Matthias Hammon
YOU?
Author Swipe
View article: Improved Visualization of Prostate Cancer Using Multichannel Computed Diffusion Images: Combining ADC and DWI
Improved Visualization of Prostate Cancer Using Multichannel Computed Diffusion Images: Combining ADC and DWI Open
(1) Background: For the peripheral zone of the prostate, diffusion weighted imaging (DWI) is the most important MRI technique; however, a high b-value image (hbDWI) must always be evaluated in conjunction with an apparent diffusion coeffic…
View article: Serum miRNAs Support the Indication for MRI-Ultrasound Fusion-Guided Biopsy of the Prostate in Patients with Low-PI-RADS Lesions
Serum miRNAs Support the Indication for MRI-Ultrasound Fusion-Guided Biopsy of the Prostate in Patients with Low-PI-RADS Lesions Open
Multiparametric MRI (mpMRI) and targeted biopsy of the prostate enhance the tumor detection rate. However, the prediction of clinically significant prostate cancer (PCa) is still limited. Our study tested the additional value of serum leve…
View article: Potential for Radiation Dose Reduction in Dual-Source Computed Tomography of the Lung in the Pediatric and Adolescent Population Compared to Digital Radiography
Potential for Radiation Dose Reduction in Dual-Source Computed Tomography of the Lung in the Pediatric and Adolescent Population Compared to Digital Radiography Open
Low-dose dual-source computed tomography (DSCT) protocols for the evaluation of lung diseases in children and adolescents are of importance since this age group is particularly prone to radiation damage. The aim of this study was to evalua…
View article: Scanned versus Fused-Reconstructed Oblique MR-Images for Assessment of the Tibiofibular Syndesmosis—Diagnostic PerFormance and Reader Agreement
Scanned versus Fused-Reconstructed Oblique MR-Images for Assessment of the Tibiofibular Syndesmosis—Diagnostic PerFormance and Reader Agreement Open
To evaluate the diagnostic performance and reader agreement of a novel MRI image fusion method enabling the reconstruction of oblique images for the assessment of the tibiofibular syndesmosis. We evaluated 40 magnetic resonance imaging exa…
View article: Computer-Aided Diagnosis in Multiparametric MRI of the Prostate: An Open-Access Online Tool for Lesion Classification with High Accuracy
Computer-Aided Diagnosis in Multiparametric MRI of the Prostate: An Open-Access Online Tool for Lesion Classification with High Accuracy Open
Computer-aided diagnosis (CADx) approaches could help to objectify reporting on prostate mpMRI, but their use in many cases is hampered due to common-built algorithms that are not publicly available. The aim of this study was to develop an…
View article: Breast MRI texture analysis for prediction of BRCA-associated genetic risk
Breast MRI texture analysis for prediction of BRCA-associated genetic risk Open
View article: Dual-source computed tomography of the lung with spectral shaping and advanced iterative reconstruction: potential for maximum radiation dose reduction
Dual-source computed tomography of the lung with spectral shaping and advanced iterative reconstruction: potential for maximum radiation dose reduction Open
View article: Small direct right ventricular cardiac metastasis of osteosarcoma in a 10-year-old boy affirmed by cardiac MRI
Small direct right ventricular cardiac metastasis of osteosarcoma in a 10-year-old boy affirmed by cardiac MRI Open
View article: Automated volumetric radiomic analysis of breast cancer vascularization improves survival prediction in primary breast cancer
Automated volumetric radiomic analysis of breast cancer vascularization improves survival prediction in primary breast cancer Open
Implementation of machine learning into clinical breast MRI: Potential for objective and accurate decision-making in suspicious breast masses Open
View article: A mixed waveform protocol for reduction of the cardiac motion artifact in black-blood diffusion-weighted imaging of the liver
A mixed waveform protocol for reduction of the cardiac motion artifact in black-blood diffusion-weighted imaging of the liver Open
It is recommendable to use the following mixed waveform protocol: Monopolar diffusion encodings at small b-values and flow-compensated diffusion encodings at high b-values.
View article: Dynamic CT angiography for therapy evaluation after transarterial chemoembolization of hepatocellular carcinoma
Dynamic CT angiography for therapy evaluation after transarterial chemoembolization of hepatocellular carcinoma Open
Background Liver dynamic computed tomography (CT) is an established method for pre- and post-interventional evaluation of hepatocellular carcinoma. To date only the liver parenchyma and perfusion information of dynamic CT has been evaluate…
View article: Improved visualization of peripherally inserted central catheters on chest radiographs of neonates using fractional multiscale image processing
Improved visualization of peripherally inserted central catheters on chest radiographs of neonates using fractional multiscale image processing Open
View article: Effect of Compression Garments on the Development of Edema and Soreness in Delayed-Onset Muscle Soreness (DOMS).
