Avner Belkin
YOU?
Author Swipe
View article: Comparative Evaluation of Classic Mechanical and Digital Goldmann Applanation Tonometers
Comparative Evaluation of Classic Mechanical and Digital Goldmann Applanation Tonometers Open
Objectives: The objective of this study was to evaluate the agreement and clinical interchangeability of intraocular pressure (IOP) measurements obtained with the mechanical Haag-Streit AT900 Goldmann applanation tonometer (mGAT) and the d…
View article: Surgical Outcomes of Gonioscopy-Assisted Transluminal Trabeculotomy (GATT) in Primary and Secondary Open- and Closed-Angle Glaucoma
Surgical Outcomes of Gonioscopy-Assisted Transluminal Trabeculotomy (GATT) in Primary and Secondary Open- and Closed-Angle Glaucoma Open
Background: Gonioscopy-assisted transluminal trabeculotomy (GATT) is a minimally invasive, ab interno conjunctival-sparing glaucoma surgery aimed at the trabecular meshwork and the inner wall of Schlemm’s canal. The goal of this study is t…
View article: Gonioscopy-assisted transluminal trabeculotomy after failed angle surgery – A case series
Gonioscopy-assisted transluminal trabeculotomy after failed angle surgery – A case series Open
This case series has evaluated the efficacy of Gonioscopy-assisted transluminal trabeculotomy (GATT) in cases where previous angle surgery failed. It included three patients with different forms of open-angle glaucoma. After undergoing GAT…
View article: Safety of One-Piece Hydrophilic Acrylic Intraocular Lenses in the Ciliary Sulcus
Safety of One-Piece Hydrophilic Acrylic Intraocular Lenses in the Ciliary Sulcus Open
Background/Objectives: this study aims to assess the safety of ciliary sulcus-placed hydrophilic acrylic intraocular lenses (IOLs). Methods: In this retrospective cohort study, consecutive patients who underwent phacoemulsification with im…
View article: Gonioscopy-assisted transluminal trabeculotomy (GATT) with scleral or iris fixation for subluxated intraocular lenses and glaucoma
Gonioscopy-assisted transluminal trabeculotomy (GATT) with scleral or iris fixation for subluxated intraocular lenses and glaucoma Open
Introduction: This retrospective chart review aims to report a combined surgical approach of intraocular lens (IOL) fixation and gonioscopy-assisted transluminal trabeculotomy (GATT) for the treatment of subluxated IOLs and glaucoma or ocu…
View article: WITHDRAWN: Comparison of anterior chamber intraocular lens implantation versus four-flanged scleral fixation technique for cases with loss of capsular support during routine cataract surgery
WITHDRAWN: Comparison of anterior chamber intraocular lens implantation versus four-flanged scleral fixation technique for cases with loss of capsular support during routine cataract surgery Open
The full text of this preprint has been withdrawn by the authors in order to comply with an institutional policy on preprints. Therefore, the authors do not wish this work to be cited as a reference.
View article: WITHDRAWN: Comparison of anterior chamber intraocular lens implantation versus four-flanged scleral fixation technique for cases with loss of capsular support during routine cataract surgery
WITHDRAWN: Comparison of anterior chamber intraocular lens implantation versus four-flanged scleral fixation technique for cases with loss of capsular support during routine cataract surgery Open
Purpose: To compare the outcomes of anterior chamber intraocular lens (ACIOL) implantation vs the four-flanged scleral fixation technique in eyes with loss of capsular support during routine cataract surgery. Design: A retrospective cohort…
View article: THE EFFECT OF INTERNAL LIMITING MEMBRANE PEELING ON THE INNER RETINAL LAYERS IN PATIENTS WITHOUT MACULAR PATHOLOGIC CONDITION
THE EFFECT OF INTERNAL LIMITING MEMBRANE PEELING ON THE INNER RETINAL LAYERS IN PATIENTS WITHOUT MACULAR PATHOLOGIC CONDITION Open
Background: To examine the effect of internal limiting membrane peeling on the inner retinal layers in patients without macular pathological condition. Methods: A prospective nonrandomized trial of patients undergoing pars plana vitrectomy…
View article: Gonioscopy-assisted transluminal trabeculotomy in patients with advanced glaucoma
Gonioscopy-assisted transluminal trabeculotomy in patients with advanced glaucoma Open
Purpose: To evaluate the efficacy and safety of gonioscopy-assisted transluminal trabeculotomy (GATT) in patients with advanced glaucoma. Methods: Records of 46 patients with advanced glaucoma were reviewed retrospectively in this single-c…
View article: Surgical outcomes of Gonioscopy-assisted Transluminal Trabeculotomy (GATT) in Primary and Secondary Open and Closed Angle Glaucoma
Surgical outcomes of Gonioscopy-assisted Transluminal Trabeculotomy (GATT) in Primary and Secondary Open and Closed Angle Glaucoma Open
Background Gonioscopy assisted transluminal trabeculotomy (GATT) is a minimally invasive, ab interno conjunctival sparing glaucoma surgery aimed at the trabecular meshwork and the inner wall of Schlemm’s canal. The goal of this study is to…
