R. Mehdiyev
YOU?
Author Swipe
View article: Precision measurement of the specific activity of $$^{39}$$Ar in atmospheric argon with the DEAP-3600 detector
Precision measurement of the specific activity of $$^{39}$$Ar in atmospheric argon with the DEAP-3600 detector Open
The specific activity of the $$\beta $$ decay of $$^{39}$$ Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 ± 24) kg of liquid argon distilled from …
View article: Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector
Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector Open
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosp…
View article: Electromagnetic backgrounds and potassium-42 activity in the DEAP-3600 dark matter detector
Electromagnetic backgrounds and potassium-42 activity in the DEAP-3600 dark matter detector Open
The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne\nsingle phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB.\nThe experimental signature of dark matter interactions is keV-scale $^{40}$Ar\nnucl…
View article: Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB
Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB Open
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter\nexperiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The\ndetector consists of 3279 kg of LAr contained in a spherical acrylic vessel.\nThis paper …
View article: Search for Sterile Neutrinos in MINOS and MINOS+ Using a Two-Detector Fit
Search for Sterile Neutrinos in MINOS and MINOS+ Using a Two-Detector Fit Open
A search for mixing between active neutrinos and light sterile neutrinos has been performed by looking for muon neutrino disappearance in two detectors at baselines of 1.04 and 735 km, using a combined MINOS and MINOS+ exposure of 16.36×10…
View article: First Results from the DEAP-3600 Dark Matter Search with Argon at SNOLAB
First Results from the DEAP-3600 Dark Matter Search with Argon at SNOLAB Open
This Letter reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with…
View article: First observation of low energy electron neutrinos in a liquid argon time projection chamber
First observation of low energy electron neutrinos in a liquid argon time projection chamber Open
The capabilities of liquid argon time projection chambers (LArTPCs) to\nreconstruct the spatial and calorimetric information of neutrino events have\nmade them the detectors of choice in a number of experiments, specifically\nthose looking…
View article: Constraints on large extra dimensions from the MINOS experiment
Constraints on large extra dimensions from the MINOS experiment Open
We report new constraints on the size of large extra dimensions from data collected by the MINOS experiment between 2005 and 2012. Our analysis employs a model in which sterile neutrinos arise as Kaluza-Klein states in large extra dimensio…
View article: Search for Sterile Neutrinos Mixing with Muon Neutrinos in MINOS
Search for Sterile Neutrinos Mixing with Muon Neutrinos in MINOS Open
We report results of a search for oscillations involving a light sterile neutrino over distances of 1.04 and 735 km in a ν_{μ}-dominated beam with a peak energy of 3 GeV. The data, from an exposure of 10.56×10^{20} protons on target, are a…
View article: Search for time-independent Lorentz violation using muon neutrino to muon antineutrino transitions in MINOS
Search for time-independent Lorentz violation using muon neutrino to muon antineutrino transitions in MINOS Open
Data from the MINOS experiment has been used to search for mixing between muon neutrinos and muon antineutrinos using a time-independent Lorentz-violating formalism derived from the Standard-Model Extension (SME). MINOS is uniquely capable…
View article: Search for time-independent Lorentz violation using muon neutrino to\n muon antineutrino transitions in MINOS
Search for time-independent Lorentz violation using muon neutrino to\n muon antineutrino transitions in MINOS Open
Data from the MINOS experiment has been used to search for mixing between\nmuon neutrinos and muon antineutrinos using a time-independent\nLorentz-violating formalism derived from the Standard-Model Extension (SME).\nMINOS is uniquely capa…
View article: A Time Projection Chamber with GEM-Based Readout
A Time Projection Chamber with GEM-Based Readout Open
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, resu…
View article: Measurement of the multiple-muon charge ratio in the MINOS Far Detector
Measurement of the multiple-muon charge ratio in the MINOS Far Detector Open
The charge ratio, Rμ=Nμ+/Nμ−, for cosmogenic multiple-muon events observed at an underground depth of 2070 mwe has been measured using the magnetized MINOS Far Detector. The multiple-muon events, recorded nearly continuously from August 20…