Robert Montés‐Micó
YOU?
Author Swipe
View article: Analysis of Crystalline Lens Tilt and Decentration Using a Fully Automated Swept-Source Optical Coherence Tomography Biometer
Analysis of Crystalline Lens Tilt and Decentration Using a Fully Automated Swept-Source Optical Coherence Tomography Biometer Open
Purpose To evaluate the repeatability of a fully automated swept-source optical coherence tomography (SS-OCT) biometer to measure healthy crystalline lens decentration and tilt and their correlation with other biometric parameters. Methods…
View article: Accuracy of intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in short and long eyes
Accuracy of intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in short and long eyes Open
Background To compare the accuracy of intraoperative wavefront aberrometry using the ORA VLynk system with different biometry-based formulas in short and long eyes after cataract surgery. Methods This prospective study considered 48 eyes w…
View article: Assessment of corneal epithelial thickness mapping by spectral-domain optical coherence tomography
Assessment of corneal epithelial thickness mapping by spectral-domain optical coherence tomography Open
Background To assess corneal epithelial-thickness (ET) mapping resulting from spectral-domain-optical-coherence-tomography (SD-OCT) by analysing its repeatability and reproducibility and its utility for screening corneal-refractive-surgery…
View article: Axial length acquisition success rates and agreement of two swept-source optical biometers in eyes with dense cataracts
Axial length acquisition success rates and agreement of two swept-source optical biometers in eyes with dense cataracts Open
Background Swept-source optical coherence tomography–based (SS-OCT) biometers have been used in different clinical studies with the aim of assessing the accuracy of the technique, specifically in eyes with dense cataracts. Our objective is…
View article: Recognition vs resolution charts for defocus curve determination in trifocal intraocular lenses
Recognition vs resolution charts for defocus curve determination in trifocal intraocular lenses Open
Purpose: To determine the impact of optotype choice on the determination of defocus curve in patients with cataract implanted with presbyopia-correcting intraocular lens (IOL). Setting: Oftalvist Alicante, Alicante, Spain. Design: Observat…
View article: Precision of a new SS-OCT biometer to measure anterior segment parameters and agreement with 3 instruments with different measurement principles
Precision of a new SS-OCT biometer to measure anterior segment parameters and agreement with 3 instruments with different measurement principles Open
Purpose: To evaluate the repeatability of a new swept source optical coherence tomography (SS-OCT)–based biometer to measure anterior segment parameters and to assess the agreement with 3 other imaging devices based on different measuremen…
View article: Axial length acquisition success rates and agreement of four optical biometers and one ultrasound biometer in eyes with dense cataracts
Axial length acquisition success rates and agreement of four optical biometers and one ultrasound biometer in eyes with dense cataracts Open
Background To evaluate the axial length acquisition success rates and agreement between various biometric parameters obtained with different biometers in dense cataracts. Methods Fifty-one eyes were measured using Anterion®, Argos® and IOL…
View article: Vision-related Quality of Life After Cataract Surgery in West Africa
Vision-related Quality of Life After Cataract Surgery in West Africa Open
AIMS To study the vision related quality of life (VRQoL) before and after a mass cataract surgery campaign in a low-income country and to describe the impact of cataract surgery on quality of life (QOL). METHODS All the patients who had ca…
View article: Evaluation of Physiological Parameters on Discomfort Glare Thresholds Using LUMIZ 100 Tool
Evaluation of Physiological Parameters on Discomfort Glare Thresholds Using LUMIZ 100 Tool Open
Light sensitivity is highly subjective and variable across the population. Patients frequently complain about light bothering their daily lives. Accessible physiological factors and questionnaires are unable to predict discomfort levels du…
View article: Evaluation of 6 biometers based on different optical technologies
Evaluation of 6 biometers based on different optical technologies Open
Purpose: To evaluate repeatability and agreement between various biometric parameters using 6 biometers based on different optical technologies. Setting: University of Valencia, Spain. Design: Prospective, comparative case series. Methods:…
View article: Ocular biometry with swept-source optical coherence tomography
Ocular biometry with swept-source optical coherence tomography Open
This study aimed to summarize the outcomes reported when swept-source optical coherence tomography (SS-OCT) is used for ocular biometry. A literature search was performed to identify publications reporting clinical outcomes of patients mea…
