Pere J. Riu
YOU?
Author Swipe
View article: Minimally-invasive electrical impedance spectroscopy in lung tissue: present and future trends
Minimally-invasive electrical impedance spectroscopy in lung tissue: present and future trends Open
Electrical impedance measurements performed in-vivo and in-situ in lung tissue so far have focused on detecting different pathologies, including neoplasm. Once its ability for this has been established, the authors intend to investigate wh…
View article: Machine learning allows robust classification of lung neoplasm tissue using an electronic biopsy through minimally-invasive electrical impedance spectroscopy
Machine learning allows robust classification of lung neoplasm tissue using an electronic biopsy through minimally-invasive electrical impedance spectroscopy Open
View article: Involvement of the Lung Parenchyma Analyzed by Frequency Components of the Tidal Volume Assessed by Electrical Bioimpedance
Involvement of the Lung Parenchyma Analyzed by Frequency Components of the Tidal Volume Assessed by Electrical Bioimpedance Open
Pulmonary function tests are vital for detecting pathologies, especially chronic obstructive pulmonary diseases (COPD), emphasizing the importance of assessing lung parenchyma involvement in maintaining proper gas exchange. Electrical impe…
View article: Relaxation differences using EIS through bronchoscopy of healthy and pathological lung tissue
Relaxation differences using EIS through bronchoscopy of healthy and pathological lung tissue Open
The use of electrical impedance spectroscopy for lung tissue differentiation is an opportunity for the improvement of clinical diagnosis. The aim of this work is to distinguish among different lung tissue states by evaluating the differenc…
View article: Differentiation using minimally-invasive bioimpedance measurements of healthy and pathological lung tissue through bronchoscopy
Differentiation using minimally-invasive bioimpedance measurements of healthy and pathological lung tissue through bronchoscopy Open
Purpose To use minimally-invasive transcatheter electrical impedance spectroscopy measurements for tissue differentiation among healthy lung tissue and pathologic lung tissue from patients with different respiratory diseases (neoplasm, fib…
View article: Electrical Impedance Tomography to Measure Spirometry Parameters in Chronic Obstructive Pulmonary Disease Patients
Electrical Impedance Tomography to Measure Spirometry Parameters in Chronic Obstructive Pulmonary Disease Patients Open
Spirometry is a test for the diagnosis of chronic obstructive pulmonary disease. It is a technique that can be intolerant due to the essential use of a mouthpiece and a clamp. This study proposes the use of electrical impedance tomography …
View article: Effect of Calibration for Tissue Differentiation Between Healthy and Neoplasm Lung Using Minimally Invasive Electrical Impedance Spectroscopy
Effect of Calibration for Tissue Differentiation Between Healthy and Neoplasm Lung Using Minimally Invasive Electrical Impedance Spectroscopy Open
his study proposes a calibration method and analyses the effect of this calibration in lung measures, using minimally invasive electrical impedance spectroscopy with the 3-electrode method, for tissue differentiation between healthy and ne…
View article: Minimally Invasive Lung Tissue Differentiation Using Electrical Impedance Spectroscopy: A Comparison of the 3- and 4-Electrode Methods
Minimally Invasive Lung Tissue Differentiation Using Electrical Impedance Spectroscopy: A Comparison of the 3- and 4-Electrode Methods Open
Altres ajuts: Secretariat d'Universitats i Recerca, Generalitat de Catalunya; the European Social Fund.
View article: Minimally Invasive Real-Time Electrical Impedance Spectroscopy Diagnostic Tool for Lung Parenchyma Pathologies
Minimally Invasive Real-Time Electrical Impedance Spectroscopy Diagnostic Tool for Lung Parenchyma Pathologies Open
Electrical Impedance Spectroscopy has already demonstrated the ability to distinguish different tissues types, or tumors from normal tissue, or tissues displaying diverse degrees of pathology. When applying the technique, however, the nece…
View article: Numerical Assessment in Aeronautics for Electromagnetic Environmental Effects
Numerical Assessment in Aeronautics for Electromagnetic Environmental Effects Open
Electrical and electronic systems on board air vehicles are susceptible to electromagnetic interference (EMI). This has made the topic of electromagnetic compatibility (EMC), a major concern for aircraft safety. The use of composite materi…
View article: SIVA UAV: A Case Study for the EMC Analysis of Composite Air Vehicles
SIVA UAV: A Case Study for the EMC Analysis of Composite Air Vehicles Open
The increased use of carbon-fiber composites in unmanned aerial vehicles is a challenge for their EMC assessment
\nby numerical solvers. For accurate and reliable simulations, numerical procedures should be tested not only for individual c…
View article: Book review of “Biomagnetics: Principles and Applications of Biomagnetic Stimulation and Imaging” edited by Shoogo Ueno and Masaki Sekino
Book review of “Biomagnetics: Principles and Applications of Biomagnetic Stimulation and Imaging” edited by Shoogo Ueno and Masaki Sekino Open
This article is a review of the book “Biomagnetics: Principles and Applications of Biomagnetic Stimulation and Imaging” (ISBN 978-1-4822-3920-1, 343 pages) edited by Shoogo Ueno and Masaki Sekino published by CRC Press, Taylor and Francis …