Gavin Sutton
YOU?
Author Swipe
View article: Thermometry with embedded SI traceability for industrial applications
Thermometry with embedded SI traceability for industrial applications Open
Most industrial processes rely on temperature measurement, which directly influences product quality, energy efficiency, process optimization and emissions. The European Partnership on Metrology project “Thermometry with embedded SI tracea…
View article: Enhancing process efficiency through improved temperature measurement: the EMPRESS projects
Enhancing process efficiency through improved temperature measurement: the EMPRESS projects Open
EMPRESS 2 is a European project to enhance the efficiency of high value manufacturing processes by improving temperature measurement and control capability. This project seeks to address four contemporary thermometry challenges in this sec…
View article: Electromagnetic immune phosphor-tipped fibre-optic thermometers
Electromagnetic immune phosphor-tipped fibre-optic thermometers Open
Calibration traceability can be broken where there are significant, unquantified uncertainties. Thermometry in harsh environments using electrical sensors, such as thermocouples or resistance thermometers, can be unpredictably affected by …
View article: Electromagnetic immune phosphor-tipped fibre-optic thermometers
Electromagnetic immune phosphor-tipped fibre-optic thermometers Open
Calibration traceability can be broken where there are significant, unquantified uncertainties. Thermometry in harsh environments using electrical sensors, such as thermocouples or resistance thermometers, can be unpredictably affected by …
View article: Electromagnetic immune phosphor-tipped fibre-optic thermometers
Electromagnetic immune phosphor-tipped fibre-optic thermometers Open
Calibration traceability can be broken where there are significant, unquantified uncertainties. Thermometry in harsh environments using electrical sensors, such as thermocouples or resistance thermometers, can be unpredictably affected by …
View article: Electromagnetic immune phosphor-tipped fibre-optic thermometers
Electromagnetic immune phosphor-tipped fibre-optic thermometers Open
Calibration traceability can be broken where there are significant, unquantified uncertainties. Thermometry in harsh environments using electrical sensors, such as thermocouples or resistance thermometers, can be unpredictably affected by …
View article: Toward Gamma Ray Immune Fibre-Optic Phosphor Thermometry for Nuclear Decommissioning
Toward Gamma Ray Immune Fibre-Optic Phosphor Thermometry for Nuclear Decommissioning Open
Temperature measurement of stored nuclear waste is important for long-term monitoring. Conventional sensors can degrade in ionizing radiation from induced transmutations and their frequent replacement is inconvenient. A thermometer based o…
View article: Imaging Luminescence Thermometry to 750 °C for the Heat Treatment of Common Engineering Alloys and Comparison with Thermal Imaging
Imaging Luminescence Thermometry to 750 °C for the Heat Treatment of Common Engineering Alloys and Comparison with Thermal Imaging Open
Accurate temperature measurements are critical in manufacturing, affecting both product quality and energy consumption. At elevated temperatures, non-contact thermometers are often the only option. However, such instruments require prior k…
View article: Imaging luminescence thermometry to 750 °C for the heat treatment of common engineering alloys and comparison with thermal imaging
Imaging luminescence thermometry to 750 °C for the heat treatment of common engineering alloys and comparison with thermal imaging Open
Data presented in the IJOT paper: Imaging luminescence thermometry to 750 °C for the heat treatment of common engineering alloys and comparison with thermal imaging
View article: Imaging luminescence thermometry to 750 °C for the heat treatment of common engineering alloys and comparison with thermal imaging
Imaging luminescence thermometry to 750 °C for the heat treatment of common engineering alloys and comparison with thermal imaging Open
Data presented in the IJOT paper: Imaging luminescence thermometry to 750 °C for the heat treatment of common engineering alloys and comparison with thermal imaging
View article: Design, construction and traceable calibration of a phosphor-based fibre-optic thermometer from 0 °C to 650 °C
Design, construction and traceable calibration of a phosphor-based fibre-optic thermometer from 0 °C to 650 °C Open
Dataset associated with publication DOI https://doi.org/10.1088/1361-6501/abee53
View article: Design, construction and traceable calibration of a phosphor-based fibre-optic thermometer from 0 °C to 650 °C
Design, construction and traceable calibration of a phosphor-based fibre-optic thermometer from 0 °C to 650 °C Open
Dataset associated with publication DOI https://doi.org/10.1088/1361-6501/abee53
View article: Design, construction and traceable calibration of a phosphor-based fibre-optic thermometer from 0 °C to 650 °C
Design, construction and traceable calibration of a phosphor-based fibre-optic thermometer from 0 °C to 650 °C Open
Measurement traceability, in which there is a documented chain of calibration links from a measurement back to a primary realisation of a unit, is vital for achieving the smallest uncertainty in metrology. A sensor that can provide a trace…
View article: Phosphor thermometry for nuclear decommissioning and waste storage
Phosphor thermometry for nuclear decommissioning and waste storage Open
Reliable surface thermometry of stored nuclear waste containers is essential for both health monitoring and corrosion modelling. In this paper we investigate the feasibility of using phosphor thermometry for long-term temperature monitorin…
View article: Towards an Ultra-High-Speed Combustion Pyrometer
Towards an Ultra-High-Speed Combustion Pyrometer Open
Measuring reliably the correct temperature of a sooty flame in an internal combustion engine is important to optimise its efficiency; however, conventional contact thermometers, such as thermocouples, are not adequate in this context, due …
View article: Thermometry of intermediate level nuclear waste containers in multiple environmental conditions
