Mathieu Dupont
YOU?
Author Swipe
View article: Validation of optical pathlength stability in a LISA test-bench demonstrator
Validation of optical pathlength stability in a LISA test-bench demonstrator Open
The Laser Interferometer Space Antenna (LISA) observatory is a future L3 mission of the European Space Agency (ESA) to detect gravitational waves, set to launch in 2035. The detector constellation will conduct interferometry to picometer s…
View article: Propagation of Uncertainties in estimates of the Compton Cone Aperture Angle Using Monte Carlo Simulations and Analytical Models: A Comparative Analysis
Propagation of Uncertainties in estimates of the Compton Cone Aperture Angle Using Monte Carlo Simulations and Analytical Models: A Comparative Analysis Open
View article: The HDAC inhibitor romidepsin renders liver cancer vulnerable to RTK targeting and immunologically active
The HDAC inhibitor romidepsin renders liver cancer vulnerable to RTK targeting and immunologically active Open
View article: Tracing specificity of immune landscape remodeling associated with distinct anticancer treatments
Tracing specificity of immune landscape remodeling associated with distinct anticancer treatments Open
View article: APLOSE: A web-based annotation platform for underwater passive acoustic monitoring
APLOSE: A web-based annotation platform for underwater passive acoustic monitoring Open
View article: A Fast Plastic Scintillator for Low-Intensity Proton Beam Monitoring
A Fast Plastic Scintillator for Low-Intensity Proton Beam Monitoring Open
In the context of particle therapy monitoring, we are developing a gamma-ray\ndetector to determine the ion range in vivo from the measurement of particle\ntime-of-flight. For this application, a beam monitor capable to tag in time the\nin…
View article: β <sup>+</sup> surgical radio-guidance using a small Compton-angles collimation probe
β <sup>+</sup> surgical radio-guidance using a small Compton-angles collimation probe Open
The fields of radio-guided surgery and interventional nuclear medicine benefit from a growing array of technologies that aid novel healthcare interventions. Among them, surgery probes able to efficiently detect β + emitters are essential t…
View article: Characterization of IMIC, an implantable needle-shaped positron sensitive monolithic active pixel sensor for preclinical molecular neuroimaging
Characterization of IMIC, an implantable needle-shaped positron sensitive monolithic active pixel sensor for preclinical molecular neuroimaging Open
View article: Design of Temperature Dependent Critical Experiments with SPRF/CX
Design of Temperature Dependent Critical Experiments with SPRF/CX Open
This paper describes the investigation of temperature-dependent critical experiments using the Seven Percent Critical Experiments (7uPCX) and Burnup Credit Critical Experiments (BUCCX) fuel types within the Sandia Pulsed Reactor Facility/C…
View article: Aplose: A Scalable Web-Based Annotation Platform for Underwater Passive Acoustic Monitoring
Aplose: A Scalable Web-Based Annotation Platform for Underwater Passive Acoustic Monitoring Open
View article: Current Progress of the Final Design of a Subcritical Assembly at the Oak Ridge National Laboratory
Current Progress of the Final Design of a Subcritical Assembly at the Oak Ridge National Laboratory Open
During the past decade, the US Department of Energy (DOE)/National Nuclear Security Administration (NNSA) Nuclear Criticality Safety Program (NCSP) has been coordinating nuclear criticality safety (NCS) courses to provide training and qual…
View article: First ClearMind gamma detector prototype for TOF-PET imaging
First ClearMind gamma detector prototype for TOF-PET imaging Open
The ClearMind project aims to develop a TOF-PET position-sensitive detection module optimized for time and spatial resolutions and detection efficiency. For this, we use a 59 mm $\times$ 59 mm $\times$ 5 mm monolithic PbWO$_4$ (PWO) crysta…
View article: A high sensitivity Cherenkov detector for prompt gamma timing and time imaging
A high sensitivity Cherenkov detector for prompt gamma timing and time imaging Open
We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the…
View article: Monte Carlo simulation of a scintillation crystal read by a SiPM with GATE
Monte Carlo simulation of a scintillation crystal read by a SiPM with GATE Open
View article: Current Progress of the Final Design of a Subcritical Assembly at Oak Ridge National Laboratory [Slides]
Current Progress of the Final Design of a Subcritical Assembly at Oak Ridge National Laboratory [Slides] Open
