E. Calvo
YOU?
Author Swipe
View article: Cosmic Ray Measurements Using Charge and Light Readout in a Pixelated Liquid Argon Time Projection Chamber
Cosmic Ray Measurements Using Charge and Light Readout in a Pixelated Liquid Argon Time Projection Chamber Open
Liquid argon time projection chambers have emerged as a competitive technology for detecting solar neutrinos. The SoLAr collaboration was formed to explore argon detectors with pixelated light and charge readout, aiming for high detection …
View article: Muon tracking in a LiquidO opaque scintillator detector
Muon tracking in a LiquidO opaque scintillator detector Open
LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in …
View article: The ILD Detector: A Versatile Detector for an Electron-Positron Collider at Energies up to 1 TeV
The ILD Detector: A Versatile Detector for an Electron-Positron Collider at Energies up to 1 TeV Open
The International Large Detector, ILD, is a detector concept for an experiment at a future high energy lepton collider. The detector has been optimised for precision physics in a range of energies from 90~GeV to about 1~TeV. ILD features a…
View article: Time-resolved mitochondrial screen identifies regulatory components of oxidative metabolism
Time-resolved mitochondrial screen identifies regulatory components of oxidative metabolism Open
View article: The Stochastic Light Confinement of LiquidO
The Stochastic Light Confinement of LiquidO Open
Light-based detectors have been widely used in fundamental research and industry since their inception in the 1930s. The energy particles deposit in these detectors is converted to optical signals via the Cherenkov and scintillation mechan…
View article: Measurement of the absolute efficiency of the X-ARAPUCA photon detector for the DUNE Far Detector 1
Measurement of the absolute efficiency of the X-ARAPUCA photon detector for the DUNE Far Detector 1 Open
View article: Time-resolved mitochondrial-focused screening identifies regulatory components of oxidative metabolism
Time-resolved mitochondrial-focused screening identifies regulatory components of oxidative metabolism Open
SUMMARY Defects in mitochondrial oxidative metabolism contribute to various genetic inherited disorders, termed mitochondrial diseases, with limited treatment options. Given the lack of functional annotation for numerous mitochondrial prot…
View article: Characterization of a radiation detector based on opaque water-based liquid scintillator
Characterization of a radiation detector based on opaque water-based liquid scintillator Open
We present the characterization of a novel radiation detector based on an opaque water-based liquid scintillator. Opaque scintillators, also known as LiquidO, are made to be highly scattering, such that the scintillation light is effective…
View article: Measurement of the photon detection efficiency of Hamamatsu VUV4 SiPMS at cryogenic temperature
Measurement of the photon detection efficiency of Hamamatsu VUV4 SiPMS at cryogenic temperature Open
View article: Cryogenic characterization of Hamamatsu HWB MPPCs for the DUNE photon detection system
Cryogenic characterization of Hamamatsu HWB MPPCs for the DUNE photon detection system Open
The Deep Underground Neutrino Experiment (DUNE) is a next generation experiment aimed to study neutrino oscillation. Its long-baseline configuration will exploit a Near Detector (ND) and a Far Detector (FD) located at a distance of ∼1300 k…
View article: Probing Earth's Missing Potassium using the Unique Antimatter Signature of Geoneutrinos
Probing Earth's Missing Potassium using the Unique Antimatter Signature of Geoneutrinos Open
The formation of the Earth remains an epoch with mysterious puzzles extending to our still incomplete understanding of the planet's potential origin and bulk composition. Direct confirmation of the Earth's internal heat engine was accompli…
View article: Validation of electrodeposited 241Am alpha-particle sources for use in liquified gas detectors at cryogenic temperatures
Validation of electrodeposited 241Am alpha-particle sources for use in liquified gas detectors at cryogenic temperatures Open
View article: Description and stability of a RPC-based calorimeter in electromagnetic and hadronic shower environments
Description and stability of a RPC-based calorimeter in electromagnetic and hadronic shower environments Open
The CALICE Semi-Digital Hadron Calorimeter technological prototype completed in 2011 is a sampling calorimeter using Glass Resistive Plate Chamber (GRPC) detectors as the active medium. This technology is one of the two options proposed fo…
View article: The Analytical Method algorithm for trigger primitives generation at the LHC Drift Tubes detector
The Analytical Method algorithm for trigger primitives generation at the LHC Drift Tubes detector Open
View article: The Double Chooz antineutrino detectors
The Double Chooz antineutrino detectors Open
