Bradley N. Bohnstedt
YOU?
Author Swipe
View article: Comaneci-assisted embolization of wide-necked aneurysms: results from the SUCCESS postmarket US study
Comaneci-assisted embolization of wide-necked aneurysms: results from the SUCCESS postmarket US study Open
Background Wide-necked intracranial aneurysms present unique challenges for endovascular treatment. The Comaneci device is a novel temporary bridging device designed to assist coil embolization without parent vessel occlusion. Methods The …
View article: Basilar Artery Occlusion Stroke Managed With Tenecteplase Versus Alteplase Before Endovascular Treatment (BAO‐TNK)
Basilar Artery Occlusion Stroke Managed With Tenecteplase Versus Alteplase Before Endovascular Treatment (BAO‐TNK) Open
Objective To compare the effectiveness and safety of tenecteplase (TNK) versus alteplase (TPA) in patients with basilar artery occlusion prior to endovascular treatment (EVT). Methods In this retrospective multicenter study (BAO‐TNK), we a…
View article: Intracranial aneurysm embolization using Penumbra fill and finish coils: 1-year results of a prospective, real-world, multicenter SURF study
Intracranial aneurysm embolization using Penumbra fill and finish coils: 1-year results of a prospective, real-world, multicenter SURF study Open
Background SURF was a prospective, multicenter, single-arm, observational study with core lab adjudication of radiographic data, assessing embolization of intracranial aneurysms (IAs) using WAVE Extra Soft Coils as part of SMART Coil Syste…
View article: Towards the Intravascular Delivery of 3D-printed Leached SMP for Endovascular Treatment of Intracranial Aneurysm
Towards the Intravascular Delivery of 3D-printed Leached SMP for Endovascular Treatment of Intracranial Aneurysm Open
Purpose Intracranial aneurysms (ICAs) pose a serious clinical risk due to their potential for rupture, leading to subarachnoid hemorrhage, high morbidity, and mortality. This study aims to develop a proof-of-concept device for the targeted…
View article: Three-Dimensional Modeling of Anterior Communicating Artery Aneurysm for Surgical Simulation
Three-Dimensional Modeling of Anterior Communicating Artery Aneurysm for Surgical Simulation Open
Background: A ruptured cerebral aneurysm is a common cause of life-threatening subarachnoid hemorrhage and can be treated using open surgical clipping or endovascular coiling and stenting. Most aneurysms arise on typical sites on the circl…
View article: Kyphoplasty as a Treatment Option for Traumatic Burst Fractures: A Case Series Evaluating Patient Outcomes and Functional Benefits
Kyphoplasty as a Treatment Option for Traumatic Burst Fractures: A Case Series Evaluating Patient Outcomes and Functional Benefits Open
Background/Objectives: Kyphoplasty and vertebroplasty are minimally invasive approaches for spinal fractures aiming to reduce pain, increase mobilization, and prevent further vertebral height loss. Their efficacy in treating burst fracture…
View article: Outcomes of Grade 3 Carotid Dissections: A 7-Year Retrospective Analysis of Stroke, Stenosis, and Pseudoaneurysm Progression
Outcomes of Grade 3 Carotid Dissections: A 7-Year Retrospective Analysis of Stroke, Stenosis, and Pseudoaneurysm Progression Open
Grade 3 carotid dissections have variable outcomes, with most improving or resolving. However, the persistent risk of stroke and pseudoaneurysm progression emphasizes the need for vigilant long-term monitoring and reconsideration of optima…
View article: Management of Type III Occipital Condyle Fractures
Management of Type III Occipital Condyle Fractures Open
Background/Objectives: Occipital condyle fractures (OCFs) can be seen in around 4–19% of patients who suffer from cervical spine trauma. Anderson and Montesano system type III OCFs, which are avulsion fractures, are potentially unstable an…
View article: Recent trends of treatment strategies and outcomes of basal ganglia hemorrhages at a single institution
Recent trends of treatment strategies and outcomes of basal ganglia hemorrhages at a single institution Open
Objective: The Early Minimally Invasive Removal of Intracerebral Hemorrhage (ENRICH) Trial was designed to evaluate the minimally invasive trans-sulcal parafascicular surgery (MIPS) approach, a technique advertised for safe access to deep …
View article: Systematic Review and Meta‐Analysis of Endovascular Therapy Effectiveness for Unruptured Saccular Intracranial Aneurysms
Systematic Review and Meta‐Analysis of Endovascular Therapy Effectiveness for Unruptured Saccular Intracranial Aneurysms Open
Background Currently, endovascular treatment of intracranial aneurysms is limited by low complete occlusion rates. The advent of novel endovascular technology has expanded the applicability of endovascular therapies; however, the superiori…
View article: Toward the Development of a Shape Memory Polymer for Individualized Endovascular Therapy of Intracranial Aneurysms Using a 3D‐Printing/Leaching Method
Toward the Development of a Shape Memory Polymer for Individualized Endovascular Therapy of Intracranial Aneurysms Using a 3D‐Printing/Leaching Method Open
Endovascular treatment of intracranial aneurysms (ICA) aims to occlude the aneurysm space to prevent ICA growth/rupture. Modern endovascular techniques are still limited by relatively low complete occlusion rates, frequently leading to ane…
View article: Systematic Review and Meta-Analysis of Endovascular Therapy Effectiveness for Unruptured Saccular Intracranial Aneurysms
Systematic Review and Meta-Analysis of Endovascular Therapy Effectiveness for Unruptured Saccular Intracranial Aneurysms Open
Background Currently, endovascular treatment of intracranial aneurysms (ICAs) is limited by low complete occlusion rates. The advent of novel endovascular technology has expanded the applicability of endovascular therapy; however, the supe…
