Anssi J. Mäkynen
YOU?
Author Swipe
View article: Field measurements of icing parameters and their application towards ice load maps: An overview
Field measurements of icing parameters and their application towards ice load maps: An overview Open
View article: In situ cloud surface measurements dataset from four cloud spectrometers during the Pallas Cloud Experiment (PaCE) 2022
In situ cloud surface measurements dataset from four cloud spectrometers during the Pallas Cloud Experiment (PaCE) 2022 Open
This data paper presents an overview of the cloud spectrometers deployed during the Pallas Cloud Experiment (PaCE) in autumn 2022, a coordinated measurement campaign in the Finnish subarctic that took place between September 12th and Decem…
View article: Atmospheric icing meteorological parameter study using field experiments and simulation
Atmospheric icing meteorological parameter study using field experiments and simulation Open
Atmospheric icing on ground structures is a concern from design, operation, and safety perspectives. Supercooled water droplets size and liquid water content (LWC) are important weather parameters to better understand the ice accretion phy…
View article: Multipoint Raman Spectrometer Based on a Time-Resolved CMOS SPAD Sensor
Multipoint Raman Spectrometer Based on a Time-Resolved CMOS SPAD Sensor Open
The potential of in-line Raman spectrometers for process monitoring applications has been shown for many industrial processes, but in most cases, only one measurement point has been monitored by one spectrometer. In this letter, we describ…
View article: Intercomparison of holographic imaging and single-particle forward light scattering in situ measurements of liquid clouds in changing atmospheric conditions
Intercomparison of holographic imaging and single-particle forward light scattering in situ measurements of liquid clouds in changing atmospheric conditions Open
Upon a new measurement technique, it is possible to sharpen the determination of microphysical properties of cloud droplets using high resolving power imaging. The shape, size, and position of each particle inside a well-defined, three-dim…
View article: Comment on amt-2021-423
Comment on amt-2021-423 Open
Abstract. Upon a new measurement technique, it is possible to sharpen the determination of microphysical properties of cloud droplets using high resolving power imaging. The shape, size, and position of each particle insid…
View article: Comment on amt-2021-423
Comment on amt-2021-423 Open
Abstract. Upon a new measurement technique, it is possible to sharpen the determination of microphysical properties of cloud droplets using high resolving power imaging. The shape, size, and position of each particle insid…
View article: Supplementary material to "Intercomparison of holographic imaging and single-particle forward light scattering in-situ measurements of liquid clouds in changing atmospheric conditions"
Supplementary material to "Intercomparison of holographic imaging and single-particle forward light scattering in-situ measurements of liquid clouds in changing atmospheric conditions" Open
Supplement S1: Cloud boundaries for LWC estimationsCondensation of water vapor introduces strong vertical variations of cloud properties that can be used to define cloud boundaries.However, the location of cloud boundaries depends on the v…
View article: Intercomparison of holographic imaging and single-particle forward light scattering in-situ measurements of liquid clouds in changing atmospheric conditions
Intercomparison of holographic imaging and single-particle forward light scattering in-situ measurements of liquid clouds in changing atmospheric conditions Open
Upon a new measurement technique, it is possible to sharpen the determination of microphysical properties of cloud droplets using high resolving power imaging. The shape, size, and position of each particle inside a well-defined, three-dim…
View article: Compensation of Aerodynamic Sampling Effects of a Cloud Droplet Instrument
Compensation of Aerodynamic Sampling Effects of a Cloud Droplet Instrument Open
Precise sampling is a crucial part of the aerosol measurement processes that ideally requires perfectly isokinetic conditions in which particles in the sampling volume move exactly the same way as they would in an undisturbed flow. Such co…
View article: Validation of Questionnaires in Screening for Restorative Treatment Need among 15-, 21-, and 40-year olds
Validation of Questionnaires in Screening for Restorative Treatment Need among 15-, 21-, and 40-year olds Open
Introduction: This cross-sectional study aims to investigate the association between three age-specific questionnaires in three age groups and restorative dental treatment need. Materials and methods: Three separate questionnaires were des…
View article: Properties and suitability of liquid electrode plasma optical emission spectrometry (LEP-OES) for the determination of potassium, lithium, iron, and zinc in aqueous sample solutions
