Edmond Sterpin
YOU?
Author Swipe
View article: Dynamic proton arc treatment planning study for oesophageal cancer
Dynamic proton arc treatment planning study for oesophageal cancer Open
Particle Arc Therapy (PAT) is considered a promising technique to improve conformity and reduce toxicities. Robustly optimized PAT plans were evaluated versus Intensity Modulated Proton Therapy (IMPT) for oesophageal cancer in 17 patients.…
View article: Towards faster plan adaptation for proton arc therapy using initial treatment plan information
Towards faster plan adaptation for proton arc therapy using initial treatment plan information Open
Smart-adapted plans achieve similar plan quality to the reference method, while significantly reducing plan generation time for new patient anatomy.
View article: Robustness Evaluation in proton therapy: An ESTRO Delphi consensus
Robustness Evaluation in proton therapy: An ESTRO Delphi consensus Open
View article: Potential of automated online adaptive proton therapy to reduce margins for oesophageal cancer
Potential of automated online adaptive proton therapy to reduce margins for oesophageal cancer Open
View article: Treatment Planning Study for Oesophageal Cancer: Dynamic Proton Arc vs Conventional Intensity Modulated Proton Therapy
Treatment Planning Study for Oesophageal Cancer: Dynamic Proton Arc vs Conventional Intensity Modulated Proton Therapy Open
View article: A dosimetric and robustness analysis of proton arc therapy with early energy layer and spot assignment for lung cancer versus conventional intensity modulated proton therapy
A dosimetric and robustness analysis of proton arc therapy with early energy layer and spot assignment for lung cancer versus conventional intensity modulated proton therapy Open
Background and purpose: Intensity Modulated Proton Therapy (IMPT) faces challenges in lung cancer treatment, like maintaining plan robustness for moving tumors against setup, range errors, and interplay effects. Proton Arc Therapy (PAT) is…
View article: A comparative study on automatic treatment planning for online adaptive proton therapy of esophageal cancer: which combination of deformable registration and deep learning planning tools performs the best?
A comparative study on automatic treatment planning for online adaptive proton therapy of esophageal cancer: which combination of deformable registration and deep learning planning tools performs the best? Open
Objective. To demonstrate the feasibility of integrating fully-automated online adaptive proton therapy strategies (OAPT) within a commercially available treatment planning system and underscore what limits their clinical implementation. T…
View article: A dosimetric and robustness analysis of Proton Arc Therapy (PAT) with Early Energy Layer and Spot Assignment (ELSA) for lung cancer versus conventional Intensity modulated therapy (IMPT)
A dosimetric and robustness analysis of Proton Arc Therapy (PAT) with Early Energy Layer and Spot Assignment (ELSA) for lung cancer versus conventional Intensity modulated therapy (IMPT) Open
Background and purpose: IMPT faces challenges in lung cancer treatment, like maintaining plan robustness for moving tumors against setup, range errors, and interplay effects. Proton Arc Therapy (PAT) is an alternative to maintain target co…
View article: Phase-change ultrasound contrast agents for proton range verification: towards an in vivo application
Phase-change ultrasound contrast agents for proton range verification: towards an in vivo application Open
Objective. In proton therapy, range uncertainties prevent optimal benefit from the superior depth-dose characteristics of proton beams over conventional photon-based radiotherapy. To reduce these uncertainties we recently proposed the use …
View article: Autodelineation methods in a simulated fully automated proton therapy workflow for esophageal cancer
Autodelineation methods in a simulated fully automated proton therapy workflow for esophageal cancer Open
View article: Monte Carlo simulation of initial and volume ion recombination correction factor in plane parallel ionization chambers exposed to ion beams
Monte Carlo simulation of initial and volume ion recombination correction factor in plane parallel ionization chambers exposed to ion beams Open
Objective. Accurate reference dosimetry with ionization chambers (ICs) relies on correcting for various influencing factors, including ion recombination. Theoretical frameworks, such as the Boag and Jaffe theories, are conventionally used …
View article: Time is NTCP: Should we maximize patient throughput or perform online adaptation on proton therapy systems?
