Kazuo Ichikawa
YOU?
Author Swipe
View article: Lens shape confirmed in light adjustable lens: A report of two cases
Lens shape confirmed in light adjustable lens: A report of two cases Open
The findings in Case 1 highlighted a change in shape while maintaining a spherical lens shape, while in Case 2, the change in asymmetric shape may have occurred to correct astigmatism on the back of the LAL. Taken together, these findings …
View article: Evaluation of the Insertion Depth of the iStent Inject W and Its Association with Surgical Outcomes Using Automated Gonioscopy
Evaluation of the Insertion Depth of the iStent Inject W and Its Association with Surgical Outcomes Using Automated Gonioscopy Open
Background/Objectives: The iStent is a trabecular micro-bypass device used in glaucoma management. Its depth has been evaluated using anterior segment optical coherence tomography; however, no reports have assessed it using gonioscopy. We …
View article: Clinical performance of a hydrophobic acrylic toric intraocular lens with a double C-loop haptics in Japanese patients
Clinical performance of a hydrophobic acrylic toric intraocular lens with a double C-loop haptics in Japanese patients Open
Purpose To evaluate the clinical performance of a hydrophobic acrylic toric intraocular lens (IOL) with double C-loop haptics in a Japanese population with cataracts. Study design Prospective Methods The PODEYE TORIC IOL (POD T 49P) was im…
View article: Study on Factors Affecting Toric Intraocular Lens Rotation Using Intraoperative OCT—Factors Influencing IOL Deployment and Proximity to Posterior Capsule After Insertion
Study on Factors Affecting Toric Intraocular Lens Rotation Using Intraoperative OCT—Factors Influencing IOL Deployment and Proximity to Posterior Capsule After Insertion Open
Background/Objectives: Cataract surgery often reveals preexisting corneal astigmatism, which can be corrected using a toric intraocular lens (T-IOL). However, postoperative T-IOL rotation may compromise correction. We investigated T-IOL ro…
View article: Comparison of angle-closure detection between automated gonioscopy and anterior-segment optical coherence tomography
Comparison of angle-closure detection between automated gonioscopy and anterior-segment optical coherence tomography Open
Purpose To investigate the concordance between angle-closure assessments based on GS-1 gonioscope images and those obtained with anterior-segment optical coherence tomography. Study design Retrospective clinical study . Methods We included…
View article: Comparison of Adhesion of Immortalized Human Iris-Derived Cells and Fibronectin on Phakic Intraocular Lenses Made of Different Polymer Base Materials
Comparison of Adhesion of Immortalized Human Iris-Derived Cells and Fibronectin on Phakic Intraocular Lenses Made of Different Polymer Base Materials Open
Background and Objectives: Posterior chamber phakic implantable contact lenses (Phakic-ICL) are widely used for refractive correction due to their efficacy and safety, including minimal corneal endothelial cell loss. The Collamer-based EVO…
View article: Evaluation of visual function within the central 10 degrees using IMOvifa™ 24plus (1-2)
Evaluation of visual function within the central 10 degrees using IMOvifa™ 24plus (1-2) Open
Purpose The IMOvifa™ perimeter with a 24plus (1-2) testing mode has additional measurement points within the central 10 degrees, which may help evaluate the visual field within this area. Here, we comparatively evaluated the IMOvifa™ 24plu…
View article: Comparison of IMO vifa24plus(1-2) and Humphrey Field Analyzer 24-2
Comparison of IMO vifa24plus(1-2) and Humphrey Field Analyzer 24-2 Open
The IMO vifa demonstrates a very high correlation with HFA and allows for a shorter examination time. Fixation errors are significantly improved compared to HFA, while there is no significant difference in false positives or false negative…
View article: A Multicenter Study on Clinical Outcomes of Simultaneous Implantable Collamer Lens Removal and Phacoemulsification with Intraocular Lens Implantation in Eyes Developing Cataract