View article: Energy reconstruction of hadronic showers at the CERN PS and SPS using the Semi-Digital Hadronic Calorimeter
Energy reconstruction of hadronic showers at the CERN PS and SPS using the Semi-Digital Hadronic Calorimeter Open
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) is the first technological prototype in a family of high-granularity calorimeters developed by the CALICE Collaboration to equip the experiments of future lepton colliders. The SDHCAL i…
View article: Cell tension controlling pathways and nutrient availability regulate plasma membrane ATP synthase trafficking
Cell tension controlling pathways and nutrient availability regulate plasma membrane ATP synthase trafficking Open
Introduction: The interplay between mechanical stress and cell metabolism is an emerging topic. However, the mechanotransduction pathways coordinating cell metabolism to the tensional status of the cell are poorly understood. Here, we prov…
View article: Neutrino physics with an opaque detector
Neutrino physics with an opaque detector Open
In 1956 Reines & Cowan discovered the neutrino using a liquid scintillator detector. The neutrinos interacted with the scintillator, producing light that propagated across transparent volumes to surrounding photo-sensors. This approach has…
View article: Performance study of a 3×1×1 m<sup>3</sup> dual phase liquid Argon Time Projection Chamber exposed to cosmic rays
Performance study of a 3×1×1 m<sup>3</sup> dual phase liquid Argon Time Projection Chamber exposed to cosmic rays Open
We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3×1×1 m 3 ) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of the TPC's resp…
View article: Novel liquid neutrino detection technology (a few examples of) what to do with it? & (a minimalistic) how?
Novel liquid neutrino detection technology (a few examples of) what to do with it? & (a minimalistic) how? Open
Parallel Contributed Talk at the "XIX International Workshop on Neutrino Telescopes" on line - 18-26 February, 2021
View article: Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC
Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC Open
The 3×1×1 m3 demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performance of …
View article: First testing of the Hamamatsu R5912-02Mod photomultiplier tube at 4-bar pressure and cryogenic temperature
First testing of the Hamamatsu R5912-02Mod photomultiplier tube at 4-bar pressure and cryogenic temperature Open
The Hamamatsu R5912-02Mod photomultiplier tube (PMT) will be used in the DUNE dual-phase module, a 10-kton fiducial volume liquid-argon time-projection chamber, which is one of the four projected far-detector modules of the DUNE long-basel…
View article: International Large Detector: Interim Design Report
International Large Detector: Interim Design Report Open
The ILD detector is proposed for an electron-positron collider with collision centre-of-mass energies from 90~\GeV~to about 1~\TeV. It has been developed over the last 10 years by an international team of scientists with the goal to design…
View article: Irradiation aging of the CMS Drift Tube muon detector
Irradiation aging of the CMS Drift Tube muon detector Open
View article: The ILD detector at the ILC
The ILD detector at the ILC Open
The International Large Detector, ILD, is a detector concept which has been developed for the electron-positron collider ILC. The detector has been optimized for precision physics in a range of energies between 90 GeV and 1 TeV. ILD featur…
View article: Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC
Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC Open
The CMS drift tubes (DT) muon detector, built for withstanding the LHC\nexpected integrated and instantaneous luminosities, will be used also in the\nHigh Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and,\nconsequen…
View article: The ILD detector at the ILC
The ILD detector at the ILC Open
The International Large Detector, ILD, is a detector concept which has been developed for the electron-positron collider ILC. The detector has been optimized for precision physics in a range of energies between 90 GeV and 1 TeV. ILD featur…
View article: Study of the Effects of Radiation at the CERN Gamma Irradiation Facility on the CMS Drift Tube Muon Detector for HL-LHC
Study of the Effects of Radiation at the CERN Gamma Irradiation Facility on the CMS Drift Tube Muon Detector for HL-LHC Open
The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently…
View article: Analysis of testbeam data of the highly granular RPC-steel CALICE digital hadron calorimeter and validation of Geant4 Monte Carlo models
Analysis of testbeam data of the highly granular RPC-steel CALICE digital hadron calorimeter and validation of Geant4 Monte Carlo models Open
View article: Characterisation of different stages of hadronic showers using the CALICE Si-W ECAL physics prototype
Characterisation of different stages of hadronic showers using the CALICE Si-W ECAL physics prototype Open