Brian A. Francis
YOU?
Author Swipe
View article: Bio-Interventional Uveoscleral Outflow Enhancement for Intraocular Pressure Reduction in Open-Angle Glaucoma: One-Year Results of a Multicenter Prospective Real-world Evidence Study
Bio-Interventional Uveoscleral Outflow Enhancement for Intraocular Pressure Reduction in Open-Angle Glaucoma: One-Year Results of a Multicenter Prospective Real-world Evidence Study Open
Background: Open-angle glaucoma (OAG) is a chronic optic neuropathy and major cause of blindness. Current treatments lower intraocular pressure (IOP) by enhancing aqueous outflow via the trabecular or uveoscleral pathways. This study repor…
View article: One-Year Real-World Outcomes of Ab-Externo Gel Stent Placement From the EXPAND Study
One-Year Real-World Outcomes of Ab-Externo Gel Stent Placement From the EXPAND Study Open
Précis: In the real-world, retrospective, EXPAND study of consecutive adults with glaucoma, ab-externo gel stent implantation effectively lowered intraocular pressure (34%) and the medication burden (61%), with transient/self-resolving hyp…
View article: Ab-Externo MicroShunt versus Trabeculectomy in Primary Open-Angle Glaucoma
Ab-Externo MicroShunt versus Trabeculectomy in Primary Open-Angle Glaucoma Open
View article: Evidence-Based Consensus Guidelines Series for MicroPulse Transscleral Laser Therapy - Surgical Technique, Post-Operative Care, Expected Outcomes and Retreatment/Enhancements
Evidence-Based Consensus Guidelines Series for MicroPulse Transscleral Laser Therapy - Surgical Technique, Post-Operative Care, Expected Outcomes and Retreatment/Enhancements Open
Used within appropriate treatment parameters, with proper technique and patient selection, MicroPulse TLT is a safe and effective treatment for many types and severities of glaucoma. MicroPulse TLT represents a useful addition to the glauc…
View article: Evidence-Based Consensus Guidelines Series for MicroPulse Transscleral Laser Therapy: Dosimetry and Patient Selection
Evidence-Based Consensus Guidelines Series for MicroPulse Transscleral Laser Therapy: Dosimetry and Patient Selection Open
Micropulse TLT is a useful addition to the glaucoma armamentarium. When used with proper surgical technique at energy settings within the boundaries described in this manuscript, MicroPulse TLT is a safe and effective treatment for many ty…
View article: Harmonizing OCT and VF parameters in the assessment of glaucoma progression speed
Harmonizing OCT and VF parameters in the assessment of glaucoma progression speed Open
View article: Segmental differences found in aqueous angiographic-determined high - and low-flow regions of human trabecular meshwork
Segmental differences found in aqueous angiographic-determined high - and low-flow regions of human trabecular meshwork Open
View article: American Glaucoma Society Position Paper: Microinvasive Glaucoma Surgery
American Glaucoma Society Position Paper: Microinvasive Glaucoma Surgery Open
View article: Estimating Visual Field Mean Deviation using Optical Coherence Tomographic Nerve Fiber Layer Measurements in Glaucoma Patients
Estimating Visual Field Mean Deviation using Optical Coherence Tomographic Nerve Fiber Layer Measurements in Glaucoma Patients Open
To construct an optical coherence tomography (OCT) nerve fiber layer (NFL) parameter that has maximal correlation and agreement with visual field (VF) mean deviation (MD). The NFL_MD parameter in dB scale was calculated from the peripapill…
View article: Correlation between Anterior Segment OCT and Novel 360o Angle Imaging
Correlation between Anterior Segment OCT and Novel 360o Angle Imaging Open
View article: Predictive Factors for the Rate of Visual Field Progression in the Advanced Imaging for Glaucoma Study
Predictive Factors for the Rate of Visual Field Progression in the Advanced Imaging for Glaucoma Study Open
View article: Comparison of Glaucoma Progression Detection by Optical Coherence Tomography and Visual Field
Comparison of Glaucoma Progression Detection by Optical Coherence Tomography and Visual Field Open
View article: Efficacy and safety of MicroPulse transscleral diode laser cyclophotocoagulation in the treatment of refractory glaucoma.
Efficacy and safety of MicroPulse transscleral diode laser cyclophotocoagulation in the treatment of refractory glaucoma. Open
View article: Comparison of Glaucoma Progression Detection by Optical Coherence Tomography and Visual Field
Comparison of Glaucoma Progression Detection by Optical Coherence Tomography and Visual Field Open
View article: Effects of diurnal, lighting, and angle-of-incidence variation on anterior segment optical coherence tomography (AS-OCT) angle metrics
Effects of diurnal, lighting, and angle-of-incidence variation on anterior segment optical coherence tomography (AS-OCT) angle metrics Open
View article: Retinal vessel density from optical coherence tomography angiography to differentiate early glaucoma, pre-perimetric glaucoma and normal eyes
Retinal vessel density from optical coherence tomography angiography to differentiate early glaucoma, pre-perimetric glaucoma and normal eyes Open
Eyes with mild POAG could be differentiated from pre-perimetric glaucoma eyes, which also could be differentiated from normal eyes using OCTA-derived retinal vessel density measurements.