View article: Safety and Efficacy of MCA‐M2 Thrombectomy in Delayed Time Window: A Propensity Score Analysis From the STAR Registry
Safety and Efficacy of MCA‐M2 Thrombectomy in Delayed Time Window: A Propensity Score Analysis From the STAR Registry Open
Background Mechanical thrombectomy of middle cerebral artery M2 segment occlusion of the middle cerebral artery has reported safety and efficacy in recent post‐hoc and observational studies. However, there is no known benefit of mechanical…
View article: Abstract Number ‐ 3: Large and Giant Aneurysms Outcome in the Multicenter Prospective Core Lab Adjudicated SMART Coils Registry
Abstract Number ‐ 3: Large and Giant Aneurysms Outcome in the Multicenter Prospective Core Lab Adjudicated SMART Coils Registry Open
Introduction Endovascular coiling for intracerebral aneurysms has been evolving. Yet, large, and giant aneurysms (LAGA) remain a significant challenge for treatment and carry a high rate of morbidity and mortality. Previous studies have de…
View article: Correlation of Outcomes Following Mechanical Thrombectomy in Covid-19 Patients with Ischemic Stroke
Correlation of Outcomes Following Mechanical Thrombectomy in Covid-19 Patients with Ischemic Stroke Open
Background/Objective: SARS-CoV-2 is a respiratory virus most well-known for causing acute respiratory failure. COVID-19 can cause a variety of conditions with poor prognoses, such as cerebrovascular accidents (CVA). COVID-19 is believed to…
View article: Shape Memory Polymer-Based Endovascular Devices: Design Criteria and Future Perspective
Shape Memory Polymer-Based Endovascular Devices: Design Criteria and Future Perspective Open
Devices for the endovascular embolization of intracranial aneurysms (ICAs) face limitations related to suboptimal rates of lasting complete occlusion. Incomplete occlusion frequently leads to residual flow within the aneurysm sac, which su…
View article: Endovascular treatment of penetrating nail gun injury of the cervical spine and vertebral artery: a case report
Endovascular treatment of penetrating nail gun injury of the cervical spine and vertebral artery: a case report Open
In this report, we present a case of high cervical penetrating trauma with vertebral artery injury and outline preprocedural, procedural, and postprocedural considerations with recommendations for the treatment of similar injuries. Managem…
View article: Abstract 1122‐000087: Long‐Term Outcomes of Anterior Communicating Artery Aneurysm Treated with Coiling: Subset Analysis of SMART Registry
Abstract 1122‐000087: Long‐Term Outcomes of Anterior Communicating Artery Aneurysm Treated with Coiling: Subset Analysis of SMART Registry Open
This meeting abstract was removed due to the OA licensing requirements of this journal. The full abstract is listed here : https://www.svin.org/files/SVIN_2021_Abstracts_for_Web.pdf
View article: Abstract 1122‐000113: Periprocedural Safety of Intracranial Aneurysm Embolization with Extra Soft Coils: Interim Analysis of SURF Study
Abstract 1122‐000113: Periprocedural Safety of Intracranial Aneurysm Embolization with Extra Soft Coils: Interim Analysis of SURF Study Open
This meeting abstract was removed due to the OA licensing requirements of this journal. The full abstract is listed here : https://www.svin.org/files/SVIN_2021_Abstracts_for_Web.pdf
View article: A protocol for the reduction of applied torque on parent vessel during elastase-induced aneurysm formation using rabbit animal models
A protocol for the reduction of applied torque on parent vessel during elastase-induced aneurysm formation using rabbit animal models Open
Endovascular therapies for intracranial aneurysms requires animal models for testing the safety and effectiveness prior to translation to the clinic. Rabbits combined with the elastase and right common carotid artery (RCCA) ligation method…
View article: EP20 Safety and performance of the penumbra SMART COIL system for patients with posterior circulation aneurysm
EP20 Safety and performance of the penumbra SMART COIL system for patients with posterior circulation aneurysm Open
Introduction Treatment of posterior circulation aneurysm has high rates of morbidity and mortality. Aim of the Study Evaluate the safety and performance of the SMART COIL System through 1-year follow-up in posterior circulation aneurysm pa…
View article: P-048 Safety and performance of the penumbra smart coil system for patients with posterior aneurysms
P-048 Safety and performance of the penumbra smart coil system for patients with posterior aneurysms Open
Introduction/Purpose The purpose of this analysis was to evaluate the safety and performance of the SMART COIL System through one year of follow-up in patients with posterior aneurysms enrolled in the SMART registry. Materials and Methods …
View article: The SMART Registry: Long-Term Results on the Utility of the Penumbra SMART COIL System for Treatment of Intracranial Aneurysms and Other Malformations
The SMART Registry: Long-Term Results on the Utility of the Penumbra SMART COIL System for Treatment of Intracranial Aneurysms and Other Malformations Open
Introduction: Penumbra SMART COIL® (SMART) System is a novel generation embolic coil with varying stiffness. The study purpose was to report real-world usage of the SMART System in patients with intracranial aneurysms (ICA) and non-aneurys…
View article: Periprocedural safety of saccular aneurysm embolization with the Penumbra SMART Coil System: a SMART registry subset analysis
Periprocedural safety of saccular aneurysm embolization with the Penumbra SMART Coil System: a SMART registry subset analysis Open
Background Using data from the SMART registry, we report on periprocedural safety of the Penumbra SMART Coil System for endovascular coil embolization of saccular intracranial aneurysms. Methods The SMART registry was a prospective, multi-…