | False |
| primary_location.source.display_name | IEEE Journal of Emerging and Selected Topics in Power Electronics |
| primary_location.source.host_organization | https://openalex.org/P4310319808 |
| primary_location.source.host_organization_name | Institute of Electrical and Electronics Engineers |
| primary_location.source.host_organization_lineage | https://openalex.org/P4310319808 |
| primary_location.source.host_organization_lineage_names | Institute of Electrical and Electronics Engineers |
| primary_location.license | |
| primary_location.pdf_url | |
| primary_location.version | publishedVersion |
| primary_location.raw_type | journal-article |
| primary_location.license_id | |
| primary_location.is_accepted | True |
| primary_location.is_published | True |
| primary_location.raw_source_name | IEEE Journal of Emerging and Selected Topics in Power Electronics |
| primary_location.landing_page_url | https://doi.org/10.1109/jestpe.2022.3151911 |
| publication_date | 2022-02-15 |
| publication_year | 2022 |
| referenced_works | https://openalex.org/W3138086999, https://openalex.org/W2905404992, https://openalex.org/W3108623651, https://openalex.org/W2940626296, https://openalex.org/W2995207941, https://openalex.org/W2744943726, https://openalex.org/W3093533734, https://openalex.org/W2991501580, https://openalex.org/W2520088960, https://openalex.org/W2592429078, https://openalex.org/W2524399879, https://openalex.org/W2769642977, https://openalex.org/W2795390662, https://openalex.org/W3011090170, https://openalex.org/W2177731164, https://openalex.org/W2557776372, https://openalex.org/W2887043601, https://openalex.org/W2955725153, https://openalex.org/W2969336592, https://openalex.org/W3004516918, https://openalex.org/W2174980551, https://openalex.org/W2331730087, https://openalex.org/W2553648428, https://openalex.org/W2793426681, https://openalex.org/W2907472411, https://openalex.org/W2999478524, https://openalex.org/W2796161777, https://openalex.org/W3082003379, https://openalex.org/W3120783285 |
| referenced_works_count | 29 |
| abstract_inverted_index.a | 38, 97, 135 |
| abstract_inverted_index.As | 134 |
| abstract_inverted_index.SM | 53, 63, 183 |
| abstract_inverted_index.an | 165 |
| abstract_inverted_index.at | 130 |
| abstract_inverted_index.be | 85, 94, 128, 142 |
| abstract_inverted_index.in | 21, 145 |
| abstract_inverted_index.is | 13, 32, 59, 104, 116, 155 |
| abstract_inverted_index.of | 3, 29, 48, 69, 78, 122 |
| abstract_inverted_index.to | 43, 106, 127 |
| abstract_inverted_index.MMC | 31, 50 |
| abstract_inverted_index.SMs | 71, 124 |
| abstract_inverted_index.The | 0, 75 |
| abstract_inverted_index.all | 70, 146 |
| abstract_inverted_index.and | 81, 87, 149, 175 |
| abstract_inverted_index.are | 72, 125 |
| abstract_inverted_index.arm | 138, 151 |
| abstract_inverted_index.can | 84, 93, 188 |
| abstract_inverted_index.has | 164 |
| abstract_inverted_index.six | 147 |
| abstract_inverted_index.the | 4, 22, 25, 30, 45, 49, 56, 66, 79, 88, 108, 112, 119, 131, 137, 143, 150, 161, 185, 191, 195 |
| abstract_inverted_index.(SM) | 17 |
| abstract_inverted_index.When | 19 |
| abstract_inverted_index.even | 89, 180 |
| abstract_inverted_index.idea | 115 |
| abstract_inverted_index.same | 144 |
| abstract_inverted_index.show | 159 |
| abstract_inverted_index.that | 160, 179 |
| abstract_inverted_index.this | 35 |
| abstract_inverted_index.will | 141 |
| abstract_inverted_index.with | 169 |
| abstract_inverted_index.Then, | 96 |
| abstract_inverted_index.arms, | 148 |
| abstract_inverted_index.lower | 170 |
| abstract_inverted_index.mode, | 24 |
| abstract_inverted_index.novel | 39 |
| abstract_inverted_index.still | 189 |
| abstract_inverted_index.under | 15, 51, 62, 181 |
| abstract_inverted_index.where | 65, 118 |
| abstract_inverted_index.First, | 55 |
| abstract_inverted_index.energy | 114, 139, 152 |
