Fabian Kording
YOU?
Author Swipe
View article: Doppler ultrasound gating for adult cardiovascular magnetic resonance: Initial experience
Doppler ultrasound gating for adult cardiovascular magnetic resonance: Initial experience Open
CMR gating with DUS is feasible and can offer an equivalent performance to ECG regarding image quality and quantitative parameter assessment.
View article: Fetal Cardiac MRI Using Doppler US Gating: Emerging Technology and Clinical Implications
Fetal Cardiac MRI Using Doppler US Gating: Emerging Technology and Clinical Implications Open
Fetal cardiac MRI using Doppler US gating is an emerging technique to support prenatal diagnosis of congenital heart disease and other cardiovascular abnormalities. Analogous to postnatal electrocardiographically gated cardiac MRI, this te…
View article: The Evolution and Developing Importance of Fetal Magnetic Resonance Imaging in the Diagnosis of Congenital Cardiac Anomalies: A Systematic Review
The Evolution and Developing Importance of Fetal Magnetic Resonance Imaging in the Diagnosis of Congenital Cardiac Anomalies: A Systematic Review Open
Magnetic Resonance Imaging (MRI) is a reliable method, with a complementary role to Ultrasound (US) Echocardiography, that can be used to fully comprehend and precisely diagnose congenital cardiac malformations. Besides the anatomical stud…
View article: Fetal 4D flow MRI of the great thoracic vessels at 3 Tesla using Doppler-ultrasound gating: a feasibility study
Fetal 4D flow MRI of the great thoracic vessels at 3 Tesla using Doppler-ultrasound gating: a feasibility study Open
View article: Correction to: Quantification of blood flow in the fetus with cardiovascular magnetic resonance imaging using Doppler ultrasound gating: validation against metric optimized gating
Correction to: Quantification of blood flow in the fetus with cardiovascular magnetic resonance imaging using Doppler ultrasound gating: validation against metric optimized gating Open
View article: Doppler ultrasound cardiac gating of intracranial flow at 7T
Doppler ultrasound cardiac gating of intracranial flow at 7T Open
View article: VP15.13: Fetal cardiac 4D phase contrast MRI using Doppler ultrasound gating to visualise fetal hemodynamics <i>in utero</i>: preliminary results
VP15.13: Fetal cardiac 4D phase contrast MRI using Doppler ultrasound gating to visualise fetal hemodynamics <i>in utero</i>: preliminary results Open
The aim of this preliminary study was to evaluate the feasibility of 4D phase contrast magnetic resonance imaging to visualise fetal cardiac hemodynamics with the focus on the fetal aorta. The feasibility to acquire a 4D dataset of the aor…
View article: Fetal dynamic magnetic resonance imaging using Doppler ultrasound gating for the assessment of the aortic isthmus: A feasibility study
Fetal dynamic magnetic resonance imaging using Doppler ultrasound gating for the assessment of the aortic isthmus: A feasibility study Open
Introduction Cardiovascular magnetic resonance imaging (MRI) is established in cardiac evaluation in postnatal life, but its application to the fetus has been hampered by technical limitations. We aimed to investigate the feasibility of dy…
View article: OC21.03: Dynamic fetal cardiac magnetic resonance imaging using Doppler ultrasound gating in the assessment of the fetal aortic arch: a feasibility study in comparison to fetal echocardiography
OC21.03: Dynamic fetal cardiac magnetic resonance imaging using Doppler ultrasound gating in the assessment of the fetal aortic arch: a feasibility study in comparison to fetal echocardiography Open
To investigate the feasibility of dynamic fetal cardiac MRI using an MR compatible Doppler Ultrasound (DUS) device for fetal cardiac gating to evaluate the fetal aortic arch in comparison to fetal echocardiography. This was a prospective s…
View article: Free‐breathing fetal cardiac MRI with doppler ultrasound gating, compressed sensing, and motion compensation
Free‐breathing fetal cardiac MRI with doppler ultrasound gating, compressed sensing, and motion compensation Open
Background Fetal cardiovascular MRI complements ultrasound to assess fetal cardiovascular pathophysiology. Purpose To develop a free‐breathing method for retrospective fetal cine MRI using Doppler ultrasound (DUS) cardiac gating and tiny g…
View article: Monitoring of atherosclerotic plaque progression in ApoE KO mice: - a comparison of in vivo 7T MRI and ex vivo microCT
Monitoring of atherosclerotic plaque progression in ApoE KO mice: - a comparison of in vivo 7T MRI and ex vivo microCT Open
Poster: ECR 2019 / C-2713 / Monitoring of atherosclerotic plaque progression in ApoE KO mice: - a comparison of in vivo 7T MRI and ex vivo microCT by: C. Jung , M. Heine, M. Kaul, F. Kording, G. Adam, H. Ittrich; Hamburg/DE
View article: Quantification of blood flow in the fetus with cardiovascular magnetic resonance imaging using Doppler ultrasound gating: validation against metric optimized gating
Quantification of blood flow in the fetus with cardiovascular magnetic resonance imaging using Doppler ultrasound gating: validation against metric optimized gating Open
View article: Dynamic fetal cardiac magnetic resonance imaging in four‐chamber view using Doppler ultrasound gating in normal fetal heart and in congenital heart disease: comparison with fetal echocardiography
Dynamic fetal cardiac magnetic resonance imaging in four‐chamber view using Doppler ultrasound gating in normal fetal heart and in congenital heart disease: comparison with fetal echocardiography Open
Objectives To investigate the diagnostic performance of dynamic fetal cardiac magnetic resonance imaging (MRI), using a MR‐compatible Doppler ultrasound (DUS) device for fetal cardiac gating, in differentiating fetuses with congenital hear…
View article: Dynamic fetal cardiovascular magnetic resonance imaging using Doppler ultrasound gating
Dynamic fetal cardiovascular magnetic resonance imaging using Doppler ultrasound gating Open
View article: Evaluation of a Portable Doppler Ultrasound Gating Device for Fetal Cardiac MR Imaging: Initial Results at 1.5T and 3T
Evaluation of a Portable Doppler Ultrasound Gating Device for Fetal Cardiac MR Imaging: Initial Results at 1.5T and 3T Open
An MR conditional DUS gating device was developed and evaluated revealing safety, compatibility, and reliability for different field strengths. In a preliminary experience, the DUS device was successfully applied for in vivo fetal cardiac …
View article: Doppler Ultrasound Triggering for Cardiovascular MRI at 3T in a Healthy Volunteer Study
Doppler Ultrasound Triggering for Cardiovascular MRI at 3T in a Healthy Volunteer Study Open
This study demonstrated the feasibility of DUS for gating human CMR at 3T. The magnetohydrodynamic effect did not significantly disturb ECG triggering in this small healthy volunteer study. DUS showed a significant improvement in diastolic…
View article: Gadospin F—Enhanced Magnetic Resonance Imaging for Diagnosis and Monitoring of Atherosclerosis: Validation with Transmission Electron Microscopy and X-Ray Fluorescence Imaging in the Apolipoprotein E—Deficient Mouse
Gadospin F—Enhanced Magnetic Resonance Imaging for Diagnosis and Monitoring of Atherosclerosis: Validation with Transmission Electron Microscopy and X-Ray Fluorescence Imaging in the Apolipoprotein E—Deficient Mouse Open
The aim of this study was to investigate the feasibility of noninvasive monitoring of plaque burden in apolipoprotein E–deficient (ApoE −/− ) mice by Gadospin F (GDF)-enhanced magnetic resonance imaging (MRI). Gadolinium uptake in plaques …