Jin Zeng
YOU?
Author Swipe
View article: Measurement of Enhanced Inversion Factor of InGaAs-Based Well-Island Composite Structure by Photoluminescence Spectra from Dual Facets
Measurement of Enhanced Inversion Factor of InGaAs-Based Well-Island Composite Structure by Photoluminescence Spectra from Dual Facets Open
The inversion factor is an important physical parameter for assessing and revealing the performance of semiconductor lasers, providing insights into the carrier-injected band-filling effect and radiation characteristics. In this paper, the…
View article: The hidden impact of myopia severity on interocular suppression in myopia: a cross-sectional study
The hidden impact of myopia severity on interocular suppression in myopia: a cross-sectional study Open
Objective This study aimed to investigate the association between spherical equivalent (SE) and interocular suppression in myopic adults, addressing the knowledge gap in functional visual impairments beyond structural changes. Methods This…
View article: Increasing myopic refraction reduces random dot stereopsis in Chinese myopic patients: a cross-sectional study
Increasing myopic refraction reduces random dot stereopsis in Chinese myopic patients: a cross-sectional study Open
View article: Thinning of maximum ciliary body thickness: a potential early indicator for pseudophakic malignant glaucoma in primary angle closure glaucoma
Thinning of maximum ciliary body thickness: a potential early indicator for pseudophakic malignant glaucoma in primary angle closure glaucoma Open
Objective Pseudophakic malignant glaucoma (PMG) is an uncommon but severe postoperative complication that poses a significant threat to vision. Early detection of PMG in patients with primary angle closure glaucoma (PACG) is imperative for…
View article: A novel corneal indentation device for comparison of corneal tangent modulus before and after FS-LASIK in vivo
A novel corneal indentation device for comparison of corneal tangent modulus before and after FS-LASIK in vivo Open
View article: Correlations of anterior and posterior corneal parameters in Chinese myopic patients: a retrospective multicenter study
Correlations of anterior and posterior corneal parameters in Chinese myopic patients: a retrospective multicenter study Open
The anterior-posterior correlations of corneal curvature, astigmatism, eccentricity, and asphericity are affected by the severity of myopia and some other corneal parameters.
View article: Reduction in maximum ciliary body thickness could be a pre-existing predictor for pseudophakic malignant glaucoma
Reduction in maximum ciliary body thickness could be a pre-existing predictor for pseudophakic malignant glaucoma Open
Objective: Malignant glaucoma is a rare and vision threatening form of glaucoma occurring in certain postoperative patients. It presents difficult diagnostic challenge. Dentification of morphometric indicators enables to predict the develo…
View article: A Novel Corneal Indentation Device for Comparison of Corneal Tangent Modulus before and after FS-LASIK in vivo
A Novel Corneal Indentation Device for Comparison of Corneal Tangent Modulus before and after FS-LASIK in vivo Open
Background Corneal refractive laser surgery is widely used to correct myopia and astigmatism due to its safety and effectiveness. However, postoperative changes in corneal biomechanics, such as corneal ectasia, can occur, necessitating a d…
View article: Research progress in mechanized and intelligentized pollination technologies for fruit and vegetable crops
Research progress in mechanized and intelligentized pollination technologies for fruit and vegetable crops Open
View article: Virtual Reality Assessment Reveals Myopic Regression After ICL Implantation in High Myopia
Virtual Reality Assessment Reveals Myopic Regression After ICL Implantation in High Myopia Open
Purpose: To investigate the correlative factors of vision regression after Implantable Collamer Lens (ICL) surgery from the perspective of binocular vision and to develop a predictive model for the refractive change over the long term. Met…
View article: Correlations of anterior and posterior corneal parameters in Chinese myopic patients
Correlations of anterior and posterior corneal parameters in Chinese myopic patients Open
Background Whether the correlations between anterior and posterior corneal parameters vary according to different conditions is unknown. Methods A total of 8365 myopic eyes having refractive surgery between 2017 and 2019 from multiple opht…
View article: Targeting displacement as an indicator of binocular fixation in normal Chinese adults
Targeting displacement as an indicator of binocular fixation in normal Chinese adults Open
Purpose The stability of fixation is crucial for the development of visual function. In this study, we quantify the deviation of visual target during fixational and saccadic tasks using eye-tracking technology, reflecting the control abili…
View article: A Simple Optical Aerosol Sensing Method of Sauter Mean Diameter for Particulate Matter Monitoring
A Simple Optical Aerosol Sensing Method of Sauter Mean Diameter for Particulate Matter Monitoring Open
Mass concentration is a commonly used but insufficient metric to evaluate the particulate matter (PM) exposure hazard. Recent studies have declared that small particles have more serious impacts on human health than big particles given the…
View article: High HDL-C and high LDL-C are risk factors of pterygium in a population-based cross-sectional study in Southern China: the Dongguan Eye Study
High HDL-C and high LDL-C are risk factors of pterygium in a population-based cross-sectional study in Southern China: the Dongguan Eye Study Open
Objectives To investigate the relationship between serum lipids and pterygium in a large-scale rural population aged 40 years or older from Southern China. Study design The Dongguan Eye Study was a cross-sectional population-based study fr…
View article: [Corrigendum] MicroRNA‑10b promotes migration and invasion through KLF4 and HOXD10 in human bladder cancer
[Corrigendum] MicroRNA‑10b promotes migration and invasion through KLF4 and HOXD10 in human bladder cancer Open
Following the publication of the above paper, an interested reader drew to the authors' attention that, in Fig. 2 on p. 1835, which was designed to show how miR‑10b promotes the migration and invasion of human bladder cancer cell lines …
