Computational analysis of hip prosthesis: Impact of shape and material on mechanical performance Article Swipe
YOU?
·
· 2025
· Open Access
·
· DOI: https://doi.org/10.5937/jaes0-55883
Hip implants play a crucial role in restoring mobility and reducing pain in patients with hip joint disorders. The design and material selection of the implant stem significantly influence its mechanical performance and longevity. This study presents a comparative finite element analysis of circular and rectangular hip implant stems to evaluate their structural behaviour under static loading conditions. The implant stems were modeled using CREO 11.0 and analysed using Ansys 2023 R2, with a load of 2300 N applied to simulate real-world conditions. Two materials-Cobalt Chromium (CoCr) and Ti-6Al-4V alloys-were considered to assess their mechanical properties. The results indicate that rectangular stems exhibited lower total deformation, von Mises stress, and strain compared to circular stems, making them structurally superior. Among the materials analysed, CoCr demonstrated better mechanical performance, reducing stress concentration and potential failure risks. Additionally, metal-on-metal (MoM) configurations showed enhanced durability over metal-on-polyethylene (MoPE). These findings suggest that a rectangular CoCr stem in a MoM configuration is optimal for improving implant longevity and reducing revision surgery rates. The study underscores the importance of optimized implant geometry and material selection in total hip arthroplasty. Future research should explore dynamic loading conditions and patient-specific implant designs to enhance clinical outcomes further.
Related Topics
- Type
- article
- Language
- en
- Landing Page
- https://doi.org/10.5937/jaes0-55883
- https://aseestant.ceon.rs/index.php/jaes/article/download/55883/27508
- OA Status
- gold
- Cited By
- 1
- References
- 23
- Related Works
- 10
- OpenAlex ID
- https://openalex.org/W4409273281
Raw OpenAlex JSON
- OpenAlex ID
-
https://openalex.org/W4409273281Canonical identifier for this work in OpenAlex
- DOI
-
https://doi.org/10.5937/jaes0-55883Digital Object Identifier
- Title
-
Computational analysis of hip prosthesis: Impact of shape and material on mechanical performanceWork title
- Type
-
articleOpenAlex work type
- Language
-
enPrimary language
- Publication year
-
2025Year of publication
- Publication date
-
2025-01-01Full publication date if available
- Authors
-
Nishant Nikam, B. Satish Shenoy, Laxmikant G. Keni, Sawan Shetty, Shyamasunder N Bhat, K N ChethanList of authors in order
- Landing page
-
https://doi.org/10.5937/jaes0-55883Publisher landing page
- PDF URL
-
https://aseestant.ceon.rs/index.php/jaes/article/download/55883/27508Direct link to full text PDF
- Open access
-
YesWhether a free full text is available
- OA status
-
goldOpen access status per OpenAlex
- OA URL
-
https://aseestant.ceon.rs/index.php/jaes/article/download/55883/27508Direct OA link when available
- Concepts
-
Prosthesis, Materials science, Composite material, Mechanical engineering, Structural engineering, Computer science, Engineering, Artificial intelligenceTop concepts (fields/topics) attached by OpenAlex
- Cited by
-
1Total citation count in OpenAlex
- Citations by year (recent)
-
2025: 1Per-year citation counts (last 5 years)
- References (count)
-
23Number of works referenced by this work
- Related works (count)
-
10Other works algorithmically related by OpenAlex
Full payload
| id | https://openalex.org/W4409273281 |
|---|---|
| doi | https://doi.org/10.5937/jaes0-55883 |
| ids.doi | https://doi.org/10.5937/jaes0-55883 |
| ids.openalex | https://openalex.org/W4409273281 |
| fwci | 6.62138127 |
| type | article |
| title | Computational analysis of hip prosthesis: Impact of shape and material on mechanical performance |
| biblio.issue | 2 |
| biblio.volume | 23 |
| biblio.last_page | 321 |
