P. Krejcik
YOU?
Author Swipe
View article: RECENT IMPROVEMENTS IN THE SLC POSITRON SYSTEM PERFORMANCE
RECENT IMPROVEMENTS IN THE SLC POSITRON SYSTEM PERFORMANCE Open
The positron system is very specific to the SLC in that the positrons are accelerated in the same linac as the electrons that produce them and the electrons with which they collide. Some of the difficulties in tuning this system to peak pe…
View article: New X-Band RF Deflector for Femtosecond Diagnostics of LCLS-II Beams
New X-Band RF Deflector for Femtosecond Diagnostics of LCLS-II Beams Open
An X-band transverse deflector has been successfully developed for femtosecond electron and x-ray pulse temporal diagnostic at the LCLS [1]. The working frequency for the deflector is 11.424 GHz. New free electron laser LCLS-II has two und…
View article: Performance of the SLAC-PAL-Vitzrotech X-band Cavity BPMs in the LCLS-II Undulator Beam Lines
Performance of the SLAC-PAL-Vitzrotech X-band Cavity BPMs in the LCLS-II Undulator Beam Lines Open
The hard X-ray and soft X-Ray undulator beamlines of the LCLS-II X-ray FEL incorporate 65 X-band RF beam position monitors for accurate tracking of the electron beam trajectories and Beam-Based Alignment. For this crucial function, a desig…
View article: Measurements of wake-induced electron beam deflection in a dechirper at the Linac Coherent Light Source
Measurements of wake-induced electron beam deflection in a dechirper at the Linac Coherent Light Source Open
The RadiaBeam/SLAC dechirper, a structure consisting of pairs of flat, metallic, corrugated plates, has been installed just upstream of the undulators in the Linac Coherent Light Source (LCLS). As a dechirper, with the beam passing between…
View article: A simple method for a very short X-ray pulse production and attosecond diagnostic at LCLS
A simple method for a very short X-ray pulse production and attosecond diagnostic at LCLS Open
View article: Development for a supercompact <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mi>X</mml:mi></mml:math>-band pulse compression system and its application at SLAC
Development for a supercompact -band pulse compression system and its application at SLAC Open
Here, we have successfully designed, fabricated, installed, and tested a super compact X -band SLAC Energy Doubler system at SLAC. It is composed of an elegant 3 dB coupler–mode converter–polarizer coupled to a single spherical energy stor…
View article: Sub-fs Resolution with the Enhanced Operation of the X-band Transverse Deflecting Cavity using an RF pulse Compression SLED Cavity
Sub-fs Resolution with the Enhanced Operation of the X-band Transverse Deflecting Cavity using an RF pulse Compression SLED Cavity Open
The successful operation of the x-band transverse deflecting cavity (XTCAV) installed downstream of the LCLS undulator has been further enhanced by the recent addition of an RF pulse compression "SLED" cavity that doubles the temporal reso…
View article: R&D of a Super-compact SLED System at SLAC
R&D of a Super-compact SLED System at SLAC Open
We have successfully designed, fabricated, installed and tested a super-compact X-Band SLED system at SLAC. It is composed of an elegant mode converter/polarizer and a single sphere energy store cavity with high Q of 94000 and diameter les…
View article: Performance of the New Fast Wire Scanner at the LCLS
Performance of the New Fast Wire Scanner at the LCLS Open
A new fast wire scanner based on a linear DC servo motor acting through dual bellows has been developed at SLAC. After successful beam testing at LCLS we are now replacing all the old style stepping motor driven scanners with the new type.…
View article: Commissioning of the RadiaBeam / SLAC Dechirper
Commissioning of the RadiaBeam / SLAC Dechirper Open
We present results on the commissioning of the two-module RadiaBeam / SLAC dechirper system at LCLS. This is the first installation and measurement of a corrugated dechirper at high energy (4.4 - 13.3 GeV), short pulses (< 200 fs) and whil…
View article: RadiaBeam/SLAC Dechirper as a Passive Deflector
RadiaBeam/SLAC Dechirper as a Passive Deflector Open
We discuss the possibility of using the RadiBeam/SLAC dechirper recently installed at LCLS for measuring the bunch length of very short bunches, less than 1 fs perhaps as short as 100 atto second. When a bunch travels close to one of the j…
View article: Transverse Profiling of an Intense FEL X-Ray Beam Using a Probe Electron Beam
Transverse Profiling of an Intense FEL X-Ray Beam Using a Probe Electron Beam Open
Monitoring the pulse by pulse output intensity and profile of an FEL is a critical measurement both for users and for optimising the accelerator drive beam. The diagnostic challenge is to find a technique that is not susceptible to damage …
View article: Implementation of a Corrugated-Plate Dechirping System for GeV Electron Beam at LCLS
Implementation of a Corrugated-Plate Dechirping System for GeV Electron Beam at LCLS Open
A new corrugated-plate Dechirper was recently installed in the LCLS and underwent commissioning tests to gauge its efficacy in shaping the longitudinal phase space of bunches entering the FEL. Here, we describe in detail the completed four…
View article: Generating femtosecond X-ray pulses using an emittance-spoiling foil in free-electron lasers
Generating femtosecond X-ray pulses using an emittance-spoiling foil in free-electron lasers Open
Generation of femtosecond to sub-femtosecond pulses is attracting much attention in X-ray free-electron laser user community. One method is to use a slotted, emittance-spoiling foil which was proposed before (P. Emma et al., Phys. Rev. Let…
View article: LLRF AND HPRF CONTROLS UPGRADE FOR THE LCLS XTCAV PROJECT AT SLAC NATIONAL ACCELERATOR LAB
LLRF AND HPRF CONTROLS UPGRADE FOR THE LCLS XTCAV PROJECT AT SLAC NATIONAL ACCELERATOR LAB Open
View article: Results from the LCLS X-Band Transverse Deflector with Femtosecond Temporal Resolution
Results from the LCLS X-Band Transverse Deflector with Femtosecond Temporal Resolution Open
An X-band RF transverse deflector composed of two 1-m-long X-band deflecting structures has been recently commissioned at the Linac Coherent Light Source (LCLS) at SLAC National Accelerator Laboratory. Located downstream of the FEL undulat…
View article: Flexible control of femtosecond pulse duration and separation using an emittance-spoiling foil in x-ray free-electron lasers
Flexible control of femtosecond pulse duration and separation using an emittance-spoiling foil in x-ray free-electron lasers Open
We report experimental studies of generating and controlling femtosecond x-ray pulses in free-electron lasers (FELs) using an emittance spoiling foil. By selectivity spoiling the transverse emittance of the electron beam, the output pulse …
View article: Fast Wire Scanner Upgrade for LCLS
Fast Wire Scanner Upgrade for LCLS Open
Wire scanners are a main diagnostic tool for transverse beam size and emittance measurements at LCLS. The original SLAC wire scanners were not optimized for speed (taking minutes to scan), and can't perform at the desired level of position…
View article: LLRF Controls Upgrade for the LCLS XTCAV project at SLAC
LLRF Controls Upgrade for the LCLS XTCAV project at SLAC Open
SLAC's Low Level Radio Frequency (LLRF) controls software for the S-Band deflecting structures needed to be upgraded significantly when a new X-Band transverse deflecting cavity (XTCAV) was installed downstream of the LCLS undulators in Sp…