Lars Sennerby
YOU?
Author Swipe
View article: Osteotome‐Induced Blood Clot and Subsequent Bone Formation with the Use of Collagen Sponge for Integration of Single Dental Implants into the Atrophied Posterior Maxilla: A Retrospective Follow‐Up of 36 Implants after 5 to 13 years
Osteotome‐Induced Blood Clot and Subsequent Bone Formation with the Use of Collagen Sponge for Integration of Single Dental Implants into the Atrophied Posterior Maxilla: A Retrospective Follow‐Up of 36 Implants after 5 to 13 years Open
Background . Atrophy of the posterior maxilla as a consequence of tooth loss and sinus pneumatization is a frequent condition encountered in the clinical practice. Prosthetic rehabilitation with implants in these patients often requires so…
View article: A five‐year retrospective follow‐up study of tapered hydrophilic implants placed with or without GBR procedures
A five‐year retrospective follow‐up study of tapered hydrophilic implants placed with or without GBR procedures Open
Background: Preserving the peri-implant bone level is key for the longevity of an implant-supported prosthesis. Experimental studies have shown tapering to improve primary implant stability, especially in soft bone densities. In cases with…
View article: A retrospective case series report on a novel aggressively threaded and tapered implant
A retrospective case series report on a novel aggressively threaded and tapered implant Open
Background: Firm primary implant stability is considered as one determinant of success with implant therapy. A novel tapered implant with aggressive threading aiming at high primary stability, also in low bone densities, using a simplified…
View article: Primary stability of three different aggressively threaded and tapered implants in low‐density polyurethane
Primary stability of three different aggressively threaded and tapered implants in low‐density polyurethane Open
Background: Firm primary implant stability is one factor of importance to achieve osseointegration and predictable clinical outcomes with dental implant therapy. A common perception among dental implant users is that aggressively threaded …
View article: Current literature review on methods for measuring the stability of osseointegrable implants.
Current literature review on methods for measuring the stability of osseointegrable implants. Open
“Osseointegration” as formulated by Alberktson is crucial for implant survival and success. Osseointegration is a measure of implant stability. Measuring implant stability helps to arrive at decisions as to loading of an implant, allows ch…
View article: Factors influencing marginal bone loss at a hydrophilic implant design placed with or without GBR procedures: A 5‐year retrospective study
Factors influencing marginal bone loss at a hydrophilic implant design placed with or without GBR procedures: A 5‐year retrospective study Open
Background Preserving the peri-implant bone level is key for the longevity of an implant-supported prosthesis. In cases with non-optimal bone conditions, guided bone regeneration (GBR) procedures may be applied which might challenge the lo…
View article: Is Peri-Implant Probing Causing Over-Diagnosis and Over-Treatment of Dental Implants?
Is Peri-Implant Probing Causing Over-Diagnosis and Over-Treatment of Dental Implants? Open
Pocket probing depth (PPD) and bleeding on probing (BOP) measurements are useful indices for the assessment of periodontal conditions. The same periodontal indices are commonly recommended to evaluate the dental implant/tissue interface to…
View article: Extraction of Remaining Teeth and Same Day Loading of Neoss Proactive Dental Implants with a Full-arch Fixed Provisional Bridge. A Survival Analysis
Extraction of Remaining Teeth and Same Day Loading of Neoss Proactive Dental Implants with a Full-arch Fixed Provisional Bridge. A Survival Analysis Open
Removal of remaining teeth and same day loading of an implant-supported full-arch bridge may be a sensible treatment modality for many patients presenting with a severely diseased partial dentition.The aim of the present study was to retro…
View article: Immediate Function of 3.25 mm Diameter Implants in Aesthetic Regions. An 18-month Clinical, Radiographic and Resonance Frequency Analysis (RFA) Study
Immediate Function of 3.25 mm Diameter Implants in Aesthetic Regions. An 18-month Clinical, Radiographic and Resonance Frequency Analysis (RFA) Study Open
The aim of the study was to evaluate the use of narrow implants (3.25 mm) to replace upper lateral and lower incisors according to an established immediate function protocol.A total of 49 narrow implants (Neoss Proactive 3.25 mm implants, …
View article: 5-year Results of Neoss Dental Implants Restored at Implant-Level. A Retrospective Follow-Up Study
5-year Results of Neoss Dental Implants Restored at Implant-Level. A Retrospective Follow-Up Study Open
One way of reducing the cost for screw-retained implant-supported dental prosthesis is to avoid the use of prosthetic abutments.However, concerns have been raised that this might lead to complications such as extensive marginal bone loss r…
View article: Factors Influencing Resonance Frequency Analysis (RFA) Measurements and 5-Year Survival of Neoss Dental Implants
Factors Influencing Resonance Frequency Analysis (RFA) Measurements and 5-Year Survival of Neoss Dental Implants Open
Background . Diagnostic instruments based on resonance frequency analysis (RFA) can be utilised to assess dental implant stability during treatment and follow-up. Aim . The aim of the present study was to investigate the influence of patie…
View article: A One-year Follow-up Study of a Tapered Hydrophilic Implant Design Using Various Placement Protocols in the Maxilla
A One-year Follow-up Study of a Tapered Hydrophilic Implant Design Using Various Placement Protocols in the Maxilla Open
Purpose: To study the clinical/radiographic outcomes and stability of a tapered implant design with a hydrophilic surface when placed in the maxilla using various protocols and followed for one year. Methods: Ninety-seven consecutive patie…
View article: A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded
A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded Open
Background . Hydrophilic and moderately rough implant surfaces have been proposed to enhance the osseointegration response. Aim . The aim of this study was to compare early changes of stability for two implants with identical macrodesign b…