| biblio.first_page | 314 |
| topics[0].id | https://openalex.org/T10512 |
| topics[0].field.id | https://openalex.org/fields/27 |
| topics[0].field.display_name | Medicine |
| topics[0].score | 0.9990000128746033 |
| topics[0].domain.id | https://openalex.org/domains/4 |
| topics[0].domain.display_name | Health Sciences |
| topics[0].subfield.id | https://openalex.org/subfields/2746 |
| topics[0].subfield.display_name | Surgery |
| topics[0].display_name | Orthopaedic implants and arthroplasty |
| topics[1].id | https://openalex.org/T12932 |
| topics[1].field.id | https://openalex.org/fields/22 |
| topics[1].field.display_name | Engineering |
| topics[1].score | 0.9230999946594238 |
| topics[1].domain.id | https://openalex.org/domains/3 |
| topics[1].domain.display_name | Physical Sciences |
| topics[1].subfield.id | https://openalex.org/subfields/2210 |
| topics[1].subfield.display_name | Mechanical Engineering |
| topics[1].display_name | Powder Metallurgy Techniques and Materials |
| is_xpac | False |
| apc_list.value | 350 |
| apc_list.currency | EUR |
| apc_list.value_usd | 377 |
| apc_paid.value | 350 |
| apc_paid.currency | EUR |
| apc_paid.value_usd | 377 |
| concepts[0].id | https://openalex.org/C2778715743 |
| concepts[0].level | 2 |
| concepts[0].score | 0.6395564675331116 |
| concepts[0].wikidata | https://www.wikidata.org/wiki/Q181802 |
| concepts[0].display_name | Prosthesis |
| concepts[1].id | https://openalex.org/C192562407 |
| concepts[1].level | 0 |
| concepts[1].score | 0.4593499004840851 |
| concepts[1].wikidata | https://www.wikidata.org/wiki/Q228736 |
| concepts[1].display_name | Materials science |
| concepts[2].id | https://openalex.org/C159985019 |
| concepts[2].level | 1 |
| concepts[2].score | 0.328821063041687 |
| concepts[2].wikidata | https://www.wikidata.org/wiki/Q181790 |
| concepts[2].display_name | Composite material |
| concepts[3].id | https://openalex.org/C78519656 |
| concepts[3].level | 1 |
| concepts[3].score | 0.32456961274147034 |
| concepts[3].wikidata | https://www.wikidata.org/wiki/Q101333 |
| concepts[3].display_name | Mechanical engineering |
| concepts[4].id | https://openalex.org/C66938386 |
| concepts[4].level | 1 |
| concepts[4].score | 0.3205481171607971 |
| concepts[4].wikidata | https://www.wikidata.org/wiki/Q633538 |
| concepts[4].display_name | Structural engineering |
| concepts[5].id | https://openalex.org/C41008148 |
| concepts[5].level | 0 |
| concepts[5].score | 0.2969900965690613 |
| concepts[5].wikidata | https://www.wikidata.org/wiki/Q21198 |
| concepts[5].display_name | Computer science |
| concepts[6].id | https://openalex.org/C127413603 |
| concepts[6].level | 0 |
| concepts[6].score | 0.215975821018219 |
| concepts[6].wikidata | https://www.wikidata.org/wiki/Q11023 |
| concepts[6].display_name | Engineering |
| concepts[7].id | https://openalex.org/C154945302 |
| concepts[7].level | 1 |
| concepts[7].score | 0.08575448393821716 |
| concepts[7].wikidata | https://www.wikidata.org/wiki/Q11660 |
| concepts[7].display_name | Artificial intelligence |
| keywords[0].id | https://openalex.org/keywords/prosthesis |
| keywords[0].score | 0.6395564675331116 |
| keywords[0].display_name | Prosthesis |
| keywords[1].id | https://openalex.org/keywords/materials-science |
| keywords[1].score | 0.4593499004840851 |
| keywords[1].display_name | Materials science |
| keywords[2].id | https://openalex.org/keywords/composite-material |
| keywords[2].score | 0.328821063041687 |
| keywords[2].display_name | Composite material |
| keywords[3].id | https://openalex.org/keywords/mechanical-engineering |
| keywords[3].score | 0.32456961274147034 |
| keywords[3].display_name | Mechanical engineering |
| keywords[4].id | https://openalex.org/keywords/structural-engineering |
| keywords[4].score | 0.3205481171607971 |
| keywords[4].display_name | Structural engineering |
