Kumi Y. Inoue
YOU?
Author Swipe
View article: Electrochemical Bioimaging Using Bipolar Microelectrode Arrays
Electrochemical Bioimaging Using Bipolar Microelectrode Arrays Open
View article: Detection of C‐Reactive Protein by Electrochemiluminescence‐Based Droplet‐Free Digital Immunoassay with Tyramide Signal Amplification
Detection of C‐Reactive Protein by Electrochemiluminescence‐Based Droplet‐Free Digital Immunoassay with Tyramide Signal Amplification Open
C‐reactive protein (CRP) is a widely used biomarker for monitoring inflammatory processes and assessing disease progression in various conditions, including cardiovascular diseases, infections, and autoimmune disorders. In this study, a si…
View article: Bipolar electrochemical sensor with perylene diimide-based cathodic luminophore for dopamine detection and imaging
Bipolar electrochemical sensor with perylene diimide-based cathodic luminophore for dopamine detection and imaging Open
Bipolar electrochemical microscopy (BEM), which visualizes the concentration distribution of molecular species in biological systems by electrochemiluminescence (ECL), is expected to be applied to the high-spatiotemporal-resolution imaging…
View article: ACCS 2023 Participation Report and ACCS 2024 Information from Japan Association of Chemical Sensors
ACCS 2023 Participation Report and ACCS 2024 Information from Japan Association of Chemical Sensors Open
View article: Enhancement of Electrochemiluminescence by Au Paste Electrode for Bipolar Electroanalysis
Enhancement of Electrochemiluminescence by Au Paste Electrode for Bipolar Electroanalysis Open
Carbon paste electrodes (CPEs) are widely used because of their malleability and ease of modification of functional molecules. This study introduces the application of Au paste electrodes (AuPEs) as a method for amplifying electrochemilumi…
View article: Relationship between Plasma Lipopolysaccharide Concentration and Health Status in Healthy Subjects and Patients with Abnormal Glucose Metabolism in Japan: A Preliminary Cross-Sectional Study
Relationship between Plasma Lipopolysaccharide Concentration and Health Status in Healthy Subjects and Patients with Abnormal Glucose Metabolism in Japan: A Preliminary Cross-Sectional Study Open
Lipopolysaccharides are components of Gram-negative bacteria. The relationship between blood lipopolysaccharide levels and health status has mainly been investigated in Europe, and there is a lack of information about Asia, particularly Ja…
View article: C-reactive Protein Detection Using an Ion-sensitive Field-effect Transistor (ISFET)-based Aptasensor with a Chemically Modified Gate Surface for Improved Sensitivity
C-reactive Protein Detection Using an Ion-sensitive Field-effect Transistor (ISFET)-based Aptasensor with a Chemically Modified Gate Surface for Improved Sensitivity Open
View article: Effect of Valinomycin on the Respiration Activity of Zebrafish Embryos Using a Large-Scale-Integration-based Multiple Amperometric Biosensor
Effect of Valinomycin on the Respiration Activity of Zebrafish Embryos Using a Large-Scale-Integration-based Multiple Amperometric Biosensor Open
View article: Intestinal and fecal pH in human health
Intestinal and fecal pH in human health Open
Gut microbiota has been reported to be closely related to host energy metabolism and immunity, and thus influence the development and progression of various human diseases. To date, the gut microbial metabolites such as short-chain fatty a…
View article: Energy-harvesting and mass sensor performances of magnetostrictive cobalt ferrite-spattered Fe–Co alloy plate
Energy-harvesting and mass sensor performances of magnetostrictive cobalt ferrite-spattered Fe–Co alloy plate Open
View article: Droplet-free digital immunoassay based on electrochemiluminescence
Droplet-free digital immunoassay based on electrochemiluminescence Open
Here, we report a droplet-free digital immunoassay for goat immunoglobulin G (IgG) based on electrochemiluminescence (ECL) for simplified digital immunoassay. Digital enzyme-linked immunosorbent assay (ELISA) enabled ultrasensitive detecti…
View article: Highly Sensitive Electrochemical Endotoxin Sensor Based on Redox Cycling Using an Interdigitated Array Electrode Device
Highly Sensitive Electrochemical Endotoxin Sensor Based on Redox Cycling Using an Interdigitated Array Electrode Device Open
The Limulus amebocyte lysate (LAL) reaction-based assay, the most commonly used endotoxin detection method, requires a skilled technician. In this study, to develop an easy-to-use and highly sensitive endotoxin sensor, we created an electr…
View article: Bipolar Electrochemical Sensor with Perylene Diimide-Based Cathodic Luminophore for Dopamine Detection and Imaging
Bipolar Electrochemical Sensor with Perylene Diimide-Based Cathodic Luminophore for Dopamine Detection and Imaging Open
View article: Batteryless wireless magnetostrictive Fe30Co70/Ni clad plate for human coronavirus 229E detection
Batteryless wireless magnetostrictive Fe30Co70/Ni clad plate for human coronavirus 229E detection Open
