Caleb Behrend
YOU?
Author Swipe
View article: Proof of concept measurement of ovine intertrochanteric fracture stability with an X-ray visualized implantable screw bending sensor
Proof of concept measurement of ovine intertrochanteric fracture stability with an X-ray visualized implantable screw bending sensor Open
View article: Synovial Fluid pH Sensor for Early Detection of Prosthetic Hip Infections
Synovial Fluid pH Sensor for Early Detection of Prosthetic Hip Infections Open
An implantable sensor developed to measure synovial fluid pH for noninvasive early detection and monitoring of hip infections using standard‐of‐care plain radiography is described. The sensor is made of a pH responsive polyacrylic acid‐bas…
View article: Measuring Intertrochanteric Fracture Stability with a Novel Strain-Sensing Sliding Hip Screw
Measuring Intertrochanteric Fracture Stability with a Novel Strain-Sensing Sliding Hip Screw Open
Background Bone healing after internal fixation of intertrochanteric hip fractures is difficult to monitor with radiography, particularly with internal fixation implants such as the sliding hip screw (SHS). In this study, we evaluate a rob…
View article: Measuring Orthopedic Plate Strain to Track Bone Healing Using a Fluidic Sensor Read via Plain Radiography
Measuring Orthopedic Plate Strain to Track Bone Healing Using a Fluidic Sensor Read via Plain Radiography Open
We describe a fluidic X-ray visualized strain indicator under applied load (X-VISUAL) to quantify orthopedic plate strain and inform rehabilitative care. This sensor uses a liquid-level gauge with hydro-mechanical amplification and is visu…
View article: Noninvasively Imaging pH at the Surface of Implanted Orthopedic Devices with X-ray Excited Luminescence Chemical Imaging
Noninvasively Imaging pH at the Surface of Implanted Orthopedic Devices with X-ray Excited Luminescence Chemical Imaging Open
Implanted medical device-associated infections are a leading cause of fixation failure, and early diagnosis is the key to successful treatment. During infection, acidosis near the implant plays a role in antibiotic resistance and low pH is…
View article: An implanted pH sensor read using radiography
An implanted pH sensor read using radiography Open
The constructed biosensor enhances the capability of traditional plain film radiography, enabling the noninvasive measurement of postoperative infection indicating chemical concentration such as pH on the implant surfaces.
View article: Symptomatic sacrococcygeal joint dislocation treated using closed manual reduction: A case report with 36-month follow-up and review of literature
Symptomatic sacrococcygeal joint dislocation treated using closed manual reduction: A case report with 36-month follow-up and review of literature Open
View article: C1-2 Fixation Approach for Patients With Vascular Irregularities: A Case Report
C1-2 Fixation Approach for Patients With Vascular Irregularities: A Case Report Open
In posterior spinal fusion (PSF), the vertebral artery is most vulnerable to injury at C1-2. C2 pedicle screws are often placed into the dorsomedial isthmus of C2. Alternative techniques include C2 laminar screws and wiring techniques. A 6…
View article: Implanted chemical sensors for functional radiography
Implanted chemical sensors for functional radiography Open
A biomedical sensor is designed to noninvasively measure local pH changes on the surface of implanted devices for detecting and monitoring implant-associated infection using plain radiography. The sensor comprises a radiopaque pin embedded…
View article: Incidence, Positional Distribution, Severity, and Time Missed in Medial Collateral Ligament Injuries of the Knee in NCAA Division I Football Athletes
Incidence, Positional Distribution, Severity, and Time Missed in Medial Collateral Ligament Injuries of the Knee in NCAA Division I Football Athletes Open
Descriptive Epidemiology Study.
View article: Anterior Cervical Discectomy With Fusion Using a Local Source for Cancellous Autograft: A Biomechanical Analysis of Vertebral Body Stability in an Osteopenic Bone Model
Anterior Cervical Discectomy With Fusion Using a Local Source for Cancellous Autograft: A Biomechanical Analysis of Vertebral Body Stability in an Osteopenic Bone Model Open
Background: Anterior cervical discectomy with fusion is an effective treatment for patients having cervical radiculopathy and myelopathy. To reduce morbidity associated with autograft taken from the iliac crest without sacrificing high fus…
View article: Implantable strain sensor to monitor fracture healing with standard radiography
Implantable strain sensor to monitor fracture healing with standard radiography Open
View article: X-ray excited luminescent chemical imaging (XELCI) for non-invasive imaging of implant infections
X-ray excited luminescent chemical imaging (XELCI) for non-invasive imaging of implant infections Open
X-ray excited luminescent chemical imaging (XELCI) uses a combination of X-ray excitation to provide high resolution and optical detection to provide chemical sensing. A key application is to detect and study implant-associated infection. …
View article: Implanted chemical sensors for functional radiography
Implanted chemical sensors for functional radiography Open
A biomedical sensor is designed to noninvasively measure local pH changes on the surface of implanted devices for detecting and monitoring implant-associated infection using plain radiography. The sensor comprises a radiopaque pin embedded…
View article: Indications for Direct Laryngoscopic Examination of Vocal Cord Function Prior to Anterior Cervical Surgery
Indications for Direct Laryngoscopic Examination of Vocal Cord Function Prior to Anterior Cervical Surgery Open
Recurrent laryngeal nerve palsy (RLNP) is among the most common complications in both thyroid surgeries and anterior approaches to the cervical spine, having both a diverse etiology and presentation. Most bilateral paresis, with subsequent…
View article: A smart polymer hydrogel as a chemical sensor on biomedical implant
A smart polymer hydrogel as a chemical sensor on biomedical implant Open
Orthopedic implants are manufactured to support on healing fractured bones. In United States, over 2 million fracture fixation devices, including intra-medullary nails, external fixation pins, plates, and screws, and over 600 thousands joi…
View article: Allogeneic and Autogenous Bone Grafts Are Affected by Historical Donor Environmental Exposure
Allogeneic and Autogenous Bone Grafts Are Affected by Historical Donor Environmental Exposure Open
Comparable levels of lead exposure have been associated with toxic effects on skeletal tissue. Further study of bone graft used in fusion procedures and other procedures is necessary to define the magnitude of osteotoxic effects in the set…
View article: Financial Implications of Hospital Readmission After Hip Fracture
Financial Implications of Hospital Readmission After Hip Fracture Open
Introduction: Hip fracture is the leading orthopedic discharge diagnosis associated with 30-day readmission in terms of numbers. Because readmission to the hospital following a hip fracture is so common, it adds considerably to the costs o…