Lorenzo Marcon
YOU?
Author Swipe
View article: Dysfunctional Implantable Loop Recorder Post‐Electrical Cardioversion: A Report of Two Cases
Dysfunctional Implantable Loop Recorder Post‐Electrical Cardioversion: A Report of Two Cases Open
We report two occurrences of implantable loop recorder (ILR) dysfunction following electrical cardioversion, likely due to anterior–posterior patch positioning. Close proximity to the electrical field may affect ILRs, emphasizing the need …
View article: Pulsed-field ablation beyond pulmonary vein for persistent atrial fibrillation: efficacy and impact on left atrial function
Pulsed-field ablation beyond pulmonary vein for persistent atrial fibrillation: efficacy and impact on left atrial function Open
View article: Comparison of Two High‐Power Ablation Strategies for Typical Atrial Flutter: Acute and Long‐Term Outcome
Comparison of Two High‐Power Ablation Strategies for Typical Atrial Flutter: Acute and Long‐Term Outcome Open
Background Ablation of the cavo‐tricuspid isthmus (CTI) is the standard treatment for typical atrial flutter. High‐power strategies have been described to improve lesion efficacy and durability. Objective To compare the acute success, safe…
View article: Pulmonary vein isolation durability with fluoroscopy or 3D mapping-guided radiofrequency balloon ablation: a mandated remap study
Pulmonary vein isolation durability with fluoroscopy or 3D mapping-guided radiofrequency balloon ablation: a mandated remap study Open
Background Effective balloon positionnking during pulmonary vein isolation (PVI) with a radiofrequency balloon (RFB) is crucial for optimal energy delivery, maximising lesion formation, and preventing gaps. Traditionally, fluoroscopy is us…
View article: Spontaneous type 1 ECG and arrhythmic risk in Brugada syndrome: A meta-analysis of adjusted time-to-event data
Spontaneous type 1 ECG and arrhythmic risk in Brugada syndrome: A meta-analysis of adjusted time-to-event data Open
View article: Multielectrode catheter-based pulsed electric field vs. cryoballoon for atrial fibrillation ablation: a systematic review and meta-analysis
Multielectrode catheter-based pulsed electric field vs. cryoballoon for atrial fibrillation ablation: a systematic review and meta-analysis Open
Aims Pulsed field ablation (PFA) is an innovative technology recently adopted for the treatment of atrial fibrillation (AF). Preclinical and clinical studies have reported a remarkable safety profile, as a result of its tissue-specific eff…
View article: Multielectrode catheter-based pulsed field ablation of persistent and long-standing persistent atrial fibrillation
Multielectrode catheter-based pulsed field ablation of persistent and long-standing persistent atrial fibrillation Open
Aims Rhythm control of non-paroxysmal atrial fibrillation (AF) is significantly more challenging, as a result of arrhythmia perpetuation promoting atrial substrate changes and AF maintenance. We describe a tailored ablation strategy target…
View article: Focal Pulsed Field Ablation for Premature Ventricular Contractions: A Multicenter Experience
Focal Pulsed Field Ablation for Premature Ventricular Contractions: A Multicenter Experience Open
BACKGROUND: Pulsed field ablation (PFA) is a novel technology for catheter-based atrial arrhythmia treatment. Evidence of its application for ventricular arrhythmia ablation is still limited. In this study, we describe the feasibility and …
View article: Atrial fibrillation burden: Stepping beyond the categorical characterization
Atrial fibrillation burden: Stepping beyond the categorical characterization Open
View article: Continuous Rhythm Monitoring With Implanted Loop Recorders in Children and Adolescents With Brugada Syndrome
Continuous Rhythm Monitoring With Implanted Loop Recorders in Children and Adolescents With Brugada Syndrome Open
View article: Correction to: Implantable loop recorders in patients with Brugada syndrome: <i>the BruLoop study</i>
Correction to: Implantable loop recorders in patients with Brugada syndrome: <i>the BruLoop study</i> Open
View article: Implantable loop recorders in patients with Brugada syndrome: <i>the BruLoop study</i>
Implantable loop recorders in patients with Brugada syndrome: <i>the BruLoop study</i> Open
Background and Aims Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinica…
View article: Pericarditis prophylactic therapy after sinus node–sparing hybrid ablation for inappropriate sinus tachycardia/postural orthostatic sinus tachycardia
Pericarditis prophylactic therapy after sinus node–sparing hybrid ablation for inappropriate sinus tachycardia/postural orthostatic sinus tachycardia Open
View article: Redo procedures after sinus node sparing hybrid ablation for inappropriate sinus tachycardia/postural orthostatic sinus tachycardia
Redo procedures after sinus node sparing hybrid ablation for inappropriate sinus tachycardia/postural orthostatic sinus tachycardia Open
Aims A novel sinus node (SN) sparing hybrid ablation for inappropriate sinus node tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS) has been demonstrated to be an effective and safe therapeutic option in patients with symp…
View article: Pulsed electric field, cryoballoon, and radiofrequency for paroxysmal atrial fibrillation ablation: a propensity score-matched comparison
Pulsed electric field, cryoballoon, and radiofrequency for paroxysmal atrial fibrillation ablation: a propensity score-matched comparison Open
Aims Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. t…
View article: Dynamic changes of left atrial substrate over time following pulmonary vein isolation: the Progress-AF study
Dynamic changes of left atrial substrate over time following pulmonary vein isolation: the Progress-AF study Open
Aims Little is known about dynamic changes of the left atrial (LA) substrate over time in patients with atrial fibrillation (AF). This study aims to evaluate substrate changes following pulmonary vein isolation (PVI). Methods and results I…
View article: Reply by Casella et al to Letter Regarding Article, “Incidence of ventricular arrhythmias related to Covid infection and vaccination in patients with Brugada syndrome: Insights from a large Italian multicenter registry based on continuous rhythm monitoring”
Reply by Casella et al to Letter Regarding Article, “Incidence of ventricular arrhythmias related to Covid infection and vaccination in patients with Brugada syndrome: Insights from a large Italian multicenter registry based on continuous rhythm monitoring” Open
View article: TriGuard Embolic Protection Device in percutaneous cardiac interventions with intracavitary cardiac thrombosis: A case series
TriGuard Embolic Protection Device in percutaneous cardiac interventions with intracavitary cardiac thrombosis: A case series Open
Embolic cerebral protection devices are not routinely used in clinical practice during electrophysiological interventions. We report a case series of patients with intracardiac thrombosis undergoing a percutaneous left atrial appendage (LA…
View article: Cardiac magnetic resonance mapping for the diagnosis of reverse ventricular Takotsubo cardiomyopathy
Cardiac magnetic resonance mapping for the diagnosis of reverse ventricular Takotsubo cardiomyopathy Open
A 37-year-old woman with atypical chest pain was referred to Emergency Department for clinical evaluation. Vital signs at admission were stable, and the physical exam was normal. ECG showed only biphasic T wave in V3 (Panel A). Transthorac…