| keywords[5].id | https://openalex.org/keywords/computer-science |
| keywords[5].score | 0.2969900965690613 |
| keywords[5].display_name | Computer science |
| keywords[6].id | https://openalex.org/keywords/engineering |
| keywords[6].score | 0.215975821018219 |
| keywords[6].display_name | Engineering |
| keywords[7].id | https://openalex.org/keywords/artificial-intelligence |
| keywords[7].score | 0.08575448393821716 |
| keywords[7].display_name | Artificial intelligence |
| language | en |
| locations[0].id | doi:10.5937/jaes0-55883 |
| locations[0].is_oa | True |
| locations[0].source.id | https://openalex.org/S4210220857 |
| locations[0].source.issn | 1451-4117, 1821-3197 |
| locations[0].source.type | journal |
| locations[0].source.is_oa | True |
| locations[0].source.issn_l | 1451-4117 |
| locations[0].source.is_core | False |
| locations[0].source.is_in_doaj | False |
| locations[0].source.display_name | Istrazivanja i projektovanja za privredu |
| locations[0].source.host_organization | https://openalex.org/P4310321453 |
| locations[0].source.host_organization_name | Faculty of Agronomy in Čačak |
| locations[0].source.host_organization_lineage | https://openalex.org/P4310321453 |
| locations[0].source.host_organization_lineage_names | Faculty of Agronomy in Čačak |
| locations[0].license | cc-by |
| locations[0].pdf_url | https://aseestant.ceon.rs/index.php/jaes/article/download/55883/27508 |
| locations[0].version | publishedVersion |
| locations[0].raw_type | journal-article |
| locations[0].license_id | https://openalex.org/licenses/cc-by |
| locations[0].is_accepted | True |
| locations[0].is_published | True |
| locations[0].raw_source_name | Journal of Applied Engineering Science |
| locations[0].landing_page_url | https://doi.org/10.5937/jaes0-55883 |
| indexed_in | crossref |
| authorships[0].author.id | https://openalex.org/A5094050831 |
| authorships[0].author.orcid | https://orcid.org/0009-0007-5241-7720 |
| authorships[0].author.display_name | Nishant Nikam |
| authorships[0].author_position | first |
| authorships[0].raw_author_name | Nishant Nikam |
| authorships[0].is_corresponding | False |
| authorships[1].author.id | https://openalex.org/A5075179403 |
| authorships[1].author.orcid | https://orcid.org/0000-0003-2374-3854 |
| authorships[1].author.display_name | B. Satish Shenoy |
| authorships[1].author_position | middle |
| authorships[1].raw_author_name | Satish Shenoy B |
| authorships[1].is_corresponding | False |
| authorships[2].author.id | https://openalex.org/A5063495883 |
| authorships[2].author.orcid | https://orcid.org/0000-0001-7010-7186 |
| authorships[2].author.display_name | Laxmikant G. Keni |
| authorships[2].author_position | middle |
| authorships[2].raw_author_name | Laxmikant G Keni |
| authorships[2].is_corresponding | False |
| authorships[3].author.id | https://openalex.org/A5078437053 |
| authorships[3].author.orcid | https://orcid.org/0000-0001-6384-1489 |
| authorships[3].author.display_name | Sawan Shetty |
| authorships[3].author_position | middle |
| authorships[3].raw_author_name | Sawan Shetty |
| authorships[3].is_corresponding | False |
| authorships[4].author.id | https://openalex.org/A5022089203 |
| authorships[4].author.orcid | https://orcid.org/0000-0001-9545-4838 |
| authorships[4].author.display_name | Shyamasunder N Bhat |
| authorships[4].author_position | middle |
| authorships[4].raw_author_name | Shyamasunder Bhat N |
| authorships[4].is_corresponding | False |
| authorships[5].author.id | https://openalex.org/A5008662781 |
| authorships[5].author.orcid | |
| authorships[5].author.display_name | K N Chethan |
| authorships[5].author_position | last |
| authorships[5].raw_author_name | Chethan K N |
| authorships[5].is_corresponding | False |
| has_content.pdf | True |
| has_content.grobid_xml | True |
| is_paratext | False |
