Michael V. Orlov
YOU?
Author Swipe
Procedural Outcomes and Conduction System Capture Pattern Maintenance With the Tendril STS™ 2088TC Lead and CPS Locator™ 3D Delivery System: A Comparative Analysis With Lumenless Lead System Open
Introduction Left bundle branch area pacing (LBBAP) is typically performed using the lumenless (LLL) Medtronic SelectSecure TM Model 3830 pacing lead. Stylet‐driven leads (SDL) for LBBAP were recently introduced. Objective To compare the A…
Global voices: Providing medical care in a war-torn country Open
Uma N Srivatsa, MBBS, MS, FHRS—Section Editor Global Voices (Sacramento, California): Cardiac electrophysiologists are immensely specialized, highly focused, and committed to an intuitive and imaginative realm only they understand and can …
Review of: "A Guide to Left Bundle Branch Area Pacing Using Stylet-Driven Pacing Leads" Open
Potential competing interests: The author(s) declared that no potential competing interests exist.Jan De Pooter et al. present a comprehensive guide to left bundle branch area pacing using stylet driven pacing leads.The experience with the…
On the Management of Ventricular Arrhythmias Following Leadless Pacemaker Implantation Open
Ahmad et al. 1 present an interesting case of a patient undergoing leadless pacemaker placement with subsequent ventricular fibrillation (VF) induced cardiopulmonary arrest.As they mention, there are several published case reports of ventr…
Direct left bundle branch pacing can result in dyssynchronous left ventricular contraction and worsening heart failure: a case report Open
A 69 year old male patient with mild non ischemic cardiomyopathy, baseline EF of 47%, received a dual chamber pacemaker with a direct left bundle branch lead for complete heart block. 3830 lead was inserted intraseptally according to publi…
Infectious complications of implantable cardiac devices: diagnosis, management and current guidelines Open
Рекс Л. 3 , ХонШиделер К. 4 , Орлов М.В. 1, 5 Кардиальные имплантируемые устройства (КИУ) широко распространены.Популяция с показаниями к КИУ продолжает увеличиваться и диверсифицироваться, что ведет к росту числа инфекций, связанных с КИУ…
View article: Direct Visualization of the His Bundle Pacing Lead Placement by 3-Dimensional Electroanatomic Mapping
Direct Visualization of the His Bundle Pacing Lead Placement by 3-Dimensional Electroanatomic Mapping Open
Background: His bundle pacing (HBP) remains technically challenging and is currently guided by electrograms and 2-dimensional fluoroscopy. Our objective was to describe a new technique for HBP directly guided by electroanatomic mapping (EA…
View article: Synergy between sacubitril and valsartan leads to hemodynamic, antifibrotic, and exercise tolerance benefits in rats with preexisting heart failure
Synergy between sacubitril and valsartan leads to hemodynamic, antifibrotic, and exercise tolerance benefits in rats with preexisting heart failure Open
Simultaneous neprilysin inhibition (NEPi) and angiotensin receptor blockade (ARB) with sacubitril/valsartan improves cardiac function and exercise tolerance in patients with heart failure. However, it is not known whether these therapeutic…
Clinical Implications of Brief Device-Detected Atrial Tachyarrhythmias in a Cardiac Rhythm Management Device Population Open
Background: The RATE Registry (Registry of Atrial Tachycardia and Atrial Fibrillation Episodes) is a prospective, outcomes-oriented registry designed to document the prevalence of atrial tachycardia and/or fibrillation (AT/AF) of any durat…
Long‐Term Evaluation of Biotronik Linox and Linox<sup>smart</sup> Implantable Cardioverter Defibrillator Leads Open
Long‐Term Evaluation of Biotronik Linox Family of ICD Leads Introduction Expert consensus holds that post‐market, systematic surveillance of ICD leads is essential to ensure confirmation of adequate lead performance. GALAXY (NCT00836589) a…