Frans J. M. Harren
YOU?
Author Swipe
View article: 2025 photonics for agrifood roadmap: towards a sustainable and healthier planet
2025 photonics for agrifood roadmap: towards a sustainable and healthier planet Open
Photonics technologies play a crucial role in driving technological advancements within the agrifood industry, aiming to deliver a sustainable food and agriculture, and offering healthy, nutritious and safe food for all of us. Particularly…
View article: In-situ analysis of methane plasmas with mid-infrared supercontinuum-based Fourier-transform spectroscopy
In-situ analysis of methane plasmas with mid-infrared supercontinuum-based Fourier-transform spectroscopy Open
View article: Ultra-broadband spectroscopy using a 2–11.5 µm IDFG-based supercontinuum source
Ultra-broadband spectroscopy using a 2–11.5 µm IDFG-based supercontinuum source Open
Supercontinuum sources based on intrapulse difference frequency generation (IDFG) from mode-locked lasers open new opportunities in mid-infrared gas spectroscopy. These sources provide high power and ultra-broadband spectral coverage in th…
View article: Ultra-broadband spectroscopy using a 2–11.5 μm IDFG-based supercontinuum source
Ultra-broadband spectroscopy using a 2–11.5 μm IDFG-based supercontinuum source Open
Supercontinuum sources based on intrapulse difference frequency generation (IDFG) from mode-locked lasers open new opportunities in mid-infrared gas spectroscopy. These sources provide high power and ultra-broadband spectral coverage in th…
View article: Ultra-broadband spectroscopy using a 2–11.5 μm IDFG-based supercontinuum source
Ultra-broadband spectroscopy using a 2–11.5 μm IDFG-based supercontinuum source Open
Supercontinuum sources based on intrapulse difference frequency generation (IDFG) from mode-locked lasers open new opportunities in mid-infrared gas spectroscopy. These sources provide high power and ultra-broadband spectral coverage in th…
View article: Mid-infrared supercontinuum-based Fourier transform spectroscopy for plasma analysis
Mid-infrared supercontinuum-based Fourier transform spectroscopy for plasma analysis Open
View article: Mid-infrared Supercontinuum-based Fourier Transform Spectroscopy for plasma analysis
Mid-infrared Supercontinuum-based Fourier Transform Spectroscopy for plasma analysis Open
Broadband mid-infrared (MIR) spectroscopy is a well-established and valuable diagnostic technique for reactive plasmas. Plasmas are complex systems and consist of numerous (reactive) types of molecules; it is challenging to measure and con…
View article: Non-Invasive Monitoring of Inflammation in Inflammatory Bowel Disease Patients during Prolonged Exercise via Exhaled Breath Volatile Organic Compounds
Non-Invasive Monitoring of Inflammation in Inflammatory Bowel Disease Patients during Prolonged Exercise via Exhaled Breath Volatile Organic Compounds Open
The aim of this study was to investigate volatile organic compounds (VOCs) in exhaled breath as possible non-invasive markers to monitor the inflammatory response in inflammatory bowel disease (IBD) patients as a result of repeated and pro…
View article: Mid-infrared Broadband Spectroscopy for Plasma Analysis
Mid-infrared Broadband Spectroscopy for Plasma Analysis Open
We demonstrate the application of a home-built Fourier Transform Spectrometer based on a mid-infrared supercontinuum source for multispecies detection in a plasma reactor. The results show the high capability of the system for plasma analy…
View article: Fourier Transform Spectroscopy based on a Mid-Infrared Supercontinuum Source for Plasma Study
Fourier Transform Spectroscopy based on a Mid-Infrared Supercontinuum Source for Plasma Study Open
We present a home-built Fourier transform spectrometer based on two mid-infrared supercontinuum sources with spectral coverage between 1.4 - 7.5 μm for CH 4 plasma analysis and CO 2 /N 2 plasma product analysis.