| open_access.is_oa | True |
| open_access.oa_url | https://aseestant.ceon.rs/index.php/jaes/article/download/55883/27508 |
| open_access.oa_status | gold |
| open_access.any_repository_has_fulltext | False |
| created_date | 2025-10-10T00:00:00 |
| display_name | Computational analysis of hip prosthesis: Impact of shape and material on mechanical performance |
| has_fulltext | False |
| is_retracted | False |
| updated_date | 2025-11-06T03:46:38.306776 |
| primary_topic.id | https://openalex.org/T10512 |
| primary_topic.field.id | https://openalex.org/fields/27 |
| primary_topic.field.display_name | Medicine |
| primary_topic.score | 0.9990000128746033 |
| primary_topic.domain.id | https://openalex.org/domains/4 |
| primary_topic.domain.display_name | Health Sciences |
| primary_topic.subfield.id | https://openalex.org/subfields/2746 |
| primary_topic.subfield.display_name | Surgery |
| primary_topic.display_name | Orthopaedic implants and arthroplasty |
| related_works | https://openalex.org/W2899084033, https://openalex.org/W4404995717, https://openalex.org/W2016187641, https://openalex.org/W4404725684, https://openalex.org/W4246450666, https://openalex.org/W4388998267, https://openalex.org/W2898370298, https://openalex.org/W2137437058, https://openalex.org/W4408298383, https://openalex.org/W4408578531 |
| cited_by_count | 1 |
| counts_by_year[0].year | 2025 |
| counts_by_year[0].cited_by_count | 1 |
| locations_count | 1 |
| best_oa_location.id | doi:10.5937/jaes0-55883 |
| best_oa_location.is_oa | True |
| best_oa_location.source.id | https://openalex.org/S4210220857 |
| best_oa_location.source.issn | 1451-4117, 1821-3197 |
| best_oa_location.source.type | journal |
| best_oa_location.source.is_oa | True |
| best_oa_location.source.issn_l | 1451-4117 |
| best_oa_location.source.is_core | False |
| best_oa_location.source.is_in_doaj | False |
| best_oa_location.source.display_name | Istrazivanja i projektovanja za privredu |
| best_oa_location.source.host_organization | https://openalex.org/P4310321453 |
| best_oa_location.source.host_organization_name | Faculty of Agronomy in Čačak |
| best_oa_location.source.host_organization_lineage | https://openalex.org/P4310321453 |
| best_oa_location.source.host_organization_lineage_names | Faculty of Agronomy in Čačak |
| best_oa_location.license | cc-by |
| best_oa_location.pdf_url | https://aseestant.ceon.rs/index.php/jaes/article/download/55883/27508 |
| best_oa_location.version | publishedVersion |
| best_oa_location.raw_type | journal-article |
| best_oa_location.license_id | https://openalex.org/licenses/cc-by |
| best_oa_location.is_accepted | True |
| best_oa_location.is_published | True |
| best_oa_location.raw_source_name | Journal of Applied Engineering Science |
| best_oa_location.landing_page_url | https://doi.org/10.5937/jaes0-55883 |
| primary_location.id | doi:10.5937/jaes0-55883 |
| primary_location.is_oa | True |
| primary_location.source.id | https://openalex.org/S4210220857 |
| primary_location.source.issn | 1451-4117, 1821-3197 |
| primary_location.source.type | journal |
| primary_location.source.is_oa | True |
| primary_location.source.issn_l | 1451-4117 |
| primary_location.source.is_core | False |
| primary_location.source.is_in_doaj | False |
| primary_location.source.display_name | Istrazivanja i projektovanja za privredu |
| primary_location.source.host_organization | https://openalex.org/P4310321453 |
| primary_location.source.host_organization_name | Faculty of Agronomy in Čačak |
| primary_location.source.host_organization_lineage | https://openalex.org/P4310321453 |
| primary_location.source.host_organization_lineage_names | Faculty of Agronomy in Čačak |
| primary_location.license | cc-by |
| primary_location.pdf_url | https://aseestant.ceon.rs/index.php/jaes/article/download/55883/27508 |
| primary_location.version | publishedVersion |
