Richard Laforest
YOU?
Author Swipe
View article: Evaluation of [ <sup>11</sup> C]CS1P1 in Healthy Young and Older Adults
Evaluation of [ <sup>11</sup> C]CS1P1 in Healthy Young and Older Adults Open
In this study, we have established a quantitative 11C]CS1P1 PET processing approach by using a 2-tissue compartment model and imaging-derived input function with population metabolite correction. [11C]CS1P1 PET reflec…
View article: Radiation dosimetry and fasting-dependent hepatobiliary clearance of the VAChT-specific PET radioligand 18F-VAT in humans
Radiation dosimetry and fasting-dependent hepatobiliary clearance of the VAChT-specific PET radioligand 18F-VAT in humans Open
Background The vesicular acetylcholine transporter ligand (-)-(1-((2R,3R)-8-(2-[(18)F]fluoro-ethoxy)-3-hydroxy-1,2,3,4-tetrahydronaphthalen-2-yl)piperidin-4-yl)(4-fluorophenyl)-methanone ( 18 F -VAT) enables positron emission tomography PE…
View article: Development and in silico imaging trial evaluation of a deep-learning-based transmission-less attenuation compensation method for DaT SPECT
Development and in silico imaging trial evaluation of a deep-learning-based transmission-less attenuation compensation method for DaT SPECT Open
Quantitative measures of dopamine transporter (DaT) uptake in caudate, putamen, and globus pallidus derived from DaT-single-photon emission computed tomography (SPECT) images are being investigated as biomarkers to diagnose, assess disease…
View article: Radiation dosimetry of [11C]TZ1964B as determined by whole-body PET imaging of nonhuman primates
Radiation dosimetry of [11C]TZ1964B as determined by whole-body PET imaging of nonhuman primates Open
View article: Chemokine Receptor 2 Is a Theranostic Biomarker for Abdominal Aortic Aneurysms
Chemokine Receptor 2 Is a Theranostic Biomarker for Abdominal Aortic Aneurysms Open
View article: Pilot first-in-human CCR2 PET/CT to detect abdominal aortic aneurysm wall instability
Pilot first-in-human CCR2 PET/CT to detect abdominal aortic aneurysm wall instability Open
Objective: In a pilot first-in-human study, we aimed to evaluate the feasibility of Positron Emission Tomography/Computed Tomography (PET/CT) imaging of C-C chemokine receptor type 2 (CCR2) to aid in the diagnosis of abdominal aorti…
View article: Addressing lung truncation in 99mTc-MAA SPECT/CT for 90Y microsphere radioembolization treatment planning
Addressing lung truncation in 99mTc-MAA SPECT/CT for 90Y microsphere radioembolization treatment planning Open
LSF and LMD can be estimated for 90Y radioembolization using truncated lung coverage data in MAA-SPECT/CT. Empirical models to predict lung counts at full lung coverage produced LSF and LMD estimates with minimal bias and uncert…
View article: Radiation Dosimetry and Fasting-Dependent Hepatobiliary Clearance of the VAChT- Specific PET radioligand 18F-VAT in Humans
Radiation Dosimetry and Fasting-Dependent Hepatobiliary Clearance of the VAChT- Specific PET radioligand 18F-VAT in Humans Open
Background The vesicular acetylcholine transporter ligand (-)-(1-((2R,3R)-8-(2-[(18)F]fluoro-ethoxy)-3-hydroxy-1,2,3,4-tetrahydronaphthalen-2-yl)piperidin-4-yl)(4-fluorophenyl)-methanone (18F -VAT) enables positron emission tomo…
View article: CTLESS: A Scatter-Window Projection and Deep Learning-Based Transmission-Less Attenuation Compensation Method for Myocardial Perfusion SPECT
CTLESS: A Scatter-Window Projection and Deep Learning-Based Transmission-Less Attenuation Compensation Method for Myocardial Perfusion SPECT Open
Attenuation compensation (AC), while being beneficial for visual-interpretation tasks in myocardial perfusion imaging (MPI) by SPECT, typically requires the availability of a separate X-ray CT component, leading to additional radiation dos…
View article: Assessment of lesion insertion tool in pelvis PET/MR data with applications to attenuation correction method development
Assessment of lesion insertion tool in pelvis PET/MR data with applications to attenuation correction method development Open
Background In modern positron emission tomography (PET) with multi‐modality imaging (e.g., PET/CT and PET/MR), the attenuation correction (AC) is the single largest correction factor for image reconstruction. One way to assess AC methods a…
View article: Quantitative Assessments of Tumor Activity in a General Oncologic PET/CT Population: Which Metric Minimizes Tracer Uptake Time Dependence?