Thermometry of intermediate level nuclear waste containers in multiple environmental conditions Open
Intermediate level nuclear waste must be stored until it is safe for permanent disposal. Temperature monitoring of waste packages is important to the nuclear decommissioning industry to support management of each package. Phosphor thermome…
View article: Supporting data for "Towards an ultra-high-speed combustion pyrometer" paper
Supporting data for "Towards an ultra-high-speed combustion pyrometer" paper Open
Model and experimental data presented in "Towards an ultra-high-speed combustion pyrometer" paper for the International Journal of Turbomachinery, Propulsion and Power and at the 9th EVI-GTI International Gas Turbine Instrumentati…
View article: Supporting data for "Towards an ultra-high-speed combustion pyrometer" paper
Supporting data for "Towards an ultra-high-speed combustion pyrometer" paper Open
Model and experimental data presented in "Towards an ultra-high-speed combustion pyrometer" paper for the International Journal of Turbomachinery, Propulsion and Power and at the 9th EVI-GTI International Gas Turbine Instrumentati…
View article: Supporting data for "Towards an ultra-high-speed combustion pyrometer" paper
Supporting data for "Towards an ultra-high-speed combustion pyrometer" paper Open
Model and experimental data presented in "Towards an ultra-high-speed combustion pyrometer" paper for the International Journal of Turbomachinery, Propulsion and Power and at the 9th EVI-GTI International Gas Turbine Instrumentati…
View article: Validation of Emission Spectroscopy Gas Temperature Measurements Using a Standard Flame Traceable to the International Temperature Scale of 1990 (ITS-90)
Validation of Emission Spectroscopy Gas Temperature Measurements Using a Standard Flame Traceable to the International Temperature Scale of 1990 (ITS-90) Open
Data underpinning the associated publication (https://doi.org/10.1007/s10765-019-2557-6) on accurate traceable measurement of post-flame temperatures.
View article: Validation of Emission Spectroscopy Gas Temperature Measurements Using a Standard Flame Traceable to the International Temperature Scale of 1990 (ITS-90)
Validation of Emission Spectroscopy Gas Temperature Measurements Using a Standard Flame Traceable to the International Temperature Scale of 1990 (ITS-90) Open
Data underpinning the associated publication (https://doi.org/10.1007/s10765-019-2557-6) on accurate traceable measurement of post-flame temperatures.
View article: Validation of Emission Spectroscopy Gas Temperature Measurements Using a Standard Flame Traceable to the International Temperature Scale of 1990 (ITS-90)
Validation of Emission Spectroscopy Gas Temperature Measurements Using a Standard Flame Traceable to the International Temperature Scale of 1990 (ITS-90) Open
Accurate measurement of post-flame temperatures can significantly improve combustion efficiency and reduce harmful emissions, for example, during the development phase of new internal combustion engines and gas turbine combustors. Non-pert…
View article: Machine learning applied to retrieval of temperature and concentration distributions from infrared emission measurements
Machine learning applied to retrieval of temperature and concentration distributions from infrared emission measurements Open
View article: <i>In situ</i> contactless thermal characterisation and imaging of encapsulated photovoltaic devices using phosphor thermometry
<i>In situ</i> contactless thermal characterisation and imaging of encapsulated photovoltaic devices using phosphor thermometry Open
Accurate temperature measurements of a photovoltaic (PV) device are not always straightforward. Compromises between accuracy and spatial resolution often have to be made to give either quantitative single point measurements or qualitative …
View article: Thermometry of intermediate level waste containers using phosphor thermometry and thermal imaging
Thermometry of intermediate level waste containers using phosphor thermometry and thermal imaging Open
View article: Development of measurement and calibration techniques for dynamic pressures and temperatures (DynPT): background and objectives of the 17IND07 DynPT project in the European Metrology Programme for Innovation and Research (EMPIR)
Development of measurement and calibration techniques for dynamic pressures and temperatures (DynPT): background and objectives of the 17IND07 DynPT project in the European Metrology Programme for Innovation and Research (EMPIR) Open
This project has five specific objectives: To provide traceability for dynamic pressure and temperature through development of measurement standards and validated calibration procedures; To quantify the effects of influencing quantities on…
View article: Thermometry of intermediate level waste containers using phosphor thermometry and thermal imaging
Thermometry of intermediate level waste containers using phosphor thermometry and thermal imaging Open
Intermediate level waste containers are used for the storage of an assortment of radioactive waste. This waste is heat-generating and needs monitoring and so this work was undertaken to determine whether the mean internal container tempera…
View article: The Boltzmann project
The Boltzmann project Open
The International Committee for Weights and Measures (CIPM), at its meeting in October 2017, followed the recommendation of the Consultative Committee for Units (CCU) on the redefinition of the kilogram, ampere, kelvin and mole. For the re…
View article: Re-estimation of argon isotope ratios leading to a revised estimate of the Boltzmann constant
Re-estimation of argon isotope ratios leading to a revised estimate of the Boltzmann constant Open
In 2013, NPL, SUERC and Cranfield University published an estimate for the Boltzmann constant [1] based on a measurement of the limiting low-pressure speed of sound in argon gas. Subsequently, an extensive investigation by Yang et al [2] r…
View article: EMPRESS: A European Project to Enhance Process Control Through Improved Temperature Measurement
EMPRESS: A European Project to Enhance Process Control Through Improved Temperature Measurement Open