View article: Linear accelerator-based stereotactic radiosurgery for glossopharyngeal neuralgia is safe and effective - Report of two cases.
Linear accelerator-based stereotactic radiosurgery for glossopharyngeal neuralgia is safe and effective - Report of two cases. Open
View article: Assessment of the use of different imaging and delivery techniques for cranial treatments on the Halcyon linac
Assessment of the use of different imaging and delivery techniques for cranial treatments on the Halcyon linac Open
Purpose In this work, we investigated the effect on the workflow and setup accuracy of using surface guided radiation therapy (SGRT) for patient setup, megavoltage cone beam CT (MVCBCT) or kilovoltage cone beam CT (kVCBCT) for imaging and …
View article: Dosimetric study of the plan quality and dose to organs at risk on tangential breast treatments using the Halcyon linac
Dosimetric study of the plan quality and dose to organs at risk on tangential breast treatments using the Halcyon linac Open
Purpose To investigate the plan quality and doses to the heart, contralateral breast (CB), ipsilateral lung (IL), and contralateral lung (CL) in tangential breast treatments using the Halcyon linac with megavoltage setup fields. Methods Ra…
View article: Characterization of the Halcyon<sup>TM</sup> multileaf collimator system
Characterization of the Halcyon<sup>TM</sup> multileaf collimator system Open
Purpose To characterize the stacked and staggered dual‐layer multileaf collimator ( MLC ) on the Halcyon TM system. Methods The novel MLC assembly was reviewed and compared to the widely used Millennium TM 120‐leaf MLC system. We investiga…
View article: <scp>TG</scp>‐51 reference dosimetry for the Halcyon™: A clinical experience
<span>TG</span>‐51 reference dosimetry for the Halcyon™: A clinical experience Open
Halcyon™ is a single‐energy (6 MV ‐ FFF ), bore‐enclosed linear accelerator. Patient setup is performed by first aligning to external lasers mounted to the front of the bore, and then loading to isocenter through pre‐defined couch shifts. …
View article: Challenges and opportunities in calorimetry for clinical radiation dosimetry
Challenges and opportunities in calorimetry for clinical radiation dosimetry Open
Primary Standard Dosimetry Laboratories establish the standards of absorbed dose to water (ADW) using calorimetry. This is because calorimetry is the most direct method to account for the energy imparted to matter by radiation. The traditi…