Abdul Multi
YOU?
Author Swipe
View article: TWO-AXIS SOLAR PANEL TRACKING DEVICE PROTOTYPE WITH IOT-BASED MONITORING
TWO-AXIS SOLAR PANEL TRACKING DEVICE PROTOTYPE WITH IOT-BASED MONITORING Open
The aim of this project is to develop a dual-axis solar tracker equipped with an IoT monitoring system with the BLYNK platform using Arduino. Overall, solar energy refers to technologies that generate power from sunlight. The utilization o…
View article: Application Design of A Multiple Power Source Monitoring System Based On The Internet Of Things (IOT)
Application Design of A Multiple Power Source Monitoring System Based On The Internet Of Things (IOT) Open
At the present time, technology is developing rapidly in various scientific fields. People continue to develop and research the latest technologies to make human life easier. One of them is in the field of IoT (Internet of Things) technolo…
View article: Post Operational Optimization of Adaptive Overload Shedding Protection in the Bali Island Sub-system using the ADS Simulation
Post Operational Optimization of Adaptive Overload Shedding Protection in the Bali Island Sub-system using the ADS Simulation Open
The Bali electrical network sub system is supported by the Java-Bali power transfer assisted by the Bali power generation. Most of these power plants are not economical, so the Java-Bali power transfer is prioritized. If an island operatio…
View article: Supercapacitor Implementation To Prototype Energy Storage System Optimizer in PV System
Supercapacitor Implementation To Prototype Energy Storage System Optimizer in PV System Open
This research aims to create a prototype of an energy storage optimizer in a PV system using a supercapacitor in combination with batteries. The purpose of adding supercapacitors in this prototype is to maintain battery usage when there is…
View article: Rancang Bangun Real Time Monitoring & Controlling Infant Incubator Dengan Tilt Stabilizer Untuk Mengurangi Kemiringan Saat Pemindahan Bayi Menggunakan Rasberry PI Berbasis IOT
Rancang Bangun Real Time Monitoring & Controlling Infant Incubator Dengan Tilt Stabilizer Untuk Mengurangi Kemiringan Saat Pemindahan Bayi Menggunakan Rasberry PI Berbasis IOT Open
The rapid advancement of technology requires innovation to introduce superior features compared to existing technologies, including in the field of healthcare, such as infant incubators. Currently, there is no infant incubator that incorpo…
View article: Estimasi Sensor Temperatur Udara Automatic Weather Station Menggunakan Algoritma Hybrid Arima-MLP
Estimasi Sensor Temperatur Udara Automatic Weather Station Menggunakan Algoritma Hybrid Arima-MLP Open
Air temperature sensor is installed in an enclosure with a relative humidity sensor at a height of 1.25 meters from the ground. This sensor is routinely calibrated every year through a field comparison mechanism using standard portable. Ho…
View article: Rancang Bangun Sistem Pemantauan dan Pengendali Kualitas Udara Pada Aplikasi Welding Habitat Proses Welding Pipeline Sistem Dengan Data Logger
Rancang Bangun Sistem Pemantauan dan Pengendali Kualitas Udara Pada Aplikasi Welding Habitat Proses Welding Pipeline Sistem Dengan Data Logger Open
Air Quality Monitoring and Control System is a method of monitoring and controlling air quality in an area or place where air contamination may occur in an activity or work. In this case, the Air Quality Monitoring and Control System is ap…
View article: Design and Development of Real-Time Monitoring & Controlling Infant Incubator with Tilt Stabilizer Using Raspberry Pi Remotely Controlled via PC and Smartphone to Reduce Tilt during Baby Transfer
Design and Development of Real-Time Monitoring & Controlling Infant Incubator with Tilt Stabilizer Using Raspberry Pi Remotely Controlled via PC and Smartphone to Reduce Tilt during Baby Transfer Open
This research aims to Design and Development of Real-Time Monitoring & Controlling Infant Incubator with Tilt Stabilizer Using Raspberry Pi Remotely Controlled via PC and Smartphone to Reduce Tilt during Baby Transfer. An experimental appr…