Quantitative Assessments of Tumor Activity in a General Oncologic PET/CT Population: Which Metric Minimizes Tracer Uptake Time Dependence? Open
In oncologic PET, the SUV and standardized uptake ratio (SUR) of a viable tumor generally increase during the postinjection period. In contrast, the net influx rate (Ki ), which is derived from dynamic PET data, should re…
View article: FAST (fast analytical simulator of tracer)-PET: an accurate and efficient PET analytical simulation tool
FAST (fast analytical simulator of tracer)-PET: an accurate and efficient PET analytical simulation tool Open
Objective. Simulation of positron emission tomography (PET) images is an essential tool in the development and validation of quantitative imaging workflows and advanced image processing pipelines. Existing Monte Carlo or analytical PET sim…
View article: Joint Regional Uptake Quantification of Thorium-227 and Radium-223 Using a Multiple-Energy-Window Projection-Domain Quantitative SPECT Method
Joint Regional Uptake Quantification of Thorium-227 and Radium-223 Using a Multiple-Energy-Window Projection-Domain Quantitative SPECT Method Open
Thorium-227 ( )-based -particle radiopharmaceutical therapies ( -RPTs) are currently being investigated in several clinical and pre-clinical studies. After administration, decays to , another -particle-emitting isotope, which redistributes…
View article: Deep learning generation of preclinical positron emission tomography (PET) images from low‐count PET with task‐based performance assessment
Deep learning generation of preclinical positron emission tomography (PET) images from low‐count PET with task‐based performance assessment Open
Background Preclinical low‐count positron emission tomography (LC‐PET) imaging offers numerous advantages such as facilitating imaging logistics, enabling longitudinal studies of long‐ and short‐lived isotopes as well as increasing scanner…
View article: Patlak Slope versus Standardized Uptake Value Image Quality in an Oncologic PET/CT Population: A Prospective Cross-Sectional Study
Patlak Slope versus Standardized Uptake Value Image Quality in an Oncologic PET/CT Population: A Prospective Cross-Sectional Study Open
Patlak slope (PS) images have the potential to improve lesion conspicuity compared with standardized uptake value (SUV) images but may be more artifact-prone. This study compared PS versus SUV image quality and hepatic tumor-to-background …
View article: #27. First-in-human evaluation of safety and dosimetry of 64Cu-LLP2A for PET imaging
#27. First-in-human evaluation of safety and dosimetry of 64Cu-LLP2A for PET imaging Open
View article: DEMIST: A Deep-Learning-Based Detection-Task-Specific Denoising Approach for Myocardial Perfusion SPECT
DEMIST: A Deep-Learning-Based Detection-Task-Specific Denoising Approach for Myocardial Perfusion SPECT Open
There is an important need for methods to process myocardial perfusion imaging (MPI) single-photon emission computed tomography (SPECT) images acquired at lower-radiation dose and/or acquisition time such that the processed images improve …
View article: MIRD Pamphlet No. 29: MIRDy90—A<sup>90</sup>Y Research Microsphere Dosimetry Tool
MIRD Pamphlet No. 29: MIRDy90—A<sup>90</sup>Y Research Microsphere Dosimetry Tool Open
90Y-microsphere radioembolization has become a well-established treatment option for liver malignancies and is one of the first U.S. Food and Drug Administration-approved unsealed radionuclide brachytherapy devices to incorporat…
View article: Test-Retest Repeatability of Patlak Slopes versus Standardized Uptake Values for Hypermetabolic Lesions and Normal Organs in an Oncologic PET/CT Population
Test-Retest Repeatability of Patlak Slopes versus Standardized Uptake Values for Hypermetabolic Lesions and Normal Organs in an Oncologic PET/CT Population Open
Purpose: We aimed to determine the test-retest repeatability of quantitative metrics based on the Patlak slope (PS) versus the standardized uptake value (SUV) among lesions and normal organs on oncologic [18F]FDG-PET/CT. Procedu…
View article: Very-low-density lipoprotein triglyceride and free fatty acid plasma kinetics in women with high or low brown adipose tissue volume and overweight/obesity
