Jasper Homminga
YOU?
Author Swipe
View article: A Method to Track 3D Knee Kinematics by Multi-Channel 3D-Tracked A-Mode Ultrasound
A Method to Track 3D Knee Kinematics by Multi-Channel 3D-Tracked A-Mode Ultrasound Open
This paper introduces a method for measuring 3D tibiofemoral kinematics using a multi-channel A-mode ultrasound system under dynamic conditions. The proposed system consists of a multi-channel A-mode ultrasound system integrated with a con…
View article: Design of Challenge Based Education: Experiences With Introducing Cbe in the Eciu University
Design of Challenge Based Education: Experiences With Introducing Cbe in the Eciu University Open
With new knowledge developing at an ever higher speed and problems crossing boundaries more and more (both disciplinary as well as nationally), future graduates need to be able to solve multidimensional problems in at least multidisciplina…
View article: Focus on Self-Directed Learning: the Learning and Assessment Philosophy of the University College Twente
Focus on Self-Directed Learning: the Learning and Assessment Philosophy of the University College Twente Open
Background : Developments in modern engineering have led to new materials and production technologies, and as a consequence, new designs that can no longer be attributed to single fields of engineering. Today's breakthrough technologies cr…
View article: Sensitivity of muscle and intervertebral disc force computations to variations in muscle attachment sites
Sensitivity of muscle and intervertebral disc force computations to variations in muscle attachment sites Open
The current paper aims at assessing the sensitivity of muscle and intervertebral disc force computations against potential errors in modeling muscle attachment sites. We perturbed each attachment location in a complete and coherent musculo…
View article: Feasibility of A-mode ultrasound based intraoperative registration in computer-aided orthopedic surgery: A simulation and experimental study
Feasibility of A-mode ultrasound based intraoperative registration in computer-aided orthopedic surgery: A simulation and experimental study Open
The simulation approach provided a well-defined framework for estimating the necessary number of ultrasound registration points and acceptable level of UPLE for a given required level of accuracy for intraoperative registration in CAOS. IC…
View article: A Novel Tibiafemoral Kinematics Measurement System Based on Multi-Channel A-Mode Ultrasound System
A Novel Tibiafemoral Kinematics Measurement System Based on Multi-Channel A-Mode Ultrasound System Open
Improving the accuracy of measuring 6 degree of freedom tibiofemoral kinematics is a crucial step in gait analysis. The skin-marker estimated kinematics is subject to soft tissue artefacts. Fluoroscopic systems have been reported to achiev…
View article: The effect of scoliosis implant design parameters on whole spine mechanical behavior
The effect of scoliosis implant design parameters on whole spine mechanical behavior Open
BackgroundFinite element (FE) models have become a standard pre-clinical tool to study biomechanics of spine and are used to simulate and evaluate different strategies in scoliosis treatment: examine their efficacy as well as the effect of…