Quantification of [99mTc]Tc-HDP bone SPECT/CT: can we improve the body weight based standardized uptake value with a more robust normalization? Article Swipe
Related Concepts
Medicine
Nuclear medicine
Hounsfield scale
Orthopedic surgery
Linear regression
Standardized uptake value
Correlation
Normalization (sociology)
Lumbar vertebrae
Cardiac imaging
Lumbar
Radiology
Computed tomography
Positron emission tomography
Surgery
Mathematics
Statistics
Sociology
Anthropology
Geometry
Tiberiu Damian
,
Noel Spielhofer
,
Jakob Heimer
,
Alexander Sauter
,
Cristina Popescu
,
Daniel Hausmann
,
Jason L. Manser
,
Karim Eid
,
R. Huch
,
Irene A. Burger
·
YOU?
·
· 2024
· Open Access
·
· DOI: https://doi.org/10.1186/s13550-024-01167-6
· OA: W4404524530
YOU?
·
· 2024
· Open Access
·
· DOI: https://doi.org/10.1186/s13550-024-01167-6
· OA: W4404524530
Using an age, bone density and weight-based normalization significantly decreased the interindividual variability of normal uptake on quantitative SPECT/CT compared to the regularly used BW adjusted SUV<sub>BW</sub>. However, a generalized normalization is difficult in the presence of strong patient effects, not attributable to the measured clinical variables.