Very-low-density lipoprotein triglyceride and free fatty acid plasma kinetics in women with high or low brown adipose tissue volume and overweight/obesity Open
Although a high amount of brown adipose tissue (BAT) is associated with low plasma triglyceride concentration, the mechanism responsible for this relationship in people is not clear. Here, we evaluate the interrelationships among BAT, very…
View article: An automatic pipeline for PET/MRI attenuation correction validation in the brain
An automatic pipeline for PET/MRI attenuation correction validation in the brain Open
View article: Chemokine Receptor 2 Is A Theranostic Biomarker for Abdominal Aortic Aneurysms
Chemokine Receptor 2 Is A Theranostic Biomarker for Abdominal Aortic Aneurysms Open
Abdominal aortic aneurysm (AAA) is a degenerative vascular disease impacting aging populations with a high mortality upon rupture. There are no effective medical therapies to prevent AAA expansion and rupture. We previously demonstrated th…
View article: DEMIST: A deep-learning-based task-specific denoising approach for myocardial perfusion SPECT.
DEMIST: A deep-learning-based task-specific denoising approach for myocardial perfusion SPECT. Open
There is an important need for methods to process myocardial perfusion imaging (MPI) SPECT images acquired at lower radiation dose and/or acquisition time such that the processed images improve observer performance on the clinical task of …
View article: CCR2 imaging in human ST-segment elevation myocardial infarction
CCR2 imaging in human ST-segment elevation myocardial infarction Open
View article: A list-mode multi-energy window low-count SPECT reconstruction method for isotopes with multiple emission peaks
A list-mode multi-energy window low-count SPECT reconstruction method for isotopes with multiple emission peaks Open
View article: SNMMI Procedure Standard/EANM Practice Guideline for Palliative Nuclear Medicine Therapies of Bone Metastases
SNMMI Procedure Standard/EANM Practice Guideline for Palliative Nuclear Medicine Therapies of Bone Metastases Open
The Society of Nuclear Medicine and Molecular Imaging (SNMMI) is an international scientific and professional organization founded in 1954 to promote the science, technology, and practical application of nuclear medicine. The European Asso…
View article: A list-mode multi-energy window low-count SPECT reconstruction method for isotopes with multiple emission peaks
A list-mode multi-energy window low-count SPECT reconstruction method for isotopes with multiple emission peaks Open
SPECT provides a mechanism to perform absorbed-dose quantification tasks for $α$-particle radiopharmaceutical therapies ($α$-RPTs). However, quantitative SPECT for $α$-RPT is challenging due to the low number of detected counts, the comple…
View article: Joint regional uptake quantification of Thorium-227 and Radium-223 using a multiple-energy-window projection-domain quantitative SPECT method
Joint regional uptake quantification of Thorium-227 and Radium-223 using a multiple-energy-window projection-domain quantitative SPECT method Open
Thorium-227-based alpha-particle radiopharmaceutical therapies (α-RPTs) are being investigated in several clinical and pre-clinical studies. After administration, Thorium-227 decays to Radium-223, another alpha-particle-emitting isotope, w…
View article: An automatic pipeline for PET/MRI attenuation correction validation in the brain
An automatic pipeline for PET/MRI attenuation correction validation in the brain Open
Purpose PET/MRI quantitative accuracy for neurological applications is challenging due to accuracy of the PET attenuation correction. In this work, we proposed and evaluated an automatic pipeline for assessing the quantitative accuracy of …
View article: Co-Clinical Imaging Metadata Information (CIMI) for Cancer Research to Promote Open Science, Standardization, and Reproducibility in Preclinical Imaging
Co-Clinical Imaging Metadata Information (CIMI) for Cancer Research to Promote Open Science, Standardization, and Reproducibility in Preclinical Imaging Open
Preclinical imaging is a critical component in translational research with significant complexities in workflow and site differences in deployment. Importantly, the National Cancer Institute’s (NCI) precision medicine initiative emphasizes…