View article: Vision Loss and Recovery after Baerveldt Aqueous Tube Shunt Implantation
Vision Loss and Recovery after Baerveldt Aqueous Tube Shunt Implantation Open
This study aims to determine the course of vision loss after Baerveldt aqueous tube shunt placement and identify risk factors associated with unexplained severe long-term vision loss, or snuff-out. We retrospectively reviewed 247 eyes of 2…
View article: Additional file 1: of Effects of diurnal, lighting, and angle-of-incidence variation on anterior segment optical coherence tomography (AS-OCT) angle metrics
Additional file 1: of Effects of diurnal, lighting, and angle-of-incidence variation on anterior segment optical coherence tomography (AS-OCT) angle metrics Open
Effects of Diurnal, Lighting, and Angle-of-Incidence Variation on Anterior Segment Optical Coherence Tomography Angle Metrics. Description of the data: Angle metrics were recorded from the scans of the morning and the afternoon with differ…
View article: Supplementary Material for: Refining Prognosis for Intracerebral Hemorrhage by Early Reassessment
Supplementary Material for: Refining Prognosis for Intracerebral Hemorrhage by Early Reassessment Open
Background: Prognostic assessments, which are crucial for decision-making in critical illnesses, have shown unsatisfactory reliability. We compared the accuracy of a widely used prognostic score against a model derived from c…
View article: Short-Term Clinical Results of Ab Interno Trabeculotomy Using the Trabectome with or without Cataract Surgery for Open-Angle Glaucoma Patients of High Intraocular Pressure
Short-Term Clinical Results of Ab Interno Trabeculotomy Using the Trabectome with or without Cataract Surgery for Open-Angle Glaucoma Patients of High Intraocular Pressure Open
Purpose . To assess the safety and efficacy of Trabectome procedure in patients with preoperative intraocular pressure (IOP) of 30 mmHg or higher. Methods . All patients who had underwent Trabectome stand-alone or Trabectome combined with …
View article: Supplementary Material for: Refining Prognosis for Intracerebral Hemorrhage by Early Reassessment
Supplementary Material for: Refining Prognosis for Intracerebral Hemorrhage by Early Reassessment Open
Background: Prognostic assessments, which are crucial for decision-making in critical illnesses, have shown unsatisfactory reliability. We compared the accuracy of a widely used prognostic score against a model derived from c…
View article: Minimally Invasive Glaucoma Surgery
Minimally Invasive Glaucoma Surgery Open
His areas of interest are the surgical management of glaucoma, especially surgical devices and secondary glaucomas and specifically the management of glaucoma in uveitis.He has been an investigator in the TVT study and PTVT study, co-chair…
View article: Aqueous Angiography with Fluorescein and Indocyanine Green in Bovine Eyes
Aqueous Angiography with Fluorescein and Indocyanine Green in Bovine Eyes Open
Further characterization of segmental AHO with aqueous angiography may allow for intelligent placement of trabecular bypass minimally invasive glaucoma surgeries for improved surgical results.
View article: Baseline Fourier-Domain Optical Coherence Tomography Structural Risk Factors for Visual Field Progression in the Advanced Imaging for Glaucoma Study
Baseline Fourier-Domain Optical Coherence Tomography Structural Risk Factors for Visual Field Progression in the Advanced Imaging for Glaucoma Study Open
View article: Aqueous Angiography–Mediated Guidance of Trabecular Bypass Improves Angiographic Outflow in Human Enucleated Eyes
Aqueous Angiography–Mediated Guidance of Trabecular Bypass Improves Angiographic Outflow in Human Enucleated Eyes Open
Using sequential aqueous angiography in an enucleated human eye model system, regions initially without angiographic flow or signal could be recruited for AHO using a trabecular bypass stent.
View article: Endoscopic cyclophotocoagulation <i>versus</i> second glaucoma drainage device after prior aqueous tube shunt surgery
Endoscopic cyclophotocoagulation <i>versus</i> second glaucoma drainage device after prior aqueous tube shunt surgery Open
Background To evaluate the efficacy in controlling intraocular pressure (IOP) with endoscopic cyclophotocoagulation (ECP) versus implantation of a second glaucoma drainage device (GDD‐2) in the treatment of uncontrolled glaucoma with a pri…
View article: Repeatability of selective laser trabeculoplasty for open-angle glaucoma
Repeatability of selective laser trabeculoplasty for open-angle glaucoma Open
View article: Steroid‐induced glaucoma treated with trabecular ablation in a matched comparison with primary open‐angle glaucoma
Steroid‐induced glaucoma treated with trabecular ablation in a matched comparison with primary open‐angle glaucoma Open
Background To evaluate the outcomes of trabectome‐mediated ab interno trabeculectomy in patients with steroid‐induced glaucoma (SIG). Design A retrospective, observational cohort study performed in the Department of Ophthalmology, Universi…
View article: Utility of anterior segment swept-source optical coherence tomography for imaging eyes with antecedent ocular trauma
Utility of anterior segment swept-source optical coherence tomography for imaging eyes with antecedent ocular trauma Open
The anterior segment SS-OCT is a useful device allowing non-invasive, non-contact, real-time, cross-sectional anterior segment images of eyes with previous ocular trauma.
View article: Clinical results of ab interno trabeculotomy using the Trabectome in patients with pigmentary glaucoma compared to primary open angle glaucoma
Clinical results of ab interno trabeculotomy using the Trabectome in patients with pigmentary glaucoma compared to primary open angle glaucoma Open
Background To evaluate outcomes of Trabectome on pigmentary glaucoma (PG) patients compared to matched controls with primary open angle glaucoma (POAG). Design Prospective comparison study Participants A total of 101 POAG cases were matche…