Aleksandra Lelević
YOU?
Author Swipe
View article: Quantitative performance of the reverse fill/flush flow modulation in the conditions when the second gas chromatography column outlet pressure is not equal to the atmospheric pressure
Quantitative performance of the reverse fill/flush flow modulation in the conditions when the second gas chromatography column outlet pressure is not equal to the atmospheric pressure Open
Reverse fill/flush flow modulation is an effective approach for peak modulation in comprehensive two-dimensional chromatography, and several home-made or commercial solutions are currently available to users. In terms of configuration, sys…
View article: Solid-State NMR Investigation of Cold-Flow Properties of Hydrotreated Vegetable Oils and Their Blends with Petroleum Diesels
Solid-State NMR Investigation of Cold-Flow Properties of Hydrotreated Vegetable Oils and Their Blends with Petroleum Diesels Open
View article: Score Function for the Optimization of the Performance of Forward Fill/Flush Differential Flow Modulation for Comprehensive Two-Dimensional Gas Chromatography
Score Function for the Optimization of the Performance of Forward Fill/Flush Differential Flow Modulation for Comprehensive Two-Dimensional Gas Chromatography Open
Modulation is the key element of the comprehensive 2D gas chromatography separation. Forward fill/flush flow modulation is cost effective, robust and suitable for analysis of a wide range of samples. Even though this modulation system is w…
View article: Score function for the optimization of the performance of forward fill/flush differential flow modulation for comprehensive two-dimensional gas chromatography
Score function for the optimization of the performance of forward fill/flush differential flow modulation for comprehensive two-dimensional gas chromatography Open
Modulation is the key element of the comprehensive two-dimensional gas chromatography separation. Forward fill/flush flow modulation is cost effective, robust and suitable for analysis of a wide range of samples. Even though this modulatio…
View article: Facilitating method development for reverse fill/flush flow modulation by using a tunable auxiliary pressure source instead of a fixed bleed capillary
Facilitating method development for reverse fill/flush flow modulation by using a tunable auxiliary pressure source instead of a fixed bleed capillary Open
The conventional reverse fill/flush flow modulation for comprehensive two-dimensional gas chromatography requires a bleed capillary column to be connected to the outlet of the modulator channel. The purpose of this capillary, that does not…
View article: plug im ! software for comprehensive two-dimensional gas chromatography with vacuum ultraviolet detection – A tutorial
plug im ! software for comprehensive two-dimensional gas chromatography with vacuum ultraviolet detection – A tutorial Open
View article: Quantification of Hydrocarbons in Gas Oils by GC×GC-VUV: Comparison with Other Techniques
Quantification of Hydrocarbons in Gas Oils by GC×GC-VUV: Comparison with Other Techniques Open
International audience
View article: Co-processing bio-liquids with vacuum gasoil through hydrocracking
Co-processing bio-liquids with vacuum gasoil through hydrocracking Open
View article: Advanced data preprocessing for comprehensive two‐dimensional gas chromatography with vacuum ultraviolet spectroscopy detection
Advanced data preprocessing for comprehensive two‐dimensional gas chromatography with vacuum ultraviolet spectroscopy detection Open
Comprehensive two‐dimensional gas chromatography with vacuum ultraviolet detection results in sizable data for which noise and baseline drift ought to be corrected. As the data is acquired from multiple channels, preprocessing steps have t…
View article: Quantitative Analysis of Hydrocarbons in Gas Oils by Two-Dimensional Comprehensive Gas Chromatography with Vacuum Ultraviolet Detection
Quantitative Analysis of Hydrocarbons in Gas Oils by Two-Dimensional Comprehensive Gas Chromatography with Vacuum Ultraviolet Detection Open
International audience
View article: Determination of vacuum ultraviolet detector response factors by hyphenation with two‐dimensional comprehensive gas chromatography with flame ionization detection
Determination of vacuum ultraviolet detector response factors by hyphenation with two‐dimensional comprehensive gas chromatography with flame ionization detection Open
Two‐dimensional comprehensive gas chromatography is an established technique, employed for the characterization of complex samples. Broadband vacuum ultraviolet absorption spectroscopy detection has recently attracted a lot of attention as…
View article: Quantitative performance of forward fill/flush differential flow modulation for comprehensive two-dimensional gas chromatography
Quantitative performance of forward fill/flush differential flow modulation for comprehensive two-dimensional gas chromatography Open
View article: Gas chromatography vacuum ultraviolet spectroscopy: A review
Gas chromatography vacuum ultraviolet spectroscopy: A review Open
Accelerated technological progress and increased complexity of interrogated matrices imposes a demand for fast, powerful, and resolutive analysis techniques. Gas chromatography has been for a long time a ‘go‐to’ technique for the analysis …
View article: Electrodeposition of Ni P composite coatings: A review
Electrodeposition of Ni P composite coatings: A review Open