View