Time is NTCP: Should we maximize patient throughput or perform online adaptation on proton therapy systems? Open
View article: PROTON FLASH IRRADIATION SPARES ZEBRAFISH EMBRYOS FROM RADIATION-INDUCED DNA DAMAGE AND RESULTS IN REDUCED LEVELS OF APOPTOSIS AND INFLAMMATION
PROTON FLASH IRRADIATION SPARES ZEBRAFISH EMBRYOS FROM RADIATION-INDUCED DNA DAMAGE AND RESULTS IN REDUCED LEVELS OF APOPTOSIS AND INFLAMMATION Open
View article: TOWARDS FAST PLAN ADAPTATION FOR PROTON ARC THERAPY
TOWARDS FAST PLAN ADAPTATION FOR PROTON ARC THERAPY Open
View article: PARROT: A USER-FRIENDLY WEB PLATFORM FOR AI-DRIVEN RADIATION THERAPY PLANNING
PARROT: A USER-FRIENDLY WEB PLATFORM FOR AI-DRIVEN RADIATION THERAPY PLANNING Open
View article: Robustness evaluation of pencil beam scanning proton therapy treatment planning: A systematic review
Robustness evaluation of pencil beam scanning proton therapy treatment planning: A systematic review Open
View article: ADAPTIVE RADIOTHERAPY FOR ESOPHAGEAL CANCER PATIENTS: ADAPTATION RATES AND BENEFITS
ADAPTIVE RADIOTHERAPY FOR ESOPHAGEAL CANCER PATIENTS: ADAPTATION RATES AND BENEFITS Open
View article: NEW CORRECTION FACTOR FOR IONIZATION CHAMBERS EXPOSED TO ULTRA-HIGH DOSE RATE PER PULSE PROTON BEAMS
NEW CORRECTION FACTOR FOR IONIZATION CHAMBERS EXPOSED TO ULTRA-HIGH DOSE RATE PER PULSE PROTON BEAMS Open
View article: ENERGY LAYER PRE-SELECTION FOR PROTON ARC THERAPY: BALANCING DELIVERY TIME AND GEOMETRICAL COVERAGE
ENERGY LAYER PRE-SELECTION FOR PROTON ARC THERAPY: BALANCING DELIVERY TIME AND GEOMETRICAL COVERAGE Open
View article: A Preliminary Investigation of Radiation-Sensitive Ultrasound Contrast Agents for Photon Dosimetry
A Preliminary Investigation of Radiation-Sensitive Ultrasound Contrast Agents for Photon Dosimetry Open
Radiotherapy treatment plans have become highly conformal, posing additional constraints on the accuracy of treatment delivery. Here, we explore the use of radiation-sensitive ultrasound contrast agents (superheated phase-change nanodrople…
View article: Efficient proton arc optimization and delivery through energy layer pre‐selection and post‐filtering
Efficient proton arc optimization and delivery through energy layer pre‐selection and post‐filtering Open
Background Proton arc therapy (PAT) has emerged as a promising approach for improving dose distribution, but also enabling simpler and faster treatment delivery in comparison to conventional proton treatments. However, the delivery speed a…
View article: Evaluation of safety margins for cone beam CT-based adaptive prostate radiotherapy
Evaluation of safety margins for cone beam CT-based adaptive prostate radiotherapy Open
View article: Balancing robustness and adaptation rate for proton therapy of lung cancer patients
Balancing robustness and adaptation rate for proton therapy of lung cancer patients Open
View article: Markerless liver online adaptive stereotactic radiotherapy: feasibility analysis
Markerless liver online adaptive stereotactic radiotherapy: feasibility analysis Open
Objective . Radio-opaque markers are recommended for image-guided radiotherapy in liver stereotactic ablative radiotherapy (SABR), but their implantation is invasive. We evaluate in this in-silico study the feasibility of cone-beam compute…
View article: DIVE-ART: A tool to guide clinicians towards dosimetrically informed volume editions of automatically segmented volumes in adaptive radiation therapy
DIVE-ART: A tool to guide clinicians towards dosimetrically informed volume editions of automatically segmented volumes in adaptive radiation therapy Open
View article: Fast Plan Adaptation for Proton Arc Therapy Using Initial Treatment Plan Information
Fast Plan Adaptation for Proton Arc Therapy Using Initial Treatment Plan Information Open
View article: Comparison of Ethos template-based planning and AI-based dose prediction: General performance, patient optimality, and limitations
Comparison of Ethos template-based planning and AI-based dose prediction: General performance, patient optimality, and limitations Open
View article: Technical note: Beamlet‐free optimization for Monte‐Carlo‐based treatment planning in proton therapy
Technical note: Beamlet‐free optimization for Monte‐Carlo‐based treatment planning in proton therapy Open
Background Dose calculation and optimization algorithms in proton therapy treatment planning often have high computational requirements regarding time and memory. This can hinder the implementation of efficient workflows in clinics and pre…
View article: Efficient proton arc optimization and delivery through energy layer pre-selection and post-filtering
Efficient proton arc optimization and delivery through energy layer pre-selection and post-filtering Open
Proton arc therapy (PAT) has emerged as a promising approach for improving dose distribution, but also enabling simpler and faster treatment delivery in comparison to conventional proton treatments. However, the delivery speed achievable i…
View article: A spot‐specific range uncertainty framework for robust optimization of proton therapy treatments
A spot‐specific range uncertainty framework for robust optimization of proton therapy treatments Open
Purpose An accurate estimation of range uncertainties is essential to exploit the potential of proton therapy. According to Paganetti's study, a value of 2.4% (1.5 standard deviation) is currently recommended for planning robust treatments…