D. V. N. Ananth
YOU?
Author Swipe
View article: Power Quality Enhancement in Distribution Networks with Pmsg Renewable Energy Integration with Nonlinear Loads Using Advanced Intelligent Controllers
Power Quality Enhancement in Distribution Networks with Pmsg Renewable Energy Integration with Nonlinear Loads Using Advanced Intelligent Controllers Open
View article: Chaotic Atom Search Optimized Fractional-Order Proportional-Integral-Derivative Control for Energy-Efficient Electric Vehicles Regenerative Braking
Chaotic Atom Search Optimized Fractional-Order Proportional-Integral-Derivative Control for Energy-Efficient Electric Vehicles Regenerative Braking Open
View article: Enhancing Low Voltage Ride-Through Resilience in Grid-Connected Doubly-Fed-Induction-Generator with Sliding Mode Controller
Enhancing Low Voltage Ride-Through Resilience in Grid-Connected Doubly-Fed-Induction-Generator with Sliding Mode Controller Open
In power systems, grid disturbances are prevalent, causing significant challenges for Doubly-Fed Induction Generators (DFIGs). During these disturbances, the windings of DFIGs are exposed to large offset inrush currents, which can damage t…
View article: A Metaheuristic Optimized Scheduling Algorithm Using Moscoa with Levy Flight for Efficient Task Allocation in Heterogeneous Systems
A Metaheuristic Optimized Scheduling Algorithm Using Moscoa with Levy Flight for Efficient Task Allocation in Heterogeneous Systems Open
View article: Analysis of Solar Photo-Voltaic Cell and Battery Energy Storage System Connected to a Dc Micro Grid Using Adaptive Fuzzy- Pid Controller
Analysis of Solar Photo-Voltaic Cell and Battery Energy Storage System Connected to a Dc Micro Grid Using Adaptive Fuzzy- Pid Controller Open
View article: Sustained Operation for Low and High Voltage Ride Through for Dfig Using Improved Field Oriented Control Technique
Sustained Operation for Low and High Voltage Ride Through for Dfig Using Improved Field Oriented Control Technique Open
View article: Power Quality Enhancement in Distribution Networks with Pmsg Renewable Energy Integration with Nonlinear Loads Using Advanced Intelligent Controllers
Power Quality Enhancement in Distribution Networks with Pmsg Renewable Energy Integration with Nonlinear Loads Using Advanced Intelligent Controllers Open
View article: Performance Enhancement of Doubly Fed Induction Generator–Based Wind Farms With STATCOM in Faulty HVDC Grids
Performance Enhancement of Doubly Fed Induction Generator–Based Wind Farms With STATCOM in Faulty HVDC Grids Open
In this study, an investigation of different faults for a wind turbine–based doubly fed induction generator (DFIG) system is studied and the performance using a static compensator (STATCOM) is observed. The DFIG network is connected to a v…
View article: Independent Active and Reactive Power Control for Single Stage H8 Transformer-less Solar PV Inverter
Independent Active and Reactive Power Control for Single Stage H8 Transformer-less Solar PV Inverter Open
With the rapid development in power electronics technologies and solar photovoltaic (PV) cells, the interest in solar PV cell-based electric power generation and other applications is increasing more incredibly. For low power grid or direc…
View article: Use of Super Conductor Magnetic Energy Storage System and FACTS Devices for Two-Area Load Frequency Control Having Synchronous Generators and DFIG Wind Generators
Use of Super Conductor Magnetic Energy Storage System and FACTS Devices for Two-Area Load Frequency Control Having Synchronous Generators and DFIG Wind Generators Open
The load change in a synchronous generator (SG) based power generation system is common which will mainly influence the change in voltage, power flows, frequency, load angle and burden of transmission lines and transformers due to change i…
View article: A Common Capacitor Based Three Level STATCOM and Design of DFIG Converter for a Zero-Voltage Fault Ride-Through Capability
A Common Capacitor Based Three Level STATCOM and Design of DFIG Converter for a Zero-Voltage Fault Ride-Through Capability Open
To meet the augmented load power demand, the doubly-fed induction generator (DFIG) based wind electrical power conversion system (WECS) is a better alternative. Further, to enhance the power flow capability and raise security margin in the…
