Benjamin Schaaf
YOU?
Author Swipe
View article: Full-Locked Coil Ropes with HDPE Sheath: Studies of Mechanical Behavior of HDPE Under Accelerated Aging
Full-Locked Coil Ropes with HDPE Sheath: Studies of Mechanical Behavior of HDPE Under Accelerated Aging Open
In accordance with German guideline ZTV-ING Part 4, full-locked coil ropes are provided with a three-layer corrosion protection coating based on epoxy resin and polyurethane, which must be renewed regularly. An alternative method is to use…
View article: Time-dependent design of hyperelastic bonded joints in structural glass
Time-dependent design of hyperelastic bonded joints in structural glass Open
For glass constructions with a high degree of transparency, facade systems with structural sealant glazing are increasingly being used. However, the use of bonded joints is also suitable for many other applications in glass construction. E…
View article: Application of a mobile measuring device for the planar evaluation of the current in-situ stress condition in glass
Application of a mobile measuring device for the planar evaluation of the current in-situ stress condition in glass Open
The load-bearing capacity of glass as a structural material as well as sustainability and resistance of a built-in glass against appearing loads and forces is assuming an ever-greater importance. Next to analytical and numerical calculatio…
View article: Material modeling of hyperelastic silicone adhesives considering stiffness reduction
Material modeling of hyperelastic silicone adhesives considering stiffness reduction Open
Predicting the hyperelastic behavior and the stiffness reduction of adhesive is essential for the economical dimensioning of load‐bearing bonds in the field of glass façade construction. The typical hyperelastic behavior can be modeled by …
View article: Development of a Mobile Device for the Evaluation of the Current in Situ Stress Condition in Glass
Development of a Mobile Device for the Evaluation of the Current in Situ Stress Condition in Glass Open
In present-day practice, monitoring the installation process and the utilisation of glass and hybrid components, e.g. glass/steel or glass/plastic, has become increasingly important. To date, the quality control options for built-in glass …
View article: Hybrid Steel-Glass Cell: Cold-twisting and Buckling Phenomena
Hybrid Steel-Glass Cell: Cold-twisting and Buckling Phenomena Open
The European RFCS project “S+G” has developed innovative steel-glass composite systems for high-performance building skins, meeting requirements of structural and energetic efficiency, as well as aesthetical value and versatility of applic…