Shaik Mullapathi Farooq
YOU?
Author Swipe
View article: An Investigation on Physico- Chemical Parameters of Ground Water Near Mining Areas of Kadapa District, A. P, India.
An Investigation on Physico- Chemical Parameters of Ground Water Near Mining Areas of Kadapa District, A. P, India. Open
Due to the tremendous increases in population, industrialization, and human activity, water is highly polluted with various harmful elements. The good quality availability of water for human consumption is very important for preventing wat…
View article: An Effective Security Scheme for Attacks on Sample Value Messages in IEC 61850 Automated Substations
An Effective Security Scheme for Attacks on Sample Value Messages in IEC 61850 Automated Substations Open
The trend of transforming substations into smart automated facilities has led to their swift digitalization and automation. To facilitate data exchange among equipment within these substations, the IEC 61850 standard has become the predomi…
View article: Referee report. For: Modified recurrent equation-based cubic spline interpolation for missing data recovery in phasor measurement unit (PMU) [version 1; peer review: 1 approved with reservations, 1 not approved]
Referee report. For: Modified recurrent equation-based cubic spline interpolation for missing data recovery in phasor measurement unit (PMU) [version 1; peer review: 1 approved with reservations, 1 not approved] Open
View article: Implementing Secure Routable GOOSE and SV Messages Based on IEC 61850-90-5
Implementing Secure Routable GOOSE and SV Messages Based on IEC 61850-90-5 Open
Next generation power systems are active networks that handle two-way power flow. They are equipped with extensive communication capabilities to perform dynamic monitoring, protection and control operations. Synchrophasors provide a pseudo…
View article: Using ID-Based Authentication and Key Agreement Mechanism for Securing Communication in Advanced Metering Infrastructure
Using ID-Based Authentication and Key Agreement Mechanism for Securing Communication in Advanced Metering Infrastructure Open
Smart metering technology plays a key role in Advanced Metering Infrastructure (AMI) in Smart Grid (SG). Smart Meters (SM) measure Power Consumption Data (PCD) of household devices and send it to DSO (Distributed System Operator) for furth…
View article: S-GoSV: Framework for Generating Secure IEC 61850 GOOSE and Sample Value Messages
S-GoSV: Framework for Generating Secure IEC 61850 GOOSE and Sample Value Messages Open
Standardized communication plays an important role in substation automation system (SAS). IEC 61850 is a de-facto standard in SAS. It facilitates smooth communication between different devices located in the substation by achieving interop…
View article: Certificate Based Security Mechanisms in Vehicular Ad-Hoc Networks based on IEC 61850 and IEEE WAVE Standards
Certificate Based Security Mechanisms in Vehicular Ad-Hoc Networks based on IEC 61850 and IEEE WAVE Standards Open
When equipped with an on-board wireless kit, electric vehicles (EVs) can communicate with nearby entities, e.g., road side units (RSUs), via a vehicle ad-hoc network (VANET). More observability enables smart charging algorithms where charg…
View article: A Novel Approach for Mitigation of Replay and Masquerade Attacks in Smartgrids Using IEC 61850 Standard
A Novel Approach for Mitigation of Replay and Masquerade Attacks in Smartgrids Using IEC 61850 Standard Open
There is growing awareness towards cybersecurity threats in power systems. Deployment of more intelligent electronic devices (IEDs) and the communication lines increase the probability of such attacks. IEC 61850 standard facilitates commun…
View article: Analysis and Implementation of Message Authentication Code (MAC) Algorithms for GOOSE Message Security
Analysis and Implementation of Message Authentication Code (MAC) Algorithms for GOOSE Message Security Open
There is growing awareness towards cybersecurity threats in power systems. IEC 61850 standard facilitates communication between different Intelligent Electronic devices (IEDs) and eases interoperable operation with set data and message str…
View article: Performance Evaluation and Analysis of IEC 62351-6 Probabilistic Signature Scheme for Securing GOOSE Messages
Performance Evaluation and Analysis of IEC 62351-6 Probabilistic Signature Scheme for Securing GOOSE Messages Open
Cyber security is a growing concern in power systems. To achieve security requirements such as authentication and integrity for generic object-oriented substation event (GOOSE) messages, IEC 62351-6 standard recommends using digital signat…
View article: Certificate Based Authentication Mechanism for PMU Communication Networks Based on IEC 61850-90-5
Certificate Based Authentication Mechanism for PMU Communication Networks Based on IEC 61850-90-5 Open
Smart grids are becoming increasingly popular thanks to their ability to operate with higher precision and smaller margins. Dynamic operation control in smart grids can be achieved with phasor measurement unit (PMU) based wide area monitor…