View article: Performance Analysis of Extraction Condensing Turbine - Unit 1 at Pltu X, Bekasi, West Java
Performance Analysis of Extraction Condensing Turbine - Unit 1 at Pltu X, Bekasi, West Java Open
In 2014, Cikarang Listrindo Energy built a steam power plant in Babelan to participate in the government programs. In April 2017, Unit 1 of PLTU Babelan has been operated. After the plant has been in operation for 4 months, the plant will …
View article: Analisis Otomatisasi Kalibrator Tekanan Udara Portabel dengan Pengontrol PID dengan Metode Ziegler-Nichols dan Åström–Hägglund
Analisis Otomatisasi Kalibrator Tekanan Udara Portabel dengan Pengontrol PID dengan Metode Ziegler-Nichols dan Åström–Hägglund Open
Atmospheric pressure is one of the weather parameters that have an important role in meteorological services, especially inflight transportation. Atmospheric pressure sensors must be calibrated regularly to ensure the measurement results. …
View article: Network Metadata (NETTA) : Sistem Monitoring Jaringan Dan Metadata UPT BMKG Dengan Notifikasi Berbasis Telegram
Network Metadata (NETTA) : Sistem Monitoring Jaringan Dan Metadata UPT BMKG Dengan Notifikasi Berbasis Telegram Open
BMKG has a role to disseminate geo-hydrometeorological information in the fields of Meteorology, Climatology and Geophysics. The dissemination process requires data from BMKG operational equipment spread across 183 Technical Implementation…
View article: Rain Attenuation Analysis On VSAT KU-BAND Frequency Meteorological Station of Mopah Merauke
Rain Attenuation Analysis On VSAT KU-BAND Frequency Meteorological Station of Mopah Merauke Open
BMKG is one of the government agencies that provides Meteorological, Climatological, and Geophysic observation data, sent from each Work Unit or Site Sensor. One of the communication media used is VSAT. The Ku-band channel is one of the fr…
View article: ANALISIS PENGUKURAN TANGEN DELTA PADA BAHAN ISOLASI GENERATOR
ANALISIS PENGUKURAN TANGEN DELTA PADA BAHAN ISOLASI GENERATOR Open
An ideal insulation is equivalent to an ideal capacitor which only stores electrical energy and does not dissipate it. In fact, when a potential difference occurs in the insulation, the polar molecules in it will move and rub together cont…
View article: ANALISA PROTEKSI OVER CURRENT RELAY (OCR) DAN GROUND FAULT RELAY (GFR) PADA TRANSFORMATOR DAYA GARDU INDUK
ANALISA PROTEKSI OVER CURRENT RELAY (OCR) DAN GROUND FAULT RELAY (GFR) PADA TRANSFORMATOR DAYA GARDU INDUK Open
In the electric power distribution system, the power transformer is an equipment plays an important role in a substation. In a distribution system, a fault cannot be predicted. This fault can be in the form of a 3-phase, 2-phase, or 1-phas…
View article: STUDY OF THE INFLUENCE OF DISTANCE RELAY SETTING ON AIR LINE HIGH VOLTAGE 150 KV AGAINST HVCRC WIRE 1x310 mm² and ACCC 1x310 mm²
STUDY OF THE INFLUENCE OF DISTANCE RELAY SETTING ON AIR LINE HIGH VOLTAGE 150 KV AGAINST HVCRC WIRE 1x310 mm² and ACCC 1x310 mm² Open
The faults Overhead line is generally caused by short circuit, overload, lightning surge, and tree. Distance relay is one of the protection equipments over the overhead line, and as the main protection by measuring fault impedance magnitud…
View article: Performance of AFWR Synchronous Motor as Changing from AFWR Synchronous Generator
Performance of AFWR Synchronous Motor as Changing from AFWR Synchronous Generator Open
The tests should be performed for the three phase synchronous generator of Axial Flux Wound Rotor (AFWR) which has been planned and constructed. The tests are also performed for the motor deriving from that AFWR generator. The behavior of …
View article: Leak Current Monitoring System On The Ground Cables Medium Voltage Transformer 150/20 kV
Leak Current Monitoring System On The Ground Cables Medium Voltage Transformer 150/20 kV Open
On January, 2017 there had been fault trip at PMT 150/20 kV transformer in Jatirangon substation. For fault detection, that rele differential phase T and REF 20 kV have worked to detect this fault. The resulted impact of this fault is Powe…