View article: Performance of a new device for the clinical determination of light discomfort
Performance of a new device for the clinical determination of light discomfort Open
The new device provides good intrasession repeatability for the clinical determination of light discomfort thresholds, although variance is slightly greater between sessions. The system is useful for the clinical determination of light dis…
View article: Posterior‐chamber phakic implantable collamer lenses with a central port: a review
Posterior‐chamber phakic implantable collamer lenses with a central port: a review Open
We aimed to summarize the outcomes reported following the implantation of the V4c implantable collamer lens with a central port (ICL, STAAR Surgical Inc) for myopia correction. A literature search in PubMed, Web of Science and Scopus was c…
View article: Angle-to-angle and spur-to-spur distance analysis with high-resolution optical coherence tomography
Angle-to-angle and spur-to-spur distance analysis with high-resolution optical coherence tomography Open
Background To measure angle-to-angle (ATA) and spur-to-spur (STS) distances along six meridians using high-resolution swept-source optical coherence tomography (SS-OCT) and to compare those values with horizontal white-to-white (WTW) dista…
View article: Posterior-Chamber Phakic Intraocular Lens Implantation in Patients over 40 Years of Age
Posterior-Chamber Phakic Intraocular Lens Implantation in Patients over 40 Years of Age Open
Purpose . To assess the efficacy, safety, and predictability of the Visian Implantable Collamer Lens (ICL) model having a central port in patients over 40 years of age. Methods . This study included 33 eyes from 21 patients who underwent V…
View article: Visual And Refractive Outcomes In Hyperopic Pseudophakic Patients Implanted With A Trifocal Intraocular Lens
Visual And Refractive Outcomes In Hyperopic Pseudophakic Patients Implanted With A Trifocal Intraocular Lens Open
José F Alfonso,1,2 Andrés Fernández-Vega-Cueto,1 Belén Alfonso-Bartolozzi,1 Ignacio Rodríguez-Uña,1 Robert Montés-Micó3 1Corneal and Lens Surgery Depar…
View article: <p>Visual And Refractive Outcomes In Hyperopic Pseudophakic Patients Implanted With A Trifocal Intraocular Lens</p>
Visual And Refractive Outcomes In Hyperopic Pseudophakic Patients Implanted With A Trifocal Intraocular Lens Open
Bilateral implantation of a trifocal IOL in hyperopic eyes provided good visual and refractive outcomes. The Barrett Universal II formula was accurate in predicting the IOL power in hyperopic eyes.
View article: Visual Function after Implantation of a Presbyopia-Correcting Trifocal Intraocular Lens
Visual Function after Implantation of a Presbyopia-Correcting Trifocal Intraocular Lens Open
Purpose: To evaluate distance, intermediate, and near visual performance in patients implanted with a trifocal aspheric presbyopia-correcting intraocular lens (IOL). Methods: Forty patients were bilaterally implanted with the AcrySofIQ Pan…
View article: Five-Year Follow-up of Correction of Myopia: Posterior Chamber Phakic Intraocular Lens With a Central Port Design
Five-Year Follow-up of Correction of Myopia: Posterior Chamber Phakic Intraocular Lens With a Central Port Design Open
PURPOSE: To assess the long-term correction of moderate to high myopia using a posterior chamber phakic intraocular lens with a central port design. METHODS: Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, int…
View article: Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography
Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography Open
Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes.…
View article: Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography Open
Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per p…
View article: Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography Open
Sept-source optical coherence tomography based lens thickness measurements while wearing soft contact lenses are comparable to those of the naked eye. However, the thickness and the optical design of the soft contact lens may lead to signi…
View article: Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography Open
Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per p…
View article: Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography
Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography Open
The anterior ciliary muscle area tends to increase with accommodation, although the increase has been shown to be symmetric between the pair sectors superior-nasal and inferior-temporal. These results may help to increase understanding of …
View article: Implantable collamer lens with central hole: 3-year follow-up
Implantable collamer lens with central hole: 3-year follow-up Open
The visual and refractive outcomes were very good and highly stable throughout the follow-up period, indicating that this ICL model may be predictable, stable, safe, and effective to correct myopia in the long term.