View article: Application of CUK and ZETA Dc-Dc Choppers for Power Factor Correction and Power Quality Improvement of BLDC Motor
Application of CUK and ZETA Dc-Dc Choppers for Power Factor Correction and Power Quality Improvement of BLDC Motor Open
For industrial, electrical vehicles, drives, and grid applications ac-dc based inverters with power factor correction is considered as a key element to meet the power system firm regulatory rules. Among these dc-ac inverters, bridgeless co…
View article: Modeling and Design of Cascaded h-bridge type multi-level Inverters up to Thirty-one level for the Reduction and Performance Improvement
Modeling and Design of Cascaded h-bridge type multi-level Inverters up to Thirty-one level for the Reduction and Performance Improvement Open
Multilevel inverter (MLI) becomes more popular in high voltage DC (HVDC) applications, power electronic converters and drives. This paper describes the simulation of single phase multilevel cascaded H-bridge inverter. Simulation of three l…
View article: Smart Electricity Billing Using Node-MCU
Smart Electricity Billing Using Node-MCU Open
There are many problems in metering and billing processes like the going of meter reader to each customer meter to manually take the meter reading, the probability of the non-existence of the customers at their homes during that time, the …
View article: Design of DFIG Converters to Overcome Grid Faults Using Improved Stator Flux Based Field Oriented Control and STATCOM Controller
Design of DFIG Converters to Overcome Grid Faults Using Improved Stator Flux Based Field Oriented Control and STATCOM Controller Open
View article: Sustainable operation and performance improvement of grid connected DFIG during symmetrical faults using fuzzy controller based enhanced field oriented control
Sustainable operation and performance improvement of grid connected DFIG during symmetrical faults using fuzzy controller based enhanced field oriented control Open
According to modern grid regulations, doubly fed induction generator (DFIG) needs to operate without losing synchronism during grid faults. But, severe fault leads to rise in stator and rotor current to a higher value and generator will ge…
View article: Tip Speed Ratio Based MPPT Algorithm and Improved Field Oriented Control for Extracting Optimal Real power and Independent Reactive Power Control for Grid Connected Doubly Fed Induction Generator
Tip Speed Ratio Based MPPT Algorithm and Improved Field Oriented Control for Extracting Optimal Real power and Independent Reactive Power Control for Grid Connected Doubly Fed Induction Generator Open
Doubly Fed Induction Generator (DFIG) needs to get adopted to change in wind speeds with sudden change in reactive power or grid terminal voltage as it is required for maintaining synchronism and stability as per modern grid rules. This pa…
View article: Mitigation of voltage dip and power system oscillations damping using dual STATCOM for grid connected DFIG
Mitigation of voltage dip and power system oscillations damping using dual STATCOM for grid connected DFIG Open
View article: Flux Based Sensorless Speed Sensing and Real and Reactive Power Flow Control with Look-up Table based Maximum Power Point Tracking Technique for Grid Connected Doubly Fed Induction Generator
Flux Based Sensorless Speed Sensing and Real and Reactive Power Flow Control with Look-up Table based Maximum Power Point Tracking Technique for Grid Connected Doubly Fed Induction Generator Open
This aim of this paper is to design controller for Doubly Fed Induction Generator (DFIG) converters and MPPT for turbine and a sensor-less rotor speed estimation to maintain equilibrium in rotor speed, generator torque, and stator and roto…
View article: Reference power extraction based MPPT technique with enhanced real and reactive power flow control for grid connected DFIG
Reference power extraction based MPPT technique with enhanced real and reactive power flow control for grid connected DFIG Open
Doubly Fed Induction Generator (DFIG) needs to get adopted to change in wind speeds with sudden change in reactive power or grid terminal voltage as it is required for maintaining synchronism and stability as per modern grid rules. This pa…