A Multicenter Study on Clinical Outcomes of Simultaneous Implantable Collamer Lens Removal and Phacoemulsification with Intraocular Lens Implantation in Eyes Developing Cataract Open
Our multicenter study showed that simultaneous ICL removal and phacoemulsification with IOL implantation is a safe, effective, and predictable procedure, with no significant complications, making it a feasible option for ICL-implanted eyes…
View article: Comparison of accuracy and axial length acquisition success rate by three types of swept-source OCT-based biometers
Comparison of accuracy and axial length acquisition success rate by three types of swept-source OCT-based biometers Open
Purpose: To compare three biometers equipped with swept-source optical coherence tomography (OCT), including ARGOS (OCTB1), IOLMaster 700 (OCTB2), and Anterion (AS-OCTB). The primary aim was to assess the axial length (AL) acquisition succ…
View article: Comparison of Phacoemulsification and Aspiration Parameters in Cataract Surgery: Metal Tip vs. Hybrid Tip
Comparison of Phacoemulsification and Aspiration Parameters in Cataract Surgery: Metal Tip vs. Hybrid Tip Open
Various tips are available for phacoemulsification in cataract surgery. Evidence-based data can inform ophthalmologists, especially inexperienced ones, on tip selection. We retrospectively evaluated the energy efficiency and other paramete…
View article: Near Add Power of Glaucoma Patients with Early Presbyopia
Near Add Power of Glaucoma Patients with Early Presbyopia Open
Purpose: Glaucoma medication may accelerate the progression of presbyopia. The aim of this study was to compare presbyopia between controls and patients with glaucoma in their 40s. Methods: This was a cross-sectional study of bilateral pha…
View article: Effect of Intraocular Lens Power Calculation Formula Optimization in the Sum-of-Segments Optical Biometer
Effect of Intraocular Lens Power Calculation Formula Optimization in the Sum-of-Segments Optical Biometer Open
In long and short eyes, the current study revealed that optimization of the SRK/T and Barrett formula constants for the SRI biometer was beneficial to achieve accurate refractive outcomes after cataract surgery.
View article: Retraction Note: Posterior chamber phakic intraocular lens implantation after laser in situ keratomileusis
Retraction Note: Posterior chamber phakic intraocular lens implantation after laser in situ keratomileusis Open
View article: Accuracy of new intraocular lens power calculation formula for short and long eyes using segmental refractive indices
Accuracy of new intraocular lens power calculation formula for short and long eyes using segmental refractive indices Open
Purpose: To evaluate the accuracy of a new intraocular lens power calculation formula using segmental refractive index-based axial length (AL). Setting: Chukyo Eye Clinic, Nagoya, Japan. Design: Retrospective observational study. Methods: …
View article: Accuracy of the Majority Voting Method with Multiple IOL Power Formulae
Accuracy of the Majority Voting Method with Multiple IOL Power Formulae Open
The proposed majority decision algorithm incorporating IA and two IOL frequency formulas was effective in reducing postoperative refractive error. IA was particularly beneficial for eyes with long axial length. These findings suggest the a…
View article: Gender-based differences in the job titles and lifestyles in the cataract and refractive surgery society in Japan
Gender-based differences in the job titles and lifestyles in the cataract and refractive surgery society in Japan Open
To investigate sex differences in the titles and lifestyles of Japanese ophthalmologists, we evaluated work places and private lives. Retrospective cross-sectional study. The study included 1721 members (1344 males and 377 females) of the …
View article: Comparison of INTREPID® balanced and hybrid tips on anterior capsule rupture in ex vivo porcine eyes
Comparison of INTREPID® balanced and hybrid tips on anterior capsule rupture in ex vivo porcine eyes Open