This presentation shows how ORSA design has moved from conceptual to implementable. Additionally, that the ORSA hands-on experiments will remain subcritical under normal and credible abnormal conditions it is fully assembled keff
View article: Detailed simulation for the ClearMind prototype detection module and event reconstruction using artificial intelligence
Detailed simulation for the ClearMind prototype detection module and event reconstruction using artificial intelligence Open
The ClearMind project aims to develop the TOF-PET position sensitive detection module optimized for the time resolution, spatial resolution, and detection efficiency. For this, the ClearMind project uses a large (59 $\times$ 59 mm$^2$) mon…
View article: Monte Carlo simulation of SiPMs with GATE
Monte Carlo simulation of SiPMs with GATE Open
Silicon photomultipliers (SiPMs) replace photomultiplier tubes (PMTs) for the detection of light in many applications, particularly in high energy physics and medical imaging. We describe a flexible implementation of a SiPM model for the G…
View article: Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Critical Benchmark Creation [Slides]
Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Critical Benchmark Creation [Slides] Open
During the evaluation of Oak Ridge National Laboratory Health Physics Research Reactor operation data for critical benchmark creation, a detailed, functional SCALE model was built, and experimental data was evaluated for the creation of a …
View article: Horizontal Split Table Conceptual Design for Advanced Reactor Validation
Horizontal Split Table Conceptual Design for Advanced Reactor Validation Open
Oak Ridge National Laboratory and Lawrence Livermore National Laboratory are collaborating to develop a conceptual design for a horizontal split table for use in performing critical experiments. The goal of this design effort is to provide…
View article: A Subcritical Assembly for Training and Education Use at the Oak Ridge National Laboratory
A Subcritical Assembly for Training and Education Use at the Oak Ridge National Laboratory Open
A near-final design has been completed for a new subcritical assembly at Oak Ridge National Laboratory (ORNL). This subcritical assembly will support the Nuclear Criticality Safety Program (NCSP) training and education program to augment c…
View article: Expansion of the ORNL VALID Library
Expansion of the ORNL VALID Library Open
View article: Modelisation of Light Transmission through Surfaces with Thin Film Optical Coating in Geant4
Modelisation of Light Transmission through Surfaces with Thin Film Optical Coating in Geant4 Open
International audience
View article: IER-539 CED-1: Preliminary Design of a New Horizontal Split Table
IER-539 CED-1: Preliminary Design of a New Horizontal Split Table Open
This report presents the preliminary design (CED-1) of IER-539, focused on a new Horizontal Split Table (HST) critical assembly machine. The Department of Energy (DOE) National Nuclear Criticality Safety Program (NCSP) funds critical exper…
View article: Advanced Monte Carlo simulations of emission tomography imaging systems with GATE
Advanced Monte Carlo simulations of emission tomography imaging systems with GATE Open
Built on top of the Geant4 toolkit, GATE is collaboratively developed for more than 15 years to design Monte Carlo simulations of nuclear-based imaging systems. It is, in particular, used by researchers and industrials to design, optimize,…
View article: ProMeSCT: A Proximal Metric Algorithm for Spectral CT
ProMeSCT: A Proximal Metric Algorithm for Spectral CT Open
The acquisition of a set of spectral photon-counting computed tomography (spectral PC-CT) measurements aims at uncovering both the spatial and energetic characteristics of the imaged body, which widens the potential of tomography compared …
View article: Tracking Dynamics of Spontaneous Tumors in Mice Using Photon-Counting Computed Tomography
Tracking Dynamics of Spontaneous Tumors in Mice Using Photon-Counting Computed Tomography Open
View article: Tracking Dynamics of Spontaneous Tumours in Mice Using Photon Counting Computed Tomography
Tracking Dynamics of Spontaneous Tumours in Mice Using Photon Counting Computed Tomography Open
View article: Analyse de l’évolution des pratiques de prise en charge du cancer différencié de la thyroïde de plus de 1 cm au CHU de Nancy de 2010 à 2014
Analyse de l’évolution des pratiques de prise en charge du cancer différencié de la thyroïde de plus de 1 cm au CHU de Nancy de 2010 à 2014 Open