View article: Kaolin-based glass-ceramic glaze for cordierite based high-voltage insulators
Kaolin-based glass-ceramic glaze for cordierite based high-voltage insulators Open
With the increase in the demand for electricity the improvement of the distribution system also starts to get special attention. Electricity is transferred over long distances; thus, the distribution related losses should be minimized. Con…
View article: Young’s Modulus of Different Illitic Clays during Heating and Cooling Stage of Firing
Young’s Modulus of Different Illitic Clays during Heating and Cooling Stage of Firing Open
Dynamical thermomechanical analysis of 5 illite-based clays from deposits in Slovakia, Estonia, Latvia, and Hungary is presented. The clays consist of illite (37–80 mass%), quartz (12–48 mass%), K-feldspar (4–13 mass%), kaolinite (0–18 mas…
View article: Evolution of AC conductivity of wet illitic clay during drying
Evolution of AC conductivity of wet illitic clay during drying Open
The evolution of the AC electrical conductivity during drying as well as the relationship between sample volume and moisture of green illite samples were investigated. The samples were prepared from illitic clay (80 mass % illite, 4 mass %…
View article: Modeling of a heat capacity peak and an enthalpy jump for a paraffin-based phase-change material
Modeling of a heat capacity peak and an enthalpy jump for a paraffin-based phase-change material Open
Rubitherm RT 27 is a paraffin-based phase-change material (PCM) in which a change between a solid and liquid phase is used to store/release thermal energy. Its enthalpy and heat capacity, as measured in a quasistatic regime by adiabatic sc…
View article: THERMOMECHANICAL ANALYSIS OF ILLITE FROM FÜZÉRRADVÁNY
THERMOMECHANICAL ANALYSIS OF ILLITE FROM FÜZÉRRADVÁNY Open
Young’s modulus of green illite from Füzérradvány (Hungary) was measured in-situ in the temperature interval 20 °C – 1100 °C and auxiliary analyses DTA, TG and TDA, XRD and EGA, were also performed. It was found that a removal of the physi…
View article: Uncertainty Of The Measurement Of DC Conductivity Of Eramics At Elevated Temperatures
Uncertainty Of The Measurement Of DC Conductivity Of Eramics At Elevated Temperatures Open
The electrical DC conductivity is measured at room and elevated temperatures on green ceramic samples prepared from kaolin. The arrangement of the sample, with two platinum wire electrodes inserted in the kaolin prism that was used is suit…