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been garnered increasing for its rapid worldwide spread. Each country had implemented city-wide lockdowns and immigration regulations to prevent the spread of the infection, …
View article: Electrochemiluminescence Imaging Based on Bipolar Electrochemistry Using Commercially Available Anisotropic Conductive Films
Electrochemiluminescence Imaging Based on Bipolar Electrochemistry Using Commercially Available Anisotropic Conductive Films Open
View article: Electrochemical Substrates and Systems for Enzyme-Based Bioassays
Electrochemical Substrates and Systems for Enzyme-Based Bioassays Open
バイオ分析において基質が果たす役割は大きい.例えば,イムノアッセイでは酵素標識された抗体が用いられ,さらに酵素に特異的に反応する基質を添加して,酵素生成物を検出することで目的の測定物を定量できる.健康診断における検体サンプルや培養細胞における抗原の検出では,酵素を用いた免疫染色法が幅広く用いられており,基質からの酵素生成物の着色により可視化されている.多くの場合は,生成物の光学特性を生かし,着色したり,吸光度測定したりするが,装置の簡便さや優れた定量性を生かし,電気化学計測…
View article: Droplet-Free Digital Immunoassay Based on Electrochemiluminescence
Droplet-Free Digital Immunoassay Based on Electrochemiluminescence Open
View article: Droplet-Free Digital Immunoassay Based on Electrochemiluminescence
Droplet-Free Digital Immunoassay Based on Electrochemiluminescence Open
View article: Droplet-Free Digital Immunoassay Based on Electrochemiluminescence
Droplet-Free Digital Immunoassay Based on Electrochemiluminescence Open
View article: Droplet-Free Digital Immunoassay Based on Electrochemiluminescence
Droplet-Free Digital Immunoassay Based on Electrochemiluminescence Open
View article: Thermally‐Drawn Multi‐Electrode Fibers for Bipolar Electrochemistry and Magnified Electrochemical Imaging
Thermally‐Drawn Multi‐Electrode Fibers for Bipolar Electrochemistry and Magnified Electrochemical Imaging Open
Imaging systems using closed bipolar electrode (cBPE) arrays and electrochemiluminescence (ECL) have attracted great attention in recent years as a 2D imaging platform with high spatiotemporal resolution. However, the fabrication technique…
View article: Simultaneous Monitoring of Oxygen Consumption and Movement of Zebrafish Embryos Based on an LSI-based Electrochemical Multiple-biosensor
Simultaneous Monitoring of Oxygen Consumption and Movement of Zebrafish Embryos Based on an LSI-based Electrochemical Multiple-biosensor Open
We have estimated the effect of a chemical reagent based on the oxygen consumption and the motion of zebrafish embryos by using an LSI-based amperometric sensor array device (Bio-LSI). Bio-LSI with 400 gold microelectrodes in a 6 mm × 6 mm…
View article: Announcements
Announcements Open
View article: Detection and 2D Imaging of Dopamine Distribution Using a Closed Bipolar Electrode System by Applying a Cathodic Luminophore
Detection and 2D Imaging of Dopamine Distribution Using a Closed Bipolar Electrode System by Applying a Cathodic Luminophore Open
A 2D imaging system using closed bipolar electrodes (cBPEs) and electrochemiluminescence (ECL) is expected to realize high spatio‐temporal resolution imaging. However, imaging of the distributions of molecules that cause an oxidation react…
View article: Bipolar Electrode‐based Electrochromic Devices for Analytical Applications – A Review
Bipolar Electrode‐based Electrochromic Devices for Analytical Applications – A Review Open
Bipolar electrode‐based (BPE‐based) electrochromic devices have garnered increasing attention in the past decade. These BPE‐based electrochromic devices have been used for analytical health monitoring, point‐of‐care (POC) diagnostics, and …
View article: Electrochemical Sensor to Detect Proteinuria Using Peptidases and Glutamate Oxidase Jointly Immobilized on a Prussian Blue-modified Electrode
Electrochemical Sensor to Detect Proteinuria Using Peptidases and Glutamate Oxidase Jointly Immobilized on a Prussian Blue-modified Electrode Open
In this work, we report a simple electrochemical sensor that detects proteinuria upon immersion into a sample. We immobilized peptidases in conjunction with glutamate oxidase (GluOx) on a Prussian blue-modified glassy carbon (PB-GC) electr…
View article: Biosensors and biosensing in the era of digital health
Biosensors and biosensing in the era of digital health Open
View article: Current challenges and future perspectives on nanoscale analysis for electrochemistry
Current challenges and future perspectives on nanoscale analysis for electrochemistry Open
View article: Recent Advances in Electrochemiluminescence-Based Systems for Mammalian Cell Analysis
Recent Advances in Electrochemiluminescence-Based Systems for Mammalian Cell Analysis Open
Mammalian cell analysis is essential in the context of both fundamental studies and clinical applications. Among the various techniques available for cell analysis, electrochemiluminescence (ECL) has attracted significant attention due to …
View article: Electrochemical Detection of Kallikrein Using a <i>p</i>-Methoxyaniline-conjugated Tripeptide towards Simple Diagnosis of Primary Aldosteronism
Electrochemical Detection of Kallikrein Using a <i>p</i>-Methoxyaniline-conjugated Tripeptide towards Simple Diagnosis of Primary Aldosteronism Open
Kallikrein is a serine protease which is involved in blood pressure regulation and is overexpressed in primary aldosteronism. We hypothesized that quick quantification of this enzyme could represen...