View article: Segmental Suture Gonioscopy-Assisted Transluminal Trabeculotomy: Comparison of Superior Versus Inferior Hemisphere Outcomes
Segmental Suture Gonioscopy-Assisted Transluminal Trabeculotomy: Comparison of Superior Versus Inferior Hemisphere Outcomes Open
Précis: Analysis of efficacy, safety, and risk factors for failure of superior versus inferior 180-degree segmental gonioscopy-assisted transluminal trabeculectomy showed no significant difference between approaches, with novel risk factor…
View article: The effect of hypotensive drugs on intraocular lenses clarity
The effect of hypotensive drugs on intraocular lenses clarity Open
View article: Gonioscopy-assisted Transluminal Trabeculotomy (GATT) with Scleral or Iris Fixation for Subluxated Intraocular Lenses and Glaucoma
Gonioscopy-assisted Transluminal Trabeculotomy (GATT) with Scleral or Iris Fixation for Subluxated Intraocular Lenses and Glaucoma Open
Purpose – To report on a combined surgical approach of IOL fixation and GATT for the treatment of subluxated IOLs and glaucoma. Methods – In this retrospective cohort, Charts of patients who underwent IOL-fixation combined with GATT betwee…
View article: Trans-optic Suture Fixation of Subluxated Intraocular Lenses
Trans-optic Suture Fixation of Subluxated Intraocular Lenses Open
PurposeTo report a technique for fixating posterior chamber intraocular lenses (PCIOLs) to the sclera by passing sutures through the lens materialMethodsCases in which PCIOLs were fixated to the sclera using trans-optic sutures were includ…
View article: The Effect of Hypotensive drugs on Intraocular Lens Clarity
The Effect of Hypotensive drugs on Intraocular Lens Clarity Open
View article: Ophthalmic emergency-room visits during the Covid-19 pandemic – a comparative study
Ophthalmic emergency-room visits during the Covid-19 pandemic – a comparative study Open
View article: Safety of 3 Tesla Magnetic Resonance Imaging on iStent Implants: An Ex-Vivo Study
Safety of 3 Tesla Magnetic Resonance Imaging on iStent Implants: An Ex-Vivo Study Open
Précis: Our study shows that iStent implant does not cause significant image artifacts, heating, or displacement during magnetic resonance imaging (MRI) scan. This device can be safely used in patients undergoing MRI scans using 3 Tesla (3…
View article: Ophthalmic Emergency-Room Visits During The COVID-19 Pandemic – A Comparative Study
Ophthalmic Emergency-Room Visits During The COVID-19 Pandemic – A Comparative Study Open
Purpose: To compare ophthalmic emergency room (OER) visits during the COVID-19 pandemic to those during a control period. Methods: We compared all visits to the OER from March 15 th to April 15 th , 2020, during the Covid-19 pandemic and g…
View article: The effect of trabeculectomy and glaucoma drainage device implantation on postural intraocular pressure changes in glaucomatous eyes
The effect of trabeculectomy and glaucoma drainage device implantation on postural intraocular pressure changes in glaucomatous eyes Open
Purpose To investigate the effect of trabeculectomy and glaucoma drainage device implantation on posture related intraocular pressure (IOP) changes in glaucomatous eyes. Methods Eyes in this prospective study were divided into three groups…
View article: Eye patching after cataract surgery is associated with an increased risk of short‐term corneal oedema
Eye patching after cataract surgery is associated with an increased risk of short‐term corneal oedema Open
Purpose To evaluate the effect of postoperative eye patching after routine cataract surgery on corneal oedema and visual acuity on the first postoperative day. Setting One public healthcare centre. Design and methods This randomized contro…
View article: Explantation of BrightOcular cosmetic iris implant and goniosynechialysis: A case report
Explantation of BrightOcular cosmetic iris implant and goniosynechialysis: A case report Open
A 48-year-old lady presented with bilateral symptomatic uveitis. She had bilateral cosmetic iris implantation 4 years ago. She underwent bilateral cosmetic iris explantation and goniosynechialysis to open up areas of angle compromise. This…
View article: EFFECT OF POSTURAL CHANGES ON THE TRANS LAMINA CRIBROSA PRESSURE DIFFERENCE – A PILOT STUDY
EFFECT OF POSTURAL CHANGES ON THE TRANS LAMINA CRIBROSA PRESSURE DIFFERENCE – A PILOT STUDY Open
View article: Wound temperature profiles of coaxial mini‐incision <i>versus</i> sleeveless microincision phacoemulsification
Wound temperature profiles of coaxial mini‐incision <i>versus</i> sleeveless microincision phacoemulsification Open
Background Temperature profiles at the corneal wound of coaxial mini‐incision (2.4 mm) cataract surgery and sleeveless microincision (1.1 mm) cataract surgery were compared. Design Prospective, controlled, paired‐eye clinical trial conduct…