| primary_location.raw_type | journal-article |
| primary_location.license_id | https://openalex.org/licenses/cc-by |
| primary_location.is_accepted | True |
| primary_location.is_published | True |
| primary_location.raw_source_name | Journal of Applied Engineering Science |
| primary_location.landing_page_url | https://doi.org/10.5937/jaes0-55883 |
| publication_date | 2025-01-01 |
| publication_year | 2025 |
| referenced_works | https://openalex.org/W4392343443, https://openalex.org/W4376631034, https://openalex.org/W2118686308, https://openalex.org/W2065749233, https://openalex.org/W2103792349, https://openalex.org/W4386891788, https://openalex.org/W2045358834, https://openalex.org/W4307644638, https://openalex.org/W3214074691, https://openalex.org/W2091671527, https://openalex.org/W2623561484, https://openalex.org/W2161748213, https://openalex.org/W4245574556, https://openalex.org/W4376106209, https://openalex.org/W3197933766, https://openalex.org/W4400165077, https://openalex.org/W3002307206, https://openalex.org/W1972539705, https://openalex.org/W2146048218, https://openalex.org/W2468881647, https://openalex.org/W2971710726, https://openalex.org/W2344392591, https://openalex.org/W4213439498 |
| referenced_works_count | 23 |
| abstract_inverted_index.N | 77 |
| abstract_inverted_index.a | 3, 37, 73, 149, 154 |
| abstract_inverted_index.in | 6, 12, 153, 180 |
| abstract_inverted_index.is | 157 |
| abstract_inverted_index.of | 23, 42, 75, 173 |
| abstract_inverted_index.to | 49, 79, 91, 112, 195 |
| abstract_inverted_index.Hip | 0 |
| abstract_inverted_index.MoM | 155 |
| abstract_inverted_index.R2, | 71 |
| abstract_inverted_index.The | 18, 58, 96, 168 |
| abstract_inverted_index.Two | 83 |
| abstract_inverted_index.and | 9, 20, 32, 44, 66, 87, 109, 131, 163, 177, 191 |
| abstract_inverted_index.for | 159 |
| abstract_inverted_index.hip | 15, 46, 182 |
| abstract_inverted_index.its | 29 |
| abstract_inverted_index.the | 24, 120, 171 |
| abstract_inverted_index.von | 106 |
| abstract_inverted_index.11.0 | 65 |
| abstract_inverted_index.2023 | 70 |
| abstract_inverted_index.2300 | 76 |
| abstract_inverted_index.CREO | 64 |
| abstract_inverted_index.CoCr | 123, 151 |
| abstract_inverted_index.This | 34 |
| abstract_inverted_index.load | 74 |
| abstract_inverted_index.over | 142 |
| abstract_inverted_index.pain | 11 |
| abstract_inverted_index.play | 2 |
| abstract_inverted_index.role | 5 |
| abstract_inverted_index.stem | 26, 152 |
| abstract_inverted_index.that | 99, 148 |
| abstract_inverted_index.them | 116 |
| abstract_inverted_index.were | 61 |
| abstract_inverted_index.with | 14, 72 |
| abstract_inverted_index.(MoM) | 137 |
| abstract_inverted_index.Among | 119 |
| abstract_inverted_index.Ansys | 69 |
| abstract_inverted_index.Mises | 107 |
| abstract_inverted_index.These | 145 |
| abstract_inverted_index.joint | 16 |
| abstract_inverted_index.lower | 103 |
| abstract_inverted_index.stems | 48, 60, 101 |
| abstract_inverted_index.study | 35, 169 |
| abstract_inverted_index.their | 51, 93 |
| abstract_inverted_index.total | 104, 181 |
| abstract_inverted_index.under | 54 |
| abstract_inverted_index.using | 63, 68 |
| abstract_inverted_index.(CoCr) | 86 |
| abstract_inverted_index.Future | 184 |
| abstract_inverted_index.assess | 92 |
| abstract_inverted_index.better | 125 |
| abstract_inverted_index.design | 19 |
| abstract_inverted_index.finite | 39 |
| abstract_inverted_index.making | 115 |
| abstract_inverted_index.rates. | 167 |
| abstract_inverted_index.risks. | 134 |
| abstract_inverted_index.should | 186 |
| abstract_inverted_index.showed | 139 |
| abstract_inverted_index.static | 55 |
| abstract_inverted_index.stems, | 114 |
| abstract_inverted_index.strain | 110 |
| abstract_inverted_index.stress | 129 |
| abstract_inverted_index.(MoPE). | 144 |
| abstract_inverted_index.applied | 78 |
| abstract_inverted_index.crucial | 4 |
