O. Sasaki
YOU?
Author Swipe
View article: Analysis of Spectral Modification of <i>φ</i> Mesons at Finite Density Using a Transport Approach in 12 GeV pA Reactions
Analysis of Spectral Modification of <i>φ</i> Mesons at Finite Density Using a Transport Approach in 12 GeV pA Reactions Open
The hadron spectrum at finite density is an important observable for exploring the origin of hadron masses. In the KEK-PS E325 experiment, the di-electron decays of $\phi$ mesons inside and outside nuclei were measured using $12 \,\mathrm{…
View article: Velocity Dependence of the Mass Modifications of <i>ρ</i> and <i>ω</i> Mesons in 12 GeV <i>p</i> + <i>A</i> Reactions
Velocity Dependence of the Mass Modifications of <i>ρ</i> and <i>ω</i> Mesons in 12 GeV <i>p</i> + <i>A</i> Reactions Open
This study measured the invariant mass spectra of $\rho$ and $\omega$ mesons in the $e^+e^-$ decay channel for 12 GeV (12.9 GeV/$c$) $p+\mathrm{C}$ and $p+\mathrm{Cu}$ reactions ($\sqrt{s}_{NN}=5.1$ GeV) at the High Energy Accelerator Rese…
View article: Space weathering acts strongly on the uppermost surface of Ryugu
Space weathering acts strongly on the uppermost surface of Ryugu Open
View article: Heat Stroke-Induced Takotsubo Cardiomyopathy With a Concomitant Transient Brugada-Like Electrocardiogram
Heat Stroke-Induced Takotsubo Cardiomyopathy With a Concomitant Transient Brugada-Like Electrocardiogram Open
View article: Conservative Treatment for Isolated Superior Mesenteric Artery Dissection With Severely Narrowed True Lumen
Conservative Treatment for Isolated Superior Mesenteric Artery Dissection With Severely Narrowed True Lumen Open
View article: Earlobe Creases as a Marker of the Risk for Coronary Atherosclerosis Before Angiography in Elderly and Non-elderly Patients
Earlobe Creases as a Marker of the Risk for Coronary Atherosclerosis Before Angiography in Elderly and Non-elderly Patients Open
Background The close relationship between earlobe creases (ELC) and the presence of coronary artery disease (CAD) has been reported. In addition, this study aimed to determine associations between ELC and the presence, extent, and severity…
View article: Partial Arch Replacement Using Common Trunk Perfusion in Type A Acute Aortic Dissection
Partial Arch Replacement Using Common Trunk Perfusion in Type A Acute Aortic Dissection Open
View article: Positron Tracking Detector for Muon <i>g</i> − 2/EDM Experiment at J-PARC
Positron Tracking Detector for Muon <i>g</i> − 2/EDM Experiment at J-PARC Open
View article: Incidental retroaortic innominate vein in a patient with acute aortic dissection
Incidental retroaortic innominate vein in a patient with acute aortic dissection Open
BackgroundRetroaortic innominate vein is a rare anomaly. It has been reported in patients with congenital anomalies such as Tetralogy of Fallot or right aortic arch. However, isolated retroaortic innominate vein is quite rare.Case presenta…
View article: Incidental Retroaortic Innominate Vein in a Patient with Acute Aortic Dissection
Incidental Retroaortic Innominate Vein in a Patient with Acute Aortic Dissection Open
Background Retroaortic innominate vein is a rare anomaly. It has been reported in patients with congenital anomalies such as Tetralogy of Fallot or right aortic arch. However, isolated retroaortic innominate vein is quite rare. Case presen…
View article: Development of a silicon strip detector with high rate capability for pulsed beams
Development of a silicon strip detector with high rate capability for pulsed beams Open
A silicon strip detector for high rate of positrons/electrons is developed to be used at experiments with a high-intensity pulsed muon beam, which is available at the Japan Proton Accelerator Research Complex (J-PARC). The detector consist…
View article: Development of Silicon Strip Detector for J-PARC muon g-2/EDM Experiment
Development of Silicon Strip Detector for J-PARC muon g-2/EDM Experiment Open
The muon anomalous magnetic moment $(g-2)_{\mu}$ and electric dipole moment (EDM) are sensitive to new physics beyond the Standard Model. We aim to measure $(g-2)_{\mu}$ with a precision of 0.1 parts per million and search for EDM with a s…
View article: A new approach for measuring the muon anomalous magnetic moment and electric dipole moment
A new approach for measuring the muon anomalous magnetic moment and electric dipole moment Open
This paper introduces a new approach to measure the muon magnetic moment anomaly a?? = (g - 2)/2 and the muon electric dipole moment (EDM) d?? at the J-PARC muon facility. The goal of our experiment is to measure a?? and d?? using an indep…
View article: A New Approach for Measuring the Muon Anomalous Magnetic Moment and Electric Dipole Moment
A New Approach for Measuring the Muon Anomalous Magnetic Moment and Electric Dipole Moment Open
This paper introduces a new approach to measure the muon magnetic moment anomaly $a_μ = (g-2)/2$, and the muon electric dipole moment (EDM) $d_μ$ at the J-PARC muon facility. The goal of our experiment is to measure $a_μ$ and $d_μ$ using a…
View article: UCG Report on the TDR for the Phase-II Upgrade of the CMS Muon System
UCG Report on the TDR for the Phase-II Upgrade of the CMS Muon System Open
View article: Subnanosecond time-to-digital converter implemented in a Kintex-7 FPGA
Subnanosecond time-to-digital converter implemented in a Kintex-7 FPGA Open
View article: Performances of typical high energy physics applications in flash-based field-programmable gate array under gamma irradiation
Performances of typical high energy physics applications in flash-based field-programmable gate array under gamma irradiation Open
Recent field-programmable gate arrays (FPGAs) based on flash memories offer a high radiation tolerance. We discuss potential applications of the Microsemi IGLOO2 FPGAs in high energy experiments. We implement a 24 channel time-to-digital c…
View article: Short-Time Preparation of NaOH-Activated Carbon from Sugar Cane Bagasse Using Microwave Plasma Heating
Short-Time Preparation of NaOH-Activated Carbon from Sugar Cane Bagasse Using Microwave Plasma Heating Open
The microwave induced argon plasma was applied to the preparation of NaOH-activated carbon from sugar cane bagasse. The distinguished feature of the heating technique with this cold plasma is the short operation time. The carbonization and…
View article: Development of a sub-nanosecond time-to-digital converter based on a field-programmable gate array
Development of a sub-nanosecond time-to-digital converter based on a field-programmable gate array Open
The present time-to-digital converter (TDC) chips for the monitored drift tube (MDT) chambers at the ATLAS experiment will be replaced with new ones for the High-Luminosity LHC, expected to begin operation in 2026. The design and the perfo…
View article: Design of the Positron Tracking Detector for the Muon <i>g</i> − 2/EDM Experiment at J-PARC
Design of the Positron Tracking Detector for the Muon <i>g</i> − 2/EDM Experiment at J-PARC Open
The muon anomalous magnetic moment (g -2) has been measured with a precision of 0.54ppm, which had 3.3σ discrepancy between the SM prediction and measured value.The muon electric dipole moment (EDM) has been constrained down to 10 -19 e • …