View article: The peppermint breath test benchmark for PTR-MS and SIFT-MS
The peppermint breath test benchmark for PTR-MS and SIFT-MS Open
A major challenge for breath research is the lack of standardization in sampling and analysis. To address this, a test that utilizes a standardized intervention and a defined study protocol has been proposed to explore disparities in breat…
View article: Mid-infrared dual-comb absorption and dispersion spectroscopy and temperature measurement in a plasma
Mid-infrared dual-comb absorption and dispersion spectroscopy and temperature measurement in a plasma Open
\n Contains fulltext :\n 244834.pdf (Publisher’s version ) (Open Access)\n
View article: Fourier transform spectrometer developed for high repetition rate mid-infrared supercontinuum sources
Fourier transform spectrometer developed for high repetition rate mid-infrared supercontinuum sources Open
\n Contains fulltext :\n 240173.pdf (Publisher’s version ) (Open Access)\n
View article: Ultra-broadband infrared gas sensor for pollution detection: the TRIAGE project
Ultra-broadband infrared gas sensor for pollution detection: the TRIAGE project Open
Air pollution is one of the largest risk factors for disease or premature death globally, yet current portable monitoring technology cannot provide adequate protection at a local community level. Within the TRIAGE project, a smart, compact…
View article: Fourier transform spectrometer based on high-repetition-rate mid-infrared supercontinuum sources for trace gas detection
Fourier transform spectrometer based on high-repetition-rate mid-infrared supercontinuum sources for trace gas detection Open
We present a fast-scanning Fourier transform spectrometer (FTS) in combination with high-repetition-rate mid-infrared supercontinuum sources, covering a wavelength range of 2–10.5 µm. We demonstrate the performance of the spectrometer for …
View article: Exhaled Breath Reflects Prolonged Exercise and Statin Use during a Field Campaign
Exhaled Breath Reflects Prolonged Exercise and Statin Use during a Field Campaign Open
Volatile organic compounds (VOCs) in exhaled breath provide insights into various metabolic processes and can be used to monitor physiological response to exercise and medication. We integrated and validated in situ a sampling and analysis…
View article: Comment on amt-2021-28
Comment on amt-2021-28 Open
Abstract. We describe the Airborne Mid-Infrared Cavity enhanced Absorption spectrometer (AMICA) designed to measure trace gases in situ on research aircraft using Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS). A…
View article: Fourier transform and grating-based spectroscopy with a mid-infrared supercontinuum source for trace gas detection in fruit quality monitoring
Fourier transform and grating-based spectroscopy with a mid-infrared supercontinuum source for trace gas detection in fruit quality monitoring Open
We present a multi-species trace gas sensor based on a fast, compact home-built Fourier transform spectrometer (FTS) combined with a broadband mid-infrared supercontinuum (SC) source. The spectrometer covers the spectral bandwidth of the S…
View article: Airborne campaign results of a compact 2-4um broadband supercontinuum-based spectrometer system for multi-species atmospheric gas analysis at ppm level
Airborne campaign results of a compact 2-4um broadband supercontinuum-based spectrometer system for multi-species atmospheric gas analysis at ppm level Open
\n Contains fulltext :\n 244761.pdf (Publisher’s version ) (Open Access)\n
View article: Fourier Transform Spectroscopy Using Novel Mid-infrared Supercontinuum Sources
Fourier Transform Spectroscopy Using Novel Mid-infrared Supercontinuum Sources Open
We present a Fourier Transform Spectrometer, especially developed for ultra-broadband mid-infrared supercontinuum sources and suitable for multispecies trace gas detection with noise equivalent detection limits in the order of 0.3-10 ppmv …
View article: Broadband Time-Resolved Absorption and Dispersion Spectroscopy of Methane and Ethane in a Plasma Using a Mid-Infrared Dual-Comb Spectrometer
Broadband Time-Resolved Absorption and Dispersion Spectroscopy of Methane and Ethane in a Plasma Using a Mid-Infrared Dual-Comb Spectrometer Open
