Corinne Isenegger
YOU?
Author Swipe
View article: Anterior mitral isthmus line using pulsed-field ablation with the pentaspline catheter or radiofrequency ablation: procedural characteristics, safety, and mid-term outcomes
Anterior mitral isthmus line using pulsed-field ablation with the pentaspline catheter or radiofrequency ablation: procedural characteristics, safety, and mid-term outcomes Open
Aims Pulsed-field ablation (PFA) is a non-thermal energy source for pulmonary vein isolation (PVI), offering advantages in safety and procedural efficiency. However, data comparing anterior mitral isthmus line (MIL) ablation using PFA vs. …
View article: Feasibility and accuracy of wearable electrocardiogram monitoring in adult congenital heart disease
Feasibility and accuracy of wearable electrocardiogram monitoring in adult congenital heart disease Open
View article: Sex differences in procedural characteristics, safety, and clinical outcomes of pulsed field ablation for atrial fibrillation
Sex differences in procedural characteristics, safety, and clinical outcomes of pulsed field ablation for atrial fibrillation Open
View article: Comparison of Two Different Pulsed Field Ablation Systems: The Dual Pulse System Study
Comparison of Two Different Pulsed Field Ablation Systems: The Dual Pulse System Study Open
Background Recently, multiple pulsed field ablation (PFA)‐system were introduced for catheter ablation (CA) of atrial fibrillation (AF). However, data comparing procedural performance, the extent of low‐voltage areas (LVA), and myocardial …
View article: Comparative analysis of newest-generation variable-diameter cryoballoon with pulsed-field ablation for the treatment of atrial fibrillation: the CRYO-PULSE Study
Comparative analysis of newest-generation variable-diameter cryoballoon with pulsed-field ablation for the treatment of atrial fibrillation: the CRYO-PULSE Study Open
View article: Impact of left atrial anatomy on pulmonary vein isolation with cryoballoon ablation: Insights from the randomized controlled COMPARE CRYO study
Impact of left atrial anatomy on pulmonary vein isolation with cryoballoon ablation: Insights from the randomized controlled COMPARE CRYO study Open
View article: Pulsed-field ablation versus radiofrequency ablation in patients undergoing repeat catheter ablation for atrial fibrillation
Pulsed-field ablation versus radiofrequency ablation in patients undergoing repeat catheter ablation for atrial fibrillation Open
In patients undergoing repeat CA after thermal PVI, PFA resulted in similar procedural characteristics, safety, and arrythmia-free survival compared with RFA.
View article: Use of guideline-directed medical heart failure therapy in patients with suspected arrhythmia-induced cardiomyopathy
Use of guideline-directed medical heart failure therapy in patients with suspected arrhythmia-induced cardiomyopathy Open
View article: Inconclusive Single-Lead ECGs From Smart-Devices
Inconclusive Single-Lead ECGs From Smart-Devices Open
Automated rhythm classification is highly susceptible to baseline ECG anomalies. This study provides insights into the most appropriate patient population for smart device-based arrhythmia monitoring and offers guidance for selecting the o…
View article: Catheter ablation for atrial fibrillation in patients with tricuspid regurgitation
Catheter ablation for atrial fibrillation in patients with tricuspid regurgitation Open
View article: Long-term follow up of single-chamber atrial pacing—system upgrade and Wenckebach block point behavior: potential implications for leadless AAI pacing?
Long-term follow up of single-chamber atrial pacing—system upgrade and Wenckebach block point behavior: potential implications for leadless AAI pacing? Open
Background Single chamber atrial pacing (AAI) provides a disease-specific treatment for sick sinus syndrome (SSS) but has largely been replaced by DDD pacing. With the advent of leadless atrial pacemakers (PM), there is growing interest in…
View article: Catheter ablation for atrial fibrillation in patients with tricuspid regurgitation
Catheter ablation for atrial fibrillation in patients with tricuspid regurgitation Open
Introduction Contemporary guidelines recommend early rhythm control strategies including catheter ablation (CA) for patients with symptomatic atrial fibrillation. The impact of coexisting tricuspid regurgitation (TR) on procedural characte…
View article: Initial findings from an online diagnostic service for smart device ECGs: insights from an online wearable clinic
Initial findings from an online diagnostic service for smart device ECGs: insights from an online wearable clinic Open
Introduction A large amount of ECG data is now being generated by smart devices. The use of such devices by patients and healthy individuals is growing exponentially. There is an unmet need for well-organized programs to handle the large a…
View article: Pulsed-field ablation versus radiofrequency ablation in patients undergoing repeat catheter ablation for atrial fibrillation
Pulsed-field ablation versus radiofrequency ablation in patients undergoing repeat catheter ablation for atrial fibrillation Open
Background Pulsed-field ablation (PFA) is non-inferior compared to thermal energy sources such as radiofrequency ablation (RFA) or cryoballoon ablation for de novo pulmonary vein isolation (PVI). However, its potential value for repeat cat…
View article: Temporal patterns of atrial fibrillation recurrence after catheter ablation using pulsed-field ablation
Temporal patterns of atrial fibrillation recurrence after catheter ablation using pulsed-field ablation Open
