Clément Bars
YOU?
Author Swipe
View article: Targetable atrial tachycardias after artificial intelligence–guided ablation of persistent atrial fibrillation
Targetable atrial tachycardias after artificial intelligence–guided ablation of persistent atrial fibrillation Open
View article: ID: 4348732 AI-BASED FRAMEWORK FOR EXPERT-LEVEL DIAGNOSIS OF PERITRICUSPID FLUTTER
ID: 4348732 AI-BASED FRAMEWORK FOR EXPERT-LEVEL DIAGNOSIS OF PERITRICUSPID FLUTTER Open
View article: The use of a contact force–sensing very-high-power short-duration radiofrequency catheter leads to significant efficiency improvement for dispersion-based ablation of persistent atrial fibrillation
The use of a contact force–sensing very-high-power short-duration radiofrequency catheter leads to significant efficiency improvement for dispersion-based ablation of persistent atrial fibrillation Open
View article: Defibrillation Testing During Implantation of Subcutaneous Implantable Cardioverter Defibrillators
Defibrillation Testing During Implantation of Subcutaneous Implantable Cardioverter Defibrillators Open
View article: Atrial contraction recovery in persistent atrial fibrillation patients after a patient-tailored ablation using artificial intelligence-guided spatio-temporal dispersion approach
Atrial contraction recovery in persistent atrial fibrillation patients after a patient-tailored ablation using artificial intelligence-guided spatio-temporal dispersion approach Open
Background/Introduction Recently, the TAILORED-AF randomized clinical trial (NCT04702451) demonstrated superiority of targeting dispersion in addition to PVI identified by an artificial intelligence (AI) software over a PVI-only strategy i…
View article: Single center experience using a contact force sensing very high power short duration radiofrequency catheter for persistent atrial fibrillation guided with an artificial intelligence based software
Single center experience using a contact force sensing very high power short duration radiofrequency catheter for persistent atrial fibrillation guided with an artificial intelligence based software Open
Background/Introduction Recently, the TAILORED-AF randomized clinical trial (NCT04702451) demonstrated superiority of ablating persistent atrial fibrillation (AF) with the targeting of dispersion — identified by an artificial intelligence …
View article: Pulmonary vein isolation and low-voltage areas ablation in sinus rhythm for persistent atrial fibrillation (SCAR-AF study)
Pulmonary vein isolation and low-voltage areas ablation in sinus rhythm for persistent atrial fibrillation (SCAR-AF study) Open
Background Substrate ablation strategies in addition to pulmonary vein isolation (PVI) for the maintenance of sinus rhythm (SR) are still debated. Targeting low voltage areas (LVA) in addition to PVI may represent an efficient strategy for…
View article: Multicenter retrospective evaluation of a patient-tailored electrogram-based ablation strategy using an artificial intelligence software in repeat atrial fibrillation ablation procedures
Multicenter retrospective evaluation of a patient-tailored electrogram-based ablation strategy using an artificial intelligence software in repeat atrial fibrillation ablation procedures Open
Background While pulmonary vein isolation (PVI) is the gold standard approach of treatment of atrial fibrillation (AF), the optimal strategy in case of AF recurrences for redo patients is not well established. Several studies described the…
View article: BIDIRECTIONAL COMMUNICATION BETWEEN AN ARTIFICIAL INTELLIGENCE DEVICE AND A 3-DIMENSIONAL NAVIGATION APPARATUS IMPROVES AUTOMATION OF MULTIPOLAR ELECTROGRAM MAPPING DURING PAROXYSMAL AND PERSISTENT ATRIAL FIBRILLATION
BIDIRECTIONAL COMMUNICATION BETWEEN AN ARTIFICIAL INTELLIGENCE DEVICE AND A 3-DIMENSIONAL NAVIGATION APPARATUS IMPROVES AUTOMATION OF MULTIPOLAR ELECTROGRAM MAPPING DURING PAROXYSMAL AND PERSISTENT ATRIAL FIBRILLATION Open
Real-time artificial intelligence (AI) software design to detect dispersed electrograms (EGMs) during atrial fibrillation (AF) procedures has previously been described but a communication with a 3D mapping environment was missing.
