View article: Development of device for determination of the neutron source emission rate based on the manganese bath technique in the Slovak Institute of Metrology
Development of device for determination of the neutron source emission rate based on the manganese bath technique in the Slovak Institute of Metrology Open
Slovak Institute of Metrology (SMU) as a National Metrology Institute in Slovakia received funding from Slovak Research and Development Agency for developing a manganese bath under the project No.: APVV-21-0170 in 2022. The main contributi…
View article: Cross-section induced uncertainties for manganese sulphate bath technique
Cross-section induced uncertainties for manganese sulphate bath technique Open
The analysis presented in the paper is focused on the characterization of uncertainties induced by cross-section data in the correction factor calculation for the manganese sulphate bath technique. The manganese sulphate bath is the most c…
View article: Cross-section induced uncertainties in neutron source mission rate calculations
Cross-section induced uncertainties in neutron source mission rate calculations Open
Analysis presented in the paper is focused on the characterization of uncertainties induced by cross-section data, which contributing to the overall uncertainty of the correction factors. Advances in computational methods and computational…
View article: The Metrological Traceability, Performance and Precision of European Radon Calibration Facilities
The Metrological Traceability, Performance and Precision of European Radon Calibration Facilities Open
An interlaboratory comparison for European radon calibration facilities was conducted to evaluate the establishment of a harmonized quality level for the activity concentration of radon in air and to demonstrate the performance of the faci…
View article: The CCRI(II)-K2.Fe-55.2019 key comparison of activity concentration measurements of a <sup>55</sup> Fe solution
The CCRI(II)-K2.Fe-55.2019 key comparison of activity concentration measurements of a <sup>55</sup> Fe solution Open
Main text A comparison of the activity concentration of an 55 Fe solution was organized by the POLATOM under the auspices of the CCRI(II). The solution was sent to thirteen laboratories; ready-to-measure sources were also prepared using th…
View article: International comparison of activity measurements of radon 222 - EURAMET Project n°1475 - EURAMET.RI(II)-S8.Rn-222
International comparison of activity measurements of radon 222 - EURAMET Project n°1475 - EURAMET.RI(II)-S8.Rn-222 Open
Main text An international comparison of activity per unit volume of 222 Rn (EURAMET project N° 1475, registered in KCDB as supplementary comparison EURAMET.RI(II)-S8.Rn-222) was organised in 2019 within the framework of the European proje…