Jignesh Amin
YOU?
Author Swipe
View article: Multivariate analysis of inland water quality index in parts of Vapi district, Gujarat, India
Multivariate analysis of inland water quality index in parts of Vapi district, Gujarat, India Open
Water resource management substantially depends on water quality (WQ). Anthropogenic and geogenic pollutants in water system are challenging to identify, transport, and properly dispose of, thus demanding frequent monitoring. Study focuses…
View article: Seismic Vulnerability of RC Frame Building Using Gross and Cracked Section as per Indian Provisions
Seismic Vulnerability of RC Frame Building Using Gross and Cracked Section as per Indian Provisions Open
Fragility analysis essential in the process of predicting the lateral deformation of the structure under earthquake force.Seismic assessment and vulnerability study of a 12-storey RC frame building is carried out.12-storey RC frame is desi…
View article: Performance-based assessment of response reduction factor of RC-elevated water tank considering soil flexibility: a case study
Performance-based assessment of response reduction factor of RC-elevated water tank considering soil flexibility: a case study Open
The seismic design codes/standards of most countries include the nonlinear response of a structure implicitly through a response reduction/modification factor (R). It is the factor by which the actual base shear should be reduced to find t…
View article: Application of DDBD and FBD Methodology for 8-Story RC Frame Using IS 1893 Spectra
Application of DDBD and FBD Methodology for 8-Story RC Frame Using IS 1893 Spectra Open
This study investigates the direct displacement based design (DDBD) and convectional force based design (FBD) approach for 8 storey RC frame building in DDBD methodology the displacement profile is calculated and the given MDOF is converte…
View article: Performance Based Assessment of Seismic Response Factor for SMRF Staging Elevated Water Tank
Performance Based Assessment of Seismic Response Factor for SMRF Staging Elevated Water Tank Open
RC staging water tanks are essential facilities that are expected to remain operational even after sever earthquakes. The seismic design codes/standards of most countries incorporate the nonlinear response of a structure through a ‘seismic…
View article: Numerical simulation of Wind induced mean interference between two tall buildings
Numerical simulation of Wind induced mean interference between two tall buildings Open
The assessment of wind loads on structure is generally carried out using existing codes/standards. The specifications of these codes are based on wind tunnel experiment performed on an isolated building. However, the buildings seldom exist…
View article: Effects of Strengthening Options in Improving the Lateral Responses of RC Frame Building
Effects of Strengthening Options in Improving the Lateral Responses of RC Frame Building Open
During recent past, it was observed that a large number of existing RC frame buildings with irregularities have poor performance or even collapsed during a strong earthquake.Therefore, strengthening of these types of buildings is required …
View article: Evaluation of Shear Wall-RC Frame Interaction of High-Rise Buildings using 2-D model Approach
Evaluation of Shear Wall-RC Frame Interaction of High-Rise Buildings using 2-D model Approach Open
The usefulness of structural walls in the framing of buildings has long been recognized. It is generally preferred to use shear wall in combination with moment resisting frame. In the present study, an effort is also made to investigate th…
View article: Evaluation of response reduction factor and ductility factorfor RC braced frame
Evaluation of response reduction factor and ductility factorfor RC braced frame Open
Response reduction factor is the factor by which the actual base shear force should be reduced, to obtain the design lateral force during design basic earthquake (DBE) shaking. The response reduction factor (R) is basically depends on Over…
View article: Effects of opening in shear walls of 30- storey building
Effects of opening in shear walls of 30- storey building Open
Tall towers and multi-storey buildings have fascinated mankind from the beginning of civilization, their construction being initially for defense and subsequently for ecclesiastical purposes. These tall buildings because of its height, is …