Properties and suitability of liquid electrode plasma optical emission spectrometry (LEP-OES) for the determination of potassium, lithium, iron, and zinc in aqueous sample solutions Open
The effects of different parameters and the nitric acid concentration on the sensitivity and repeatability of elemental analysis were characterized for liquid electrode plasma optical emission spectrometry (LEP-OES). In addition, internal …
View article: Drug diffusivities in nanofibrillar cellulose hydrogel by combined time-resolved Raman and fluorescence spectroscopy
Drug diffusivities in nanofibrillar cellulose hydrogel by combined time-resolved Raman and fluorescence spectroscopy Open
Hydrogels, natural and synthetic origin, are actively studied for their use for implants and payload carriers. These biomaterials for delivery systems have enormous potential in basic biomedical research, drug development, and long-term de…
View article: Time-Resolved Raman Spectrometer With High Fluorescence Rejection Based on a CMOS SPAD Line Sensor and a 573-nm Pulsed Laser
Time-Resolved Raman Spectrometer With High Fluorescence Rejection Based on a CMOS SPAD Line Sensor and a 573-nm Pulsed Laser Open
A time-resolved Raman spectrometer is demonstrated based on a 256 × 8 single-photon avalanche diodes fabricated in CMOS technology (CMOS SPAD) line sensor and a 573-nm fiber-coupled diamond Raman laser delivering pulses with duration below…
View article: The Effect of Drop Shape, Sensing Volume and Raindrop Size Statistics to the Scattered Field on 300 GHz
The Effect of Drop Shape, Sensing Volume and Raindrop Size Statistics to the Scattered Field on 300 GHz Open
Scattering and attenuation properties of rain using various drop models are calculated using Mie theory, the T-matrix method and numerical technique respectively. Ellipsoidal and oblate drops use the axis ratio of raindrops reported in lit…
View article: Can health kiosks be used to identify oral health care needs? A pilot study
Can health kiosks be used to identify oral health care needs? A pilot study Open
It can be concluded that health kiosks may help to reduce the number of patients waiting for dental treatment; more specifically, the questionnaire with individual feedback may provide a new instrument for providing instructions for homeca…
View article: A rotating holographic imager for stationary cloud droplet and ice crystal measurements
A rotating holographic imager for stationary cloud droplet and ice crystal measurements Open
View article: Predicting scattering properties of fiber suspensions using Mie theory and probabilistic cross-sectional diameter of fibers
Predicting scattering properties of fiber suspensions using Mie theory and probabilistic cross-sectional diameter of fibers Open
View article: Testing of the assisting software for radiologists analysing head CT images: lessons learned
Testing of the assisting software for radiologists analysing head CT images: lessons learned Open
View article: Evaluation of time-gated Raman spectroscopy for the determination of nitric, sulfuric and hydrofluoric acid concentrations in pickle liquor
Evaluation of time-gated Raman spectroscopy for the determination of nitric, sulfuric and hydrofluoric acid concentrations in pickle liquor Open
View article: Comparison of the performance of a microwave based and an NMR based biomaterial moisture measurement instruments
Comparison of the performance of a microwave based and an NMR based biomaterial moisture measurement instruments Open
This article compares the performance of an NMR-based and a microwave based moisture measurement instruments designed for biomaterials. The conventional moisture measurement method, Loss-on-Drying (LoD) serves as a reference measurement fo…
View article: CARDS: the decision support tool for radiologists examining head CT images
CARDS: the decision support tool for radiologists examining head CT images Open
Poster: ECR 2016 / B-0233 / CARDS: the decision support tool for radiologists examining head CT images by: P. N. Martynov , N. Mitropolskii, K. Kukkola, L. Mutanen, J. Reponen, A. Makynen; Oulu/FI
View article: METefnet: developments in metrology for moisture in materials
METefnet: developments in metrology for moisture in materials Open
Bien que les mesures de teneur en eau soient largement utilisées dans l'industrie, les considérations métrologiques quant à cette mesure ne sont pas complètement abouties de sorte à fournir des mesures fiables et traçables au SI.Afin de re…
View article: METefnet: developments in metrology for moisture in materials
METefnet: developments in metrology for moisture in materials Open
Bien que les mesures de teneur en eau soient largement utilisées dans l'industrie, les considérations métrologiques quant à cette mesure ne sont pas complètement abouties de sorte à fournir des mesures fiables et traçables au SI. Afin de r…