View article: Artificial intelligence-enabled spatio-temporal dispersion mapping for persistent AF: Similarities and differences between pacing-induced or spontaneous AF
Artificial intelligence-enabled spatio-temporal dispersion mapping for persistent AF: Similarities and differences between pacing-induced or spontaneous AF Open
Funding Acknowledgements Type of funding sources: Other. Main funding source(s): Volta Medical Saint Joseph Hospital Marseille, France Background Spatiotemporal dispersion is an electrical footprint of atrial fibrillation (AF) drivers that…
View article: PO-03-102 BIATRIAL CHARACTERIZATION OF ARTIFICIAL-INTELLIGENCE IDENTIFIED SPATIOTEMPORAL DISPERSION IN PERSISTENT ATRIAL FIBRILLATION
PO-03-102 BIATRIAL CHARACTERIZATION OF ARTIFICIAL-INTELLIGENCE IDENTIFIED SPATIOTEMPORAL DISPERSION IN PERSISTENT ATRIAL FIBRILLATION Open
View article: Recurrences of Atrial Fibrillation Despite Durable Pulmonary Vein Isolation: The PARTY-PVI Study
Recurrences of Atrial Fibrillation Despite Durable Pulmonary Vein Isolation: The PARTY-PVI Study Open
Background: Recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI) are mainly due to pulmonary vein reconnection. However, a growing number of patients have AF recurrences despite durable PVI. The optimal ablative str…
View article: Cycle Length Estimation Using Accurate Adaptive Detection of Local Activations in Atrial Intracardiac Electrograms
Cycle Length Estimation Using Accurate Adaptive Detection of Local Activations in Atrial Intracardiac Electrograms Open
The normal electrical potential propagates throughout the atria periodically.During atrial arrhythmias its propagation is modified because the substrate is not homogeneous and new sources of punctual electrical activity appear.The periodic…
View article: A Machine Learning based approach for localization of Atrial Tachycardia origin
A Machine Learning based approach for localization of Atrial Tachycardia origin Open
Ablation procedures targeting Atrial Tachycardia (AT) can be drastically facilitated if the origin of the abnormality is located in advance using electrocardiogram (ECG) signals.The ECG recordings contain so called P waves, which represent…
View article: Right atrial appendage firing in atrial fibrillation
Right atrial appendage firing in atrial fibrillation Open
Background The role of atrial fibrillation (AF) drivers located at the left atrium, superior vena cava, crista terminalis and coronary sinus (CS) is well established. While these regions are classically targeted during catheter ablation, t…
View article: Artificial intelligence software standardizes electrogram‐based ablation outcome for persistent atrial fibrillation
Artificial intelligence software standardizes electrogram‐based ablation outcome for persistent atrial fibrillation Open
Introduction Multiple groups have reported on the usefulness of ablating in atrial regions exhibiting abnormal electrograms during atrial fibrillation (AF). Still, previous studies have suggested that ablation outcomes are highly operator‐…
View article: Localized Atrial Tachycardia and Dispersion Regions in Atrial Fibrillation: Evidence of Spatial Concordance
Localized Atrial Tachycardia and Dispersion Regions in Atrial Fibrillation: Evidence of Spatial Concordance Open
Introduction: During atrial fibrillation (AF) ablation, it is generally considered that atrial tachycardia (AT) episodes are a consequence of ablation. Objective: To investigate the spatial relationship between localized AT episodes and di…
View article: Percutaneous Left Atrial Appendage Closure Is a Reasonable Option for Patients With Atrial Fibrillation at High Risk for Cerebrovascular Events
Percutaneous Left Atrial Appendage Closure Is a Reasonable Option for Patients With Atrial Fibrillation at High Risk for Cerebrovascular Events Open
Background— Percutaneous left atrial appendage (LAA) closure is an emerging option for patients with atrial fibrillation at high risk for cerebrovascular events. The multicenter FLAAC registry (French Nationwide Observational LAA Closure R…
View article: AF Ablation Guided by Spatiotemporal Electrogram Dispersion Without Pulmonary Vein Isolation
AF Ablation Guided by Spatiotemporal Electrogram Dispersion Without Pulmonary Vein Isolation Open