Background The prognostic implications of temporal patterns of atrial fibrillation (AF) recurrence after catheter ablation might differ between thermal and non-thermal energy sources such as pulsed-field ablation (PFA). While recurrence of…
View article: Pulsed-field ablation versus cryoballoon ablation in patients with persistent atrial fibrillation undergoing first catheter ablation
Pulsed-field ablation versus cryoballoon ablation in patients with persistent atrial fibrillation undergoing first catheter ablation Open
Background Catheter ablation (CA) for persistent atrial fibrillation (AF) is more challenging and associated with less favorable outcomes. While early studies showed similar outcomes for pulsed-field ablation (PFA) and cryoballoon ablation…
View article: Pulsed-field ablation versus cryoballoon ablation in patients with persistent atrial fibrillation
Pulsed-field ablation versus cryoballoon ablation in patients with persistent atrial fibrillation Open
View article: Initial experience using a novel cryoballoon with variable balloon sizing - The ICE AGE FIT study -
Initial experience using a novel cryoballoon with variable balloon sizing - The ICE AGE FIT study - Open
View article: Procedural Characteristics, Extent of Acute Antral Lesion Size, and Myocardial Injury with Two Different Pulsed Field Ablation Systems - The Dual Pulse System Study
Procedural Characteristics, Extent of Acute Antral Lesion Size, and Myocardial Injury with Two Different Pulsed Field Ablation Systems - The Dual Pulse System Study Open
View article: Extent of myocardial injury after pulmonary vein isolation using 3 different pulsed field ablation systems
Extent of myocardial injury after pulmonary vein isolation using 3 different pulsed field ablation systems Open
View article: Pulsed field ablation for atrial fibrillation with a novel simplified protocol: The PFA dose study
Pulsed field ablation for atrial fibrillation with a novel simplified protocol: The PFA dose study Open
The novel simplified PFA protocol was associated with increased procedural efficiency while maintaining noninferior efficacy and safety compared with the standard PFA protocol.
View article: Accuracy of Smartwatches for Atrial Fibrillation Detection Over Time
Accuracy of Smartwatches for Atrial Fibrillation Detection Over Time Open
View article: Novel vs established cryoballoon ablation system for atrial fibrillation: A systematic review and meta-analysis
Novel vs established cryoballoon ablation system for atrial fibrillation: A systematic review and meta-analysis Open
The novel POLARx system provided similar efficiency and acute/long-term efficacy but showed a higher incidence of phrenic nerve palsies compared with the ArcticFront system.
View article: Procedural characteristics, safety, and clinical outcomes of pulsed-field ablation for pulmonary vein isolation in patients with a left common pulmonary vein
Procedural characteristics, safety, and clinical outcomes of pulsed-field ablation for pulmonary vein isolation in patients with a left common pulmonary vein Open
View article: Clinical validation of an artificial intelligence algorithm offering automated corrected QT-interval measurements from a single lead electrocardiogram
Clinical validation of an artificial intelligence algorithm offering automated corrected QT-interval measurements from a single lead electrocardiogram Open
Introduction A novel smartwatch (Withings Scanwatch, SW) offers automated analysis of the QTc based on single-lead ECG recordings. Prior clinical validation studies showed insufficient accuracy when compared to manual measurements based on…
View article: Diagnostic accuracy of smartwatches for automated atrial fibrillation detection over time: insights from the basel wearable study
Diagnostic accuracy of smartwatches for automated atrial fibrillation detection over time: insights from the basel wearable study Open
Background The first smart-watch (SW) able to record a single lead ECG (SL-ECG) with automated atrial fibrillation (AF) detection algorithm was introduced 2018. Multiple other manufacturers followed. While manufacturers claim to continuous…
View article: Posterior wall isolation with pulsed field ablation or radiofrequency ablation with vein of marshall ethanol ablation for the treatment of atrial fibrillation
Posterior wall isolation with pulsed field ablation or radiofrequency ablation with vein of marshall ethanol ablation for the treatment of atrial fibrillation Open
Background In patients undergoing repeat catheter ablation for atrial fibrillation (AF) two ablation strategies beyond pulmonary vein isolation (PVI) have recently gained increased interest: posterior wall isolation (PWI) using pulsed fiel…
View article: Acute kidney injury after catheter ablation of atrial fibrillation: Comparison between different energy sources
Acute kidney injury after catheter ablation of atrial fibrillation: Comparison between different energy sources Open
Pulsed field ablation (PFA) is an innovative technology recently adopted for treating atrial fibrillation (AF). Preclinical and clinical studies have reported a reassuring safety profile because of its tissue-specific effect, sparing adjac…
View article: Role of 3D electro-anatomical mapping on procedural characteristics and outcomes in pulsed-field ablation for atrial fibrillation
Role of 3D electro-anatomical mapping on procedural characteristics and outcomes in pulsed-field ablation for atrial fibrillation Open
[Figure: see text]
View article: Impact of implantation depth and calcium burden on infranodal conduction delay after transcatheter aortic valve replacement
Impact of implantation depth and calcium burden on infranodal conduction delay after transcatheter aortic valve replacement Open