View article: Comparison of Ex-PRESS implantation versus trabeculectomy combined with phacoemulsification in primary open-angle glaucoma: a retrospective in vivo confocal microscopy study
Comparison of Ex-PRESS implantation versus trabeculectomy combined with phacoemulsification in primary open-angle glaucoma: a retrospective in vivo confocal microscopy study Open
View article: Environmental Factors Assisted the Evaluation of Entropy Water Quality Indices With Efficient Machine Learning Technique
Environmental Factors Assisted the Evaluation of Entropy Water Quality Indices With Efficient Machine Learning Technique Open
Water is an indispensable resource for human production and life. The evaluation of water quality by scientific method that provides sufficient support for the regeneration and recycling utilization of water resources. At present, water qu…
View article: Usefulness of Machine Learning for Identification of Referable Diabetic Retinopathy in a Large-Scale Population-Based Study
Usefulness of Machine Learning for Identification of Referable Diabetic Retinopathy in a Large-Scale Population-Based Study Open
Purpose: To development and validation of machine learning-based classifiers based on simple non-ocular metrics for detecting referable diabetic retinopathy (RDR) in a large-scale Chinese population–based survey. Methods: The 1,418 patient…
View article: On-line high-accuracy particulate matter monitoring technology using multi-channel scattering signals
On-line high-accuracy particulate matter monitoring technology using multi-channel scattering signals Open
Particulate matter has adverse effects on the environment and human health, thus emission monitoring of particulate matter is essential for environment and human health protection. Optical methods are popular for on-line particulate matter…
View article: Three-Random-Point Marking Method for Toric Intraocular Lens Alignment Using the iTrace Aberrometer
Three-Random-Point Marking Method for Toric Intraocular Lens Alignment Using the iTrace Aberrometer Open
Purpose. To evaluate the clinical outcome of the three-random-point (TRP) marking method for toric intraocular lens (IOL) alignment using the iTrace aberrometer (Tracey Technologies Corp., Houston, TX). Setting. Department of Ophthalmology…
View article: Binocular integration and stereopsis in children with television torticollis
Binocular integration and stereopsis in children with television torticollis Open
Background To observe the characteristics of binocular integration and stereopsis in children with television torticollis. Methods A retrospective study was carried out, where data were collected from 25 children with television torticolli…
View article: Three-wavelength optical sensor for measuring distributed mass concentrations of aerosols from stationary sources
Three-wavelength optical sensor for measuring distributed mass concentrations of aerosols from stationary sources Open
Stationary source emissions of key industries, such as thermal power plants, have become the central consideration in environmental protection programs. Existing photoelectric sensors at stationary sources usually use a single wavelength l…
View article: Microvascular changes in macula and optic nerve head after femtosecond laser-assisted LASIK: an optical coherence tomography angiography study
Microvascular changes in macula and optic nerve head after femtosecond laser-assisted LASIK: an optical coherence tomography angiography study Open
View article: Correction: MiR-1 downregulation correlates with poor survival in clear cell renal cell carcinoma where it interferes with cell cycle regulation and metastasis
Correction: MiR-1 downregulation correlates with poor survival in clear cell renal cell carcinoma where it interferes with cell cycle regulation and metastasis Open
[This corrects the article DOI: 10.18632/oncotarget.3915.].
View article: Intraocular Pressure in General and Diabetic Populations From Southern China: the Dongguan Eye Study
Intraocular Pressure in General and Diabetic Populations From Southern China: the Dongguan Eye Study Open
The present study identifies risk factors for elevated IOP in general and diabetic populations. Younger age and lower HDL-C, as well as higher BP, LDL-C, and CCT were significant factors contributing to higher IOP, especially in the female…
View article: Vision-related quality of life and depression in rhegmatogenous retinal detachment patients
Vision-related quality of life and depression in rhegmatogenous retinal detachment patients Open
The aim of this cross-sectional study is to evaluate vision-related quality of life (VRQoL) and depression in patients with rhegmatogenous retinal detachment (RRD). The VRQoL and depression were evaluated in 58 patients with unilateral RRD…
View article: Femtosecond laser-assisted removal of an intracorneal chestnut, a case report
Femtosecond laser-assisted removal of an intracorneal chestnut, a case report Open
View article: Comparison of perceptual eye positions among patients with different degrees of anisometropia
Comparison of perceptual eye positions among patients with different degrees of anisometropia Open
The aim of this study is to compare the perceptual eye positions (PEPs) among patients with different degrees of anisometropia.A total of 157 patients were recruited into this retrospective study. A detailed ophthalmic examination was cond…
View article: Predictive role of corneal Q-value differences between nasal–temporal and superior–inferior quadrants in orthokeratology lens decentration
Predictive role of corneal Q-value differences between nasal–temporal and superior–inferior quadrants in orthokeratology lens decentration Open
The sum of pretreatment corneal Q-value differences between nasal-temporal and superior-inferior quadrants is a convenient and reliable predictor for orthokeratology lens decentration.
View article: Comparation of effectiveness of silicone hydrogel contact lens and hydrogel contact lens in patients after LASEK.
Comparation of effectiveness of silicone hydrogel contact lens and hydrogel contact lens in patients after LASEK. Open
Patients with LASEK using silicon hydrogel contact lenses had less discomfort and shorter corneal epithelial healing time compared with those using hydrogel contact lenses, suggesting that silicon hydrogel contact lenses may be considered …