Phacoemulsification has emerged as the global standard for cataract surgery, and various novel methods, tools, and agents have promoted surgical efficiency and reduced complications. Conventionally, the phaco tip, which cleaves and aspirat…
View article: Color visual field measurements for detecting glaucoma
Color visual field measurements for detecting glaucoma Open
This study evaluated the difference between glaucoma and normal eyes using a color visual field (CVF) test. Thirty-seven eyes of 37 normal subjects (mean age 56.6±12.0 years) and 39 eyes of 39 patients with glaucoma (mean age 57.1±11.3 yea…
View article: Flexural and Cell Adhesion Characteristic of Phakic Implantable Lenses
Flexural and Cell Adhesion Characteristic of Phakic Implantable Lenses Open
Background and Objectives: In this study, we aimed to compare the physical properties of hole-implantable collamer lenses (H-ICLs) and implantable phakic contact lenses (IPCLs) and investigate their flexural and cell adhesion characteristi…
View article: Comparison of the efficacy and invasiveness of manual and automated gonioscopy
Comparison of the efficacy and invasiveness of manual and automated gonioscopy Open
Purpose To compare the efficacy and invasiveness of manual gonioscopy and automated 360-degree gonioscopy. Method Manual and automated gonioscopy were performed on 70 patients with glaucoma. Manual gonioscopy was performed by a glaucoma sp…
View article: Clinical Performance of a Hydrophobic Acrylic Diffractive Trifocal Intraocular Lens in a Japanese Population
Clinical Performance of a Hydrophobic Acrylic Diffractive Trifocal Intraocular Lens in a Japanese Population Open
View article: A Nationwide Multicenter Study on 1-Year Outcomes of Posterior Chamber Phakic Intraocular Lens Implantation for Low Myopia
A Nationwide Multicenter Study on 1-Year Outcomes of Posterior Chamber Phakic Intraocular Lens Implantation for Low Myopia Open
Purpose To assess the nationwide multicenter outcomes of posterior chamber phakic intraocular lens implantation with a central hole (EVO-ICL, STAAR Surgical) for patients with low myopia. Methods This multicenter study comprised 172 eyes o…
View article: RETRACTED ARTICLE: Posterior chamber phakic intraocular lens implantation after laser in situ keratomileusis
RETRACTED ARTICLE: Posterior chamber phakic intraocular lens implantation after laser in situ keratomileusis Open
View article: Multicenter clinical outcomes of hole implantable collamer lens implantation in middle-aged patients
Multicenter clinical outcomes of hole implantable collamer lens implantation in middle-aged patients Open
View article: Multicenter survey on implantable collamer lens dislocation
Multicenter survey on implantable collamer lens dislocation Open
This study aimed to investigate the incidence, patient background, and postoperative prognosis of implantable collamer lens (ICL) dislocation. We retrospectively reviewed all cases of ICL dislocation at four major refractive surgery center…
View article: Treatment of old submacular hemorrhage by subretinal endoscopic surgery and intraoperative subretinal endoscopic findings
Treatment of old submacular hemorrhage by subretinal endoscopic surgery and intraoperative subretinal endoscopic findings Open
View article: Rotational stability and clinical outcomes of a new one piece toric intraocular lens with anchor-wing haptics
Rotational stability and clinical outcomes of a new one piece toric intraocular lens with anchor-wing haptics Open
View article: Refractive Errors after Cataract Surgery Using Total Keratometry in Post-LASIK Eyes
Refractive Errors after Cataract Surgery Using Total Keratometry in Post-LASIK Eyes Open
【目的】LASIK後眼に対しTotal Keratometry(TK)を用いたLASIK用IOL度数計算式と従来式による予測屈折誤差を比較し、TKの有用性を評価する。
View article: Age-related changes of color visual acuity in normal eyes
Age-related changes of color visual acuity in normal eyes Open
Purpose To evaluate the age-related change in color visual acuity (CVA) in normal eyes. Methods In total, 162 normal eyes (162 subjects, women: 52, men: 110, age range: 15–68 years) with best-corrected visual acuity (BCVA) ≥20/13 were enro…