Ivan Eltsov
YOU?
Author Swipe
View article: Development of a patient-specific epicardial guide for ventricular tachycardia ablation surgery using high-consistency rubber silicone molding
Development of a patient-specific epicardial guide for ventricular tachycardia ablation surgery using high-consistency rubber silicone molding Open
Background Concomitant epicardial ablation of ventricular tachycardia (VT) remains a clinical challenge in cardiac surgery due to the need for intra-operative mapping. A preoperative patient-tailored epicardial guide could provide an intra…
View article: Impact of Disinfection and Sterilization on 3D-Printing Resin Performance for Surgical Guides in Cardiac Ablation Surgery
Impact of Disinfection and Sterilization on 3D-Printing Resin Performance for Surgical Guides in Cardiac Ablation Surgery Open
Patient-tailored, 3D-printed surgical guides offer significant potential to improve precision and therapeutic efficacy in cardiac ablation surgery. However, reliable post-sterilization material performance presents a critical yet underexpl…
View article: Genetic variants associated with ventricular arrhythmias during ajmaline test in Brugada syndrome
Genetic variants associated with ventricular arrhythmias during ajmaline test in Brugada syndrome Open
Graphical AbstractPathogenic/Likely Pathogenic variants identified in SCN5A and associated with ajmaline-induced ventricular fibrillation following ACMG guidelines
View article: Assessment of activation delay in the right ventricular outflow tract as a potential complementary diagnostic tool for Brugada Syndrome
Assessment of activation delay in the right ventricular outflow tract as a potential complementary diagnostic tool for Brugada Syndrome Open
Aims In patients with Brugada syndrome (BrS), diagnosis relies primarily on the presence of the characteristic type 1 electrocardiographic (ECG) pattern. The aim of this study was to propose an alternative diagnostic method in situations w…
View article: A large footprint catheter toggling between pulsed field and radiofrequency energy: first clinical experience for inappropriate sinus node tachycardia ablation
A large footprint catheter toggling between pulsed field and radiofrequency energy: first clinical experience for inappropriate sinus node tachycardia ablation Open
Background A novel sinus node (SAN) sparing hybrid ablation for inappropriate sinus node tachycardia (IST)/Postural Orthostatic Tachycardia Syndrome (POTS) has been demonstrated to be an effective and safe therapeutic option in patients wi…
View article: Reversible electroporation in atrial flutter: a novel mapping tool
Reversible electroporation in atrial flutter: a novel mapping tool Open
Background Reversible pulsed field ablation (PFREV) can temporarily disrupt cardiomyocyte conduction and may emerge as a novel mapping tool to accurately identify critical isthmuses in tachycardia circuits before creating permanent lesions…
View article: In-vivo endocardial and epicardial mapping of human sinus node: from electrical landmarks to anatomical landmarks
In-vivo endocardial and epicardial mapping of human sinus node: from electrical landmarks to anatomical landmarks Open
Background The human sinoatrial node (SAN) pacemaker is a complex structure located at the right atrium-superior vena cava (SVC) junction. It is intramural with a depth of 1 to 3 mm, and is composed of anastomosing clusters of specialized …
View article: A Hybrid Minimally Invasive Atrial Fibrillation Ablation Procedure Using Unilateral Thoracoscopy and Endocardial Pulsed Field Ablation: An Early Feasibility Study
A Hybrid Minimally Invasive Atrial Fibrillation Ablation Procedure Using Unilateral Thoracoscopy and Endocardial Pulsed Field Ablation: An Early Feasibility Study Open
(1) Objective: To examine the efficiency and efficacy of using endovascular mapping and pulsed field ablation in the setting of a hybrid video-assisted thoracoscopic atrial fibrillation (AF) ablation procedure. (2) Methods: Eleven consecut…
View article: Noninvasive electrocardiographic imaging assessment of conduction system pacing: A novel algorithm to assess intraventricular synchrony
Noninvasive electrocardiographic imaging assessment of conduction system pacing: A novel algorithm to assess intraventricular synchrony Open
View article: Noninvasive electrocardiographic imaging assessment of intraventricular synchrony for conduction system pacing device: a novel algorythm to assess intraventricular synchrony
Noninvasive electrocardiographic imaging assessment of intraventricular synchrony for conduction system pacing device: a novel algorythm to assess intraventricular synchrony Open
Structured Abstract Background Left Bundle branch area pacing has become the procedure of choice for various indications including atrioventricular block and considered to be a physiologic modality of pacing compared to RV apex pacing. Obj…
View article: A large footprint focal catheter toggling between pulsed field and radiofrequency energy: first clinical experience for ventricular tachycardia ablation
A large footprint focal catheter toggling between pulsed field and radiofrequency energy: first clinical experience for ventricular tachycardia ablation Open
View article: 3D mapping challenges in hybrid video-assisted thoracoscopic surgical ablation of Brugada syndrome
3D mapping challenges in hybrid video-assisted thoracoscopic surgical ablation of Brugada syndrome Open
OBJECTIVES Brugada syndrome is a life-threatening disease with an arrhythmogenic substrate located in the epicardium of right ventricle outflow tract. Therefore, the correct region identification is crucial for a successful ablation proced…
View article: Compatibility assessment of a temperature-controlled radiofrequency catheter with a novel electroanatomical mapping system
Compatibility assessment of a temperature-controlled radiofrequency catheter with a novel electroanatomical mapping system Open
Background The novel DiamondTemp ablation system (DTA) and EnSiteX mapping System (EAM) are both CE-Marked and FDA approved medical devices. The DTA has been validated by its manufacturer only in combination with previous version of EnSite…
View article: Hybrid Ablation of Atrial Fibrillation: A Contemporary Overview
Hybrid Ablation of Atrial Fibrillation: A Contemporary Overview Open
Electrical isolation of pulmonary veins (PVI) is the cornerstone of invasive treatment of atrial fibrillation (AF). However, arrhythmia-free survival of a PVI only approach is suboptimal in patients with persistent and long-term persistent…
View article: Universal Method of Compatibility Assessment for Novel Ablation Technologies With Different 3D Navigation Systems
Universal Method of Compatibility Assessment for Novel Ablation Technologies With Different 3D Navigation Systems Open
Background New technologies for ablation procedures are often produced by different companies with no cross-compatibility out of the box. This is not a negligible clinical problem since those separately developed devices are often used tog…
View article: First in human surgical implantation of a leadless pacemaker on the epicardial portion of the right atrial appendage in a patient with a cardiac electronic devices mediated dermatitis
First in human surgical implantation of a leadless pacemaker on the epicardial portion of the right atrial appendage in a patient with a cardiac electronic devices mediated dermatitis Open
A 33-year-old woman with Sick Sinus Node syndrome and persistent atrial fibrillation underwent a Maze IV procedure in order treat atrial fibrillation and concomitant atrial epicardial implantation of a leadless pacemaker to manage her sinu…
View article: Hybrid Surgical Ablation of Recurrent Ventricular Tachycardia in a Patient With High-Risk Brugada Syndrome
Hybrid Surgical Ablation of Recurrent Ventricular Tachycardia in a Patient With High-Risk Brugada Syndrome Open