David Reiners
YOU?
Author Swipe
View article: Left atrial low-voltage areas, but not volume, predict the recurrence of atrial fibrillation in repeat ablation procedures
Left atrial low-voltage areas, but not volume, predict the recurrence of atrial fibrillation in repeat ablation procedures Open
Background Left atrial (LA) low voltage areas (LVA) are a controversial target in atrial fibrillation ablation procedures. However, LVA and LA volume are good predictors of arrhythmia recurrence in ablation-naïve patients. Their predictive…
View article: Predictive value of guideline-referred risk scores in estimating left atrial low voltage areas and recurrence of atrial fibrillation in repeat ablation procedures
Predictive value of guideline-referred risk scores in estimating left atrial low voltage areas and recurrence of atrial fibrillation in repeat ablation procedures Open
Background Despite advances in mapping and ablation techniques, atrial fibrillation (AF) recurrence remains a challenge after pulmonary vein isolation. Low voltage areas (LVA) in the left atrium are associated with higher recurrence rates …
View article: Protocol: Ablation in patients with atrial fibrillation: A systematic review and meta-analysis of recurrence monitoring characteristics over the last decade
Protocol: Ablation in patients with atrial fibrillation: A systematic review and meta-analysis of recurrence monitoring characteristics over the last decade Open
Review question / Objective -How is the recurrence of atrial fibrillation after catheter ablation therapy defined and monitored in randomized-controlled clinical studies in the past ten years?Do the monitoring characteristics have an impac…
View article: Direct Flow Medical vs. Edwards Sapien 3 Prosthesis: A Propensity Matched Comparison on Intermediate Safety and Mortality
Direct Flow Medical vs. Edwards Sapien 3 Prosthesis: A Propensity Matched Comparison on Intermediate Safety and Mortality Open
Aims: To compare intermediate performance and mortality rates in patients, who underwent transcatheter aortic valve implantation (TAVI) with two different types of prostheses: Edwards Sapien 3 (ES3) and Direct Flow Medical (DFM). Methods a…
View article: Risk of endoscopic biliary interventions in primary sclerosing cholangitis is similar between patients with and without cirrhosis
Risk of endoscopic biliary interventions in primary sclerosing cholangitis is similar between patients with and without cirrhosis Open
In patients with PSC, cirrhosis was not a risk factor for post-ERC complications. Therefore, cirrhosis should not preclude endoscopic intervention in patients with clear clinical indication.