Patrick Divilly
YOU?
Author Swipe
View article: The Use of a Continuous Glucose Monitoring Device in Older People
The Use of a Continuous Glucose Monitoring Device in Older People Open
Background The incidences of diabetes mellitus, dementia and frailty are individually increasing. Continuous glucose monitoring(CGM) is a wearable technology that measures interstitial glucose in real-time and avoids the need for finger pr…
View article: ASSOCIATION BETWEEN PERSON-REPORTED HYPOGLYCAEMIA AND TIME BELOW RANGE: THE HYPO-METRICS STUDY
ASSOCIATION BETWEEN PERSON-REPORTED HYPOGLYCAEMIA AND TIME BELOW RANGE: THE HYPO-METRICS STUDY Open
ASSOCIATION BETWEEN PERSON-REPORTED HYPOGLYCAEMIA AND TIME BELOW RANGE: THE HYPO-METRICS STUDY
View article: Relationship Between Sensor-Detected Hypoglycemia and Patient-Reported Hypoglycemia in People With Type 1 and Insulin-Treated Type 2 Diabetes: The Hypo-METRICS Study
Relationship Between Sensor-Detected Hypoglycemia and Patient-Reported Hypoglycemia in People With Type 1 and Insulin-Treated Type 2 Diabetes: The Hypo-METRICS Study Open
OBJECTIVE Use of continuous glucose monitoring (CGM) has led to greater detection of hypoglycemia; the clinical significance of this is not fully understood. The Hypoglycaemia–Measurement, Thresholds and Impacts (Hypo-METRICS) study was de…
View article: The relationship between sensor-detected hypoglycemia and patient-reported hypoglycemia in people with type 1 and insulin-treated type 2 diabetes: The Hypo-METRICS study
The relationship between sensor-detected hypoglycemia and patient-reported hypoglycemia in people with type 1 and insulin-treated type 2 diabetes: The Hypo-METRICS study Open
Objective: Use of continuous glucose monitoring (CGM) has led to greater detection of hypoglycemia, the clinical significance of this is not fully understood. The HypoMETRICS study was designed to investigate the rates and duration of sens…
View article: The relationship between sensor-detected hypoglycemia and patient-reported hypoglycemia in people with type 1 and insulin-treated type 2 diabetes: The Hypo-METRICS study
The relationship between sensor-detected hypoglycemia and patient-reported hypoglycemia in people with type 1 and insulin-treated type 2 diabetes: The Hypo-METRICS study Open
Objective: Use of continuous glucose monitoring (CGM) has led to greater detection of hypoglycemia, the clinical significance of this is not fully understood. The HypoMETRICS study was designed to investigate the rates and duration of sens…
View article: Associations of clinical, psychological, and sociodemographic characteristics and ecological momentary assessment completion in the 10‐week <scp>Hypo‐METRICS</scp> study: Hypoglycaemia <scp>MEasurements ThResholds</scp> and <scp>ImpaCtS</scp>
Associations of clinical, psychological, and sociodemographic characteristics and ecological momentary assessment completion in the 10‐week <span>Hypo‐METRICS</span> study: Hypoglycaemia <span>MEasurements ThResholds</span> and <span>ImpaCtS</span> Open
Introduction Reporting of hypoglycaemia and its impact in clinical studies is often retrospective and subject to recall bias. We developed the Hypo‐METRICS app to measure the daily physical, psychological, and social impact of hypoglycaemi…
View article: Associations Between Hypoglycemia Awareness Status and Symptoms of Hypoglycemia Among Adults with Type 1 or Insulin-Treated Type 2 Diabetes Using the Hypo-METRICS Smartphone Application
Associations Between Hypoglycemia Awareness Status and Symptoms of Hypoglycemia Among Adults with Type 1 or Insulin-Treated Type 2 Diabetes Using the Hypo-METRICS Smartphone Application Open
Introduction: This study examined associations between hypoglycemia awareness status and hypoglycemia symptoms reported in real-time using the novel Hypoglycaemia-MEasurement, ThResholds and ImpaCtS (Hypo-METRICS) smartphone application (a…
View article: A Comparison of the Rates of Clock-Based Nocturnal Hypoglycemia and Hypoglycemia While Asleep Among People Living with Diabetes: Findings from the Hypo-METRICS Study