| abstract_inverted_index.designs | 194 |
| abstract_inverted_index.dynamic | 188 |
| abstract_inverted_index.element | 40 |
| abstract_inverted_index.enhance | 196 |
| abstract_inverted_index.explore | 187 |
| abstract_inverted_index.failure | 133 |
| abstract_inverted_index.implant | 25, 47, 59, 161, 175, 193 |
| abstract_inverted_index.loading | 56, 189 |
| abstract_inverted_index.modeled | 62 |
| abstract_inverted_index.optimal | 158 |
| abstract_inverted_index.results | 97 |
| abstract_inverted_index.stress, | 108 |
| abstract_inverted_index.suggest | 147 |
| abstract_inverted_index.surgery | 166 |
| abstract_inverted_index.Chromium | 85 |
| abstract_inverted_index.analysed | 67 |
| abstract_inverted_index.analysis | 41 |
| abstract_inverted_index.circular | 43, 113 |
| abstract_inverted_index.clinical | 197 |
| abstract_inverted_index.compared | 111 |
| abstract_inverted_index.enhanced | 140 |
| abstract_inverted_index.evaluate | 50 |
| abstract_inverted_index.findings | 146 |
| abstract_inverted_index.further. | 199 |
| abstract_inverted_index.geometry | 176 |
| abstract_inverted_index.implants | 1 |
| abstract_inverted_index.indicate | 98 |
| abstract_inverted_index.material | 21, 178 |
| abstract_inverted_index.mobility | 8 |
| abstract_inverted_index.outcomes | 198 |
| abstract_inverted_index.patients | 13 |
| abstract_inverted_index.presents | 36 |
| abstract_inverted_index.reducing | 10, 128, 164 |
| abstract_inverted_index.research | 185 |
| abstract_inverted_index.revision | 165 |
| abstract_inverted_index.simulate | 80 |
| abstract_inverted_index.Ti-6Al-4V | 88 |
| abstract_inverted_index.analysed, | 122 |
| abstract_inverted_index.behaviour | 53 |
| abstract_inverted_index.exhibited | 102 |
| abstract_inverted_index.improving | 160 |
| abstract_inverted_index.influence | 28 |
| abstract_inverted_index.longevity | 162 |
| abstract_inverted_index.materials | 121 |
| abstract_inverted_index.optimized | 174 |
| abstract_inverted_index.potential | 132 |
| abstract_inverted_index.restoring | 7 |
| abstract_inverted_index.selection | 22, 179 |
| abstract_inverted_index.superior. | 118 |
| abstract_inverted_index.conditions | 190 |
| abstract_inverted_index.considered | 90 |
| abstract_inverted_index.disorders. | 17 |
| abstract_inverted_index.durability | 141 |
| abstract_inverted_index.importance | 172 |
| abstract_inverted_index.longevity. | 33 |
| abstract_inverted_index.mechanical | 30, 94, 126 |
| abstract_inverted_index.real-world | 81 |
| abstract_inverted_index.structural | 52 |
| abstract_inverted_index.alloys-were | 89 |
| abstract_inverted_index.comparative | 38 |
| abstract_inverted_index.conditions. | 57, 82 |
| abstract_inverted_index.performance | 31 |
| abstract_inverted_index.properties. | 95 |
| abstract_inverted_index.rectangular | 45, 100, 150 |
| abstract_inverted_index.underscores | 170 |
| abstract_inverted_index.deformation, | 105 |
| abstract_inverted_index.demonstrated | 124 |
| abstract_inverted_index.performance, | 127 |
| abstract_inverted_index.structurally | 117 |
| abstract_inverted_index.Additionally, | 135 |
| abstract_inverted_index.arthroplasty. | 183 |
| abstract_inverted_index.concentration | 130 |
| abstract_inverted_index.configuration | 156 |
| abstract_inverted_index.significantly | 27 |
| abstract_inverted_index.configurations | 138 |
| abstract_inverted_index.metal-on-metal | 136 |
| abstract_inverted_index.materials-Cobalt | 84 |
| abstract_inverted_index.patient-specific | 192 |
| abstract_inverted_index.metal-on-polyethylene | 143 |
| cited_by_percentile_year.max | 95 |
| cited_by_percentile_year.min | 91 |
| countries_distinct_count | 0 |
| institutions_distinct_count | 6 |
| citation_normalized_percentile.value | 0.88367892 |
| citation_normalized_percentile.is_in_top_1_percent | False |
| citation_normalized_percentile.is_in_top_10_percent | True |