Conventional mechanical Fourier Transform Spectrometers (FTS) can simultaneously measure absorption and dispersion spectra of gas-phase samples. However, they usually need very long measurement times to achieve time-resolved spectra with a…
View article: Broadband Time-Resolved Absorption and Dispersion Spectroscopy of Methane and Ethane in A Plasma Using a Mid-Infrared Dual-Comb Spectrometer
Broadband Time-Resolved Absorption and Dispersion Spectroscopy of Methane and Ethane in A Plasma Using a Mid-Infrared Dual-Comb Spectrometer Open
Conventional mechanical Fourier Transform Spectrometers (FTS) are able to simultaneously measure absorption and dispersion spectra of gas-phase samples. However, they usually need very long measurement times to achieve time-resolved spectr…
View article: Sensitive multi-species trace gas sensor based on a high repetition rate mid-infrared supercontinuum source
Sensitive multi-species trace gas sensor based on a high repetition rate mid-infrared supercontinuum source Open
We present a multi-species trace gas sensor based on a high-repetition-rate mid-infrared supercontinuum source, in combination with a 30 m multipass absorption cell, and a scanning grating spectrometer. The output of the spectrometer is de…
View article: Cell death associated release of volatile organic sulphur compounds with antioxidant properties in chemical-challenged tobacco BY-2 suspension cultured cells
Cell death associated release of volatile organic sulphur compounds with antioxidant properties in chemical-challenged tobacco BY-2 suspension cultured cells Open
View article: New coherent sources for mid infrared spectroscopic applications
New coherent sources for mid infrared spectroscopic applications Open
An overview will be given on the new coherent sources that became available and can fulfil the needs for analytical spectroscopy in the mid infrared wavelength region. Recent highly-visible applications will be presented.
View article: Experimental-based comparison between off-axis integrated cavity output spectroscopy and multipass-assisted wavelength modulation spectroscopy at 77 µm
Experimental-based comparison between off-axis integrated cavity output spectroscopy and multipass-assisted wavelength modulation spectroscopy at 77 µm Open
\n Contains fulltext :\n 208090.pdf (Publisher’s version ) (Open Access)\n
View article: Mid-infrared supercontinuum-based upconversion detection for trace gas sensing
Mid-infrared supercontinuum-based upconversion detection for trace gas sensing Open
Recent advancements of mid-infrared (MIR) supercontinuum light sources have opened up new possibilities in laser-based trace gas sensing. While the supercontinuum sources inherently support wide spectral coverage, the detection of broadban…
View article: Mid-infrared dual-comb spectroscopy with absolute frequency calibration using a passive optical reference
Mid-infrared dual-comb spectroscopy with absolute frequency calibration using a passive optical reference Open
We demonstrate an absolute-frequency-calibrated mid-infrared dual-comb spectrometer by using a reference absorption cell. The source is based on a singly-resonant OPO containing two MgO:PPLN crystals in a common ring cavity, synchronously …
View article: A Broadband Mid-Infrared Trace Gas Sensor Using Supercontinuum Light Source: Applications for Real-Time Quality Control for Fruit Storage
A Broadband Mid-Infrared Trace Gas Sensor Using Supercontinuum Light Source: Applications for Real-Time Quality Control for Fruit Storage Open
We present a fully integrated and transportable multi-species trace gas sensor based on a mid-infrared (MIR) supercontinuum light source. The high brightness (surpassing synchrotron) and ultra-broad spectral bandwidth (2–4 μm) of this ligh…
View article: Light, Energy and the Environment, 2018: introduction to the joint feature issue
Light, Energy and the Environment, 2018: introduction to the joint feature issue Open
This joint feature issue of Optics Express and Applied Optics highlights contributions from authors who presented their latest research at the OSA Light, Energy and the Environment Congress, held in Sentosa Island, Singapore from 5 to 8 No…