View article: Time-resolved biological effective dose distributions in stereotactic radiosurgery for vestibular schwannomas: a comparative analysis between two dedicated stereotactic radiosurgery systems
Time-resolved biological effective dose distributions in stereotactic radiosurgery for vestibular schwannomas: a comparative analysis between two dedicated stereotactic radiosurgery systems Open
Objective. Stereotactic radiosurgery (SRS) delivered using a step-and-shoot approach, using either isocentric or non-isocentric radiation beams, typically results in distinct treatment delivery patterns across different SRS systems, reflec…
View article: Exploring long-term outcomes following CyberKnife robotic radiosurgery for trigeminal neuralgia
Exploring long-term outcomes following CyberKnife robotic radiosurgery for trigeminal neuralgia Open
View article: On the effect of dose delivery temporal domain on the biological effectiveness of central nervous system CyberKnife radiosurgery applications: theoretical assessment using the concept of biologically effective dose
On the effect of dose delivery temporal domain on the biological effectiveness of central nervous system CyberKnife radiosurgery applications: theoretical assessment using the concept of biologically effective dose Open
Objective: The diversity in technical configuration between clinically available radiosurgery systems, results in accordingly diverse treatment times for the same physical dose prescription, spanning from several min to more than 1 h. This…
View article: Dose rate mapping and radiobiological assessment of helical tomotherapy prostate and head and neck treatments
Dose rate mapping and radiobiological assessment of helical tomotherapy prostate and head and neck treatments Open
View article: [P264] Time resolved dose rate distributions in radiosurgery and their impact on biological effectiveness of treatment
[P264] Time resolved dose rate distributions in radiosurgery and their impact on biological effectiveness of treatment Open
View article: On the total system error of a robotic radiosurgery system: phantom measurements, clinical evaluation and long-term analysis
On the total system error of a robotic radiosurgery system: phantom measurements, clinical evaluation and long-term analysis Open
The total system error (TSE) of a CyberKnife® system was measured using two phantom-based methods and one patient-based method. The standard radiochromic film (RCF) end-to-end (E2E) test using an anthropomorphic head and neck ph…
View article: Review and comparison of geometric distortion correction schemes in MR images used in stereotactic radiosurgery applications
Review and comparison of geometric distortion correction schemes in MR images used in stereotactic radiosurgery applications Open
In Stereotactic Radiosurgery (SRS), MR-images are widely used for target localization and delineation in order to take advantage of the superior soft tissue contrast they exhibit. However, spatial dose delivery accuracy may be deteriorated…
View article: MRI-Related Geometric Distortions in Stereotactic Radiotherapy Treatment Planning: Evaluation and Dosimetric Impact
MRI-Related Geometric Distortions in Stereotactic Radiotherapy Treatment Planning: Evaluation and Dosimetric Impact Open
In view of their superior soft tissue contrast compared to computed tomography, magnetic resonance images are commonly involved in stereotactic radiosurgery/radiotherapy applications for target delineation purposes. It is known, however, t…
View article: EP-1438: Experimental determination of correction factors for reference dosimetry in Gamma Knife Perfexion
EP-1438: Experimental determination of correction factors for reference dosimetry in Gamma Knife Perfexion Open