| abstract_inverted_index.faulty | 80, 123 |
| abstract_inverted_index.phases | 83 |
| abstract_inverted_index.ranges | 77 |
| abstract_inverted_index.severe | 52, 182 |
| abstract_inverted_index.static | 9 |
| abstract_inverted_index.stress | 91 |
| abstract_inverted_index.value. | 133 |
| abstract_inverted_index.verify | 178 |
| abstract_inverted_index.within | 194 |
| abstract_inverted_index.STATCOM | 23 |
| abstract_inverted_index.article | 36 |
| abstract_inverted_index.balance | 107 |
| abstract_inverted_index.clamped | 129 |
| abstract_inverted_index.control | 154 |
| abstract_inverted_index.dc-link | 27, 57 |
| abstract_inverted_index.enhance | 44 |
| abstract_inverted_index.healthy | 82 |
| abstract_inverted_index.limited | 14 |
| abstract_inverted_index.modular | 5 |
| abstract_inverted_index.region. | 198 |
| abstract_inverted_index.result, | 136 |
| abstract_inverted_index.results | 177 |
| abstract_inverted_index.running | 20 |
| abstract_inverted_index.virtual | 113 |
| abstract_inverted_index.voltage | 28, 58, 90, 102, 172 |
| abstract_inverted_index.(FF-ZSV) | 103 |
| abstract_inverted_index.Detailed | 157 |
| abstract_inverted_index.Finally, | 111 |
| abstract_inverted_index.approach | 42, 163, 187 |
| abstract_inverted_index.enhanced | 166 |
| abstract_inverted_index.floating | 26 |
| abstract_inverted_index.injected | 105 |
| abstract_inverted_index.proposed | 162, 186 |
| abstract_inverted_index.proposes | 37 |
| abstract_inverted_index.security | 197 |
| abstract_inverted_index.slightly | 73 |
| abstract_inverted_index.voltages | 68, 121 |
| abstract_inverted_index.(STATCOM) | 12 |
| abstract_inverted_index.balancing | 153 |
| abstract_inverted_index.capacitor | 67, 120, 171 |
| abstract_inverted_index.converter | 7 |
| abstract_inverted_index.enlarged, | 86 |
| abstract_inverted_index.failures, | 64, 184 |
| abstract_inverted_index.failures. | 18, 54 |
| abstract_inverted_index.frequency | 100 |
| abstract_inverted_index.guarantee | 190 |
| abstract_inverted_index.operation | 1, 41, 46, 167, 193 |
| abstract_inverted_index.proposed, | 117 |
| abstract_inverted_index.realized. | 95 |
| abstract_inverted_index.reference | 132, 140 |
| abstract_inverted_index.regulated | 61 |
| abstract_inverted_index.specified | 196 |
| abstract_inverted_index.submodule | 16 |
| abstract_inverted_index.voltages. | 110 |
| abstract_inverted_index.Simulation | 174 |
| abstract_inverted_index.Therefore, | 34 |
| abstract_inverted_index.capability | 2, 47, 168 |
| abstract_inverted_index.considered | 126 |
| abstract_inverted_index.increased. | 74 |
| abstract_inverted_index.increment. | 173 |
| abstract_inverted_index.modulation | 76 |
| abstract_inverted_index.multilevel | 6 |
| abstract_inverted_index.(MMC)-based | 8 |
| abstract_inverted_index.adjustable. | 33 |
| abstract_inverted_index.comparisons | 158 |
| abstract_inverted_index.compensator | 11 |
| abstract_inverted_index.dynamically | 60 |
| abstract_inverted_index.fundamental | 99 |
| abstract_inverted_index.simplified. | 156 |
| abstract_inverted_index.synchronous | 10 |
| abstract_inverted_index.distribution | 92 |
| abstract_inverted_index.experimental | 176 |
| abstract_inverted_index.line-to-line | 109 |
| abstract_inverted_index.low-magnitude | 98 |
| abstract_inverted_index.zero-sequence | 101 |
| abstract_inverted_index.fault-tolerant | 40, 192 |
| cited_by_percentile_year.max | 99 |
| cited_by_percentile_year.min | 94 |
| countries_distinct_count | 3 |
| institutions_distinct_count | 7 |
| sustainable_development_goals[0].id | https://metadata.un.org/sdg/7 |
| sustainable_development_goals[0].score | 0.8999999761581421 |
| sustainable_development_goals[0].display_name | Affordable and clean energy |
| citation_normalized_percentile.value | 0.86012948 |
| citation_normalized_percentile.is_in_top_1_percent | False |
| citation_normalized_percentile.is_in_top_10_percent | False |