Probing Aqueous Ions with Non-local Auger Relaxation - data Article Swipe
YOU?
·
· 2022
· Open Access
·
· DOI: https://doi.org/10.5281/zenodo.7289832
· OA: W4393727227
Data set pertaining to the article "Probing aqueous ions with non-local Auger relaxation" | Physical Chemistry Chemical Physics, <strong>24</strong>, 8661-8671 (2022). doi: 10.1039/D2CP00227B. Files with extension .h5 are hdf5-files structured according to the NeXus standard v2022.06, see<br> https://www.nexusformat.org/<br> https://fairmat-experimental.github.io/nexus-fairmat-proposal/50433d9039b3f33299bab338998acb5335cd8951/mpes-structure.html<br> NeXus data files can be opened with any software capable of opening hdf5-files. The following viewers are adapted to the specifics of the NeXus data format:<br> * nexpy (distributed with python)<br> * https://h5web.panosc.eu/h5wasm (web-based NeXus viewer maintained by the European Photon and Neutron Open Science Cloud-consortium) In each NeXus file-entry, two types of spectra are shown:<br> 1. Sweep-averaged spectra integrated over the non-dispersive coordinate of our detector ('data').<br> 2. As-measured data ('raw'). <br> The following files are provided: Photoemission data pertaining to ICD measurements, and to 1s spectra shown in Supplementary Fig. S2 (Na, Al):<br> ICD_data.na.h5<br> ICD_data.mg.h5<br> ICD_data.al.h5<br> Photon energy corrections are applied as explained in the article and Supplementary Material, kinetic energy correction is applied to the dataset 'data'. Calibration data:<br> calibration_data.p04.h5 : Mostly photon energy calibration for ICD spectra.<br> calibration_data.bessy.mg.h5 : Spectra measured at BESSY for MgCl2 Mg 1s binding energy calibration.<br> calibration_data.bessy.al.h5 : Spectra measured at BESSY for AlCl3 Al 1s binding energy calibration.<br> calibration_data.p04.add.h5 : Additional spectra for cross-checking binding energy calibration, measured at DESY P04.<br> All calibration spectra are included as-measured. A binding energy axis, shown for some spectra, is derived as implied from the uncalibrated photon and kinetic energies. Contact: Uwe Hergenhahn, [email protected] . v2 release notes<br> A number of minor errors in the metadata and .hdf5-structure of the v1 dataset were corrected. The data themselves are unaffected.<br> * Names of NXdata-groups now agree to NXmpes naming-convention,<br> * incorrect value of photon energy correction of Al ICD data fixed (ICD_data.al.h5),<br> * proposal numbers added to metadata,<br> * measurements on pure water solution designated as calibration.