A Comparison of the Rates of Clock-Based Nocturnal Hypoglycemia and Hypoglycemia While Asleep Among People Living with Diabetes: Findings from the Hypo-METRICS Study Open
Introduction: Nocturnal hypoglycemia is generally calculated between 00:00 and 06:00. However, those hours may not accurately reflect sleeping patterns and it is unknown whether this leads to bias. We therefore compared hypoglycemia rates …
View article: Assessing the Content Validity, Acceptability, and Feasibility of the Hypo-METRICS App: Survey and Interview Study
Assessing the Content Validity, Acceptability, and Feasibility of the Hypo-METRICS App: Survey and Interview Study Open
Background The Hypoglycaemia – MEasurement, ThResholds and ImpaCtS (Hypo-METRICS) smartphone app was developed to investigate the impact of hypoglycemia on daily functioning in adults with type 1 diabetes mellitus or insulin-treated type 2…
View article: Psychometric properties of an innovative smartphone application to investigate the daily impact of hypoglycemia in people with type 1 or type 2 diabetes: The Hypo-METRICS app
Psychometric properties of an innovative smartphone application to investigate the daily impact of hypoglycemia in people with type 1 or type 2 diabetes: The Hypo-METRICS app Open
Introduction The aim of this study was to determine the acceptability and psychometric properties of the Hypo-METRICS (Hypoglycemia MEasurement, ThResholds and ImpaCtS) application (app): a novel tool designed to assess the direct impact o…
View article: Assessing the Content Validity, Acceptability, and Feasibility of the Hypo-METRICS App: Survey and Interview Study (Preprint)
Assessing the Content Validity, Acceptability, and Feasibility of the Hypo-METRICS App: Survey and Interview Study (Preprint) Open
BACKGROUND The Hypoglycaemia – MEasurement, ThResholds and ImpaCtS (Hypo-METRICS) smartphone app was developed to investigate the impact of hypoglycemia on daily functioning in adults with type 1 diabetes mellitus or insulin-treated type …
View article: Hypo‐METRICS: Hypoglycaemia—MEasurement, ThResholds and ImpaCtS—A multi‐country clinical study to define the optimal threshold and duration of sensor‐detected hypoglycaemia that impact the experience of hypoglycaemia, quality of life and health economic outcomes: The study protocol
Hypo‐METRICS: Hypoglycaemia—MEasurement, ThResholds and ImpaCtS—A multi‐country clinical study to define the optimal threshold and duration of sensor‐detected hypoglycaemia that impact the experience of hypoglycaemia, quality of life and health economic outcomes: The study protocol Open
Introduction Hypoglycaemia is a significant burden to people living with diabetes and an impediment to achieving optimal glycaemic outcomes. The use of continuous glucose monitoring (CGM) has improved the capacity to assess duration and le…
View article: NOVEL VISUAL TOOL TO ASSESS THE PREVALENCE OF HYPOGLYCAEMIA SYMPTOMS IN TYPE 1 DIABETES
NOVEL VISUAL TOOL TO ASSESS THE PREVALENCE OF HYPOGLYCAEMIA SYMPTOMS IN TYPE 1 DIABETES Open
International audience
View article: Investigating the day-to-day impact of hypoglycaemia in adults with type 1 or type 2 diabetes: design and validation protocol of the Hypo-METRICS application
Investigating the day-to-day impact of hypoglycaemia in adults with type 1 or type 2 diabetes: design and validation protocol of the Hypo-METRICS application Open
Introduction Hypoglycaemia is a frequent adverse event and major barrier for achieving optimal blood glucose levels in people with type 1 or type 2 diabetes using insulin. The Hypo-RESOLVE (Hypoglycaemia—Redefining SOLutions for better liV…
View article: Primary hyperparathyroidism and Zollinger Ellison syndrome during pregnancy: a case report
Primary hyperparathyroidism and Zollinger Ellison syndrome during pregnancy: a case report Open
Summary Multiple endocrine neoplasia type 1 (MEN1) is a rare inherited endocrine disorder with a high rate of penetrance. The incidence of MEN1 is 1/30,000 in the general population; however, it is quite rare for a patient to present for m…