Effect of Compression Garments on the Development of Edema and Soreness in Delayed-Onset Muscle Soreness (DOMS). Open
Delayed-onset muscle soreness (DOMS), an ultrastructural muscle injury, is one of the most common reasons for impaired muscle performance. The purpose of this study was to investigate the influence of sport compression garments on the deve…
View article: Extent of simultaneous radiation dose and iodine reduction at stable image quality in computed tomography of the chest
Extent of simultaneous radiation dose and iodine reduction at stable image quality in computed tomography of the chest Open
Simultaneous reductions in iodine dosage and radiation dose by one-third are feasible for CT of the chest.
View article: 4116Reduction of tissue sodium content by SGLT-2-inhibition with dapagliflozin
4116Reduction of tissue sodium content by SGLT-2-inhibition with dapagliflozin Open
View article: Semi-automated De-identification of German Content Sensitive Reports for Big Data Analytics
Semi-automated De-identification of German Content Sensitive Reports for Big Data Analytics Open
Correction to: Semi-automated De-identification of German Content Sensitive Reports for Big Data AnalyticsRofo eFirstDOI: 10.1055/s-0043-102939
View article: Na+ deposition in the fibrotic skin of systemic sclerosis patients detected by 23Na-magnetic resonance imaging
Na+ deposition in the fibrotic skin of systemic sclerosis patients detected by 23Na-magnetic resonance imaging Open
View article: Semi-automated De-identification of German Content Sensitive Reports for Big Data Analytics
Semi-automated De-identification of German Content Sensitive Reports for Big Data Analytics Open
Purpose Projects involving collaborations between different institutions require data security via selective de-identification of words or phrases. A semi-automated de-identification tool was developed and evaluated on different types of m…
View article: Breast MRI at Very Short TE (minTE): Image Analysis of minTE Sequences on Non-Fat-Saturated, Subtracted T1-Weighted Images
Breast MRI at Very Short TE (minTE): Image Analysis of minTE Sequences on Non-Fat-Saturated, Subtracted T1-Weighted Images Open
Purpose The aim was to evaluate a minimum echo time (minTE) protocol for breast magnetic resonance imaging (MRI) in patients with breast lesions compared to a standard TE (nTE) time protocol. Methods Breasts of 144 women were…
View article: Automated Semi-Quantitative Analysis of Breast MRI: Potential Imaging Biomarker for the Prediction of Tissue Response to Neoadjuvant Chemotherapy
Automated Semi-Quantitative Analysis of Breast MRI: Potential Imaging Biomarker for the Prediction of Tissue Response to Neoadjuvant Chemotherapy Open
Background: We aimed to investigate an automated semi-quantitative software as an imaging biomarker for the prediction of tissue response (TR) after completion of neoadjuvant chemotherapy (NAC). Methods: Breast …
View article: Editorial Board / Contents / Imprint
Editorial Board / Contents / Imprint Open
View article: Society Bulletins
Society Bulletins Open
View article: Meetings and Conferences
Meetings and Conferences Open
View article: Development and Evaluation of a Semi-automated Segmentation Tool and a Modified Ellipsoid Formula for Volumetric Analysis of the Kidney in Non-contrast T2-Weighted MR Images
Development and Evaluation of a Semi-automated Segmentation Tool and a Modified Ellipsoid Formula for Volumetric Analysis of the Kidney in Non-contrast T2-Weighted MR Images Open
View article: Na+ deposition in the fibrotic skin of systemic sclerosis patients detected by 23Na-magnetic resonance imaging
Na+ deposition in the fibrotic skin of systemic sclerosis patients detected by 23Na-magnetic resonance imaging Open
23 Na-MRI detected increased Na + in the fibrotic SSc skin; high Na + content was associated with progressive skin disease. Our findings provide the first evidence that 23 Na-MRI might be a promising tool to assess skin Na + and thereby pr…
View article: Semiautomatic segmentation of the kidney in magnetic resonance images using unimodal thresholding
Semiautomatic segmentation of the kidney in magnetic resonance images using unimodal thresholding Open
Unimodal thresholding of native MR images is a robust and sufficiently reliable method for kidney segmentation and volumetric analysis. The manual pre-segmentation can be done by non-experts with little introduction.
View article: Dose reduction potential of iterative reconstruction algorithms in neck CTA—a simulation study
Dose reduction potential of iterative reconstruction algorithms in neck CTA—a simulation study Open
Neck CTA can be performed with substantially less radiation dose when SAFIRE is applied. The exact degree of radiation dose reduction should be adapted to the clinical question, in particular to the smallest vessel needing excellent defini…
View article: Quantitative assessment of muscle injury by 23Na magnetic resonance imaging
Quantitative assessment of muscle injury by 23Na magnetic resonance imaging Open
View article: Osteoblastic lesion screening with an advanced post-processing package enabling in-plane rib reading in CT-images
Osteoblastic lesion screening with an advanced post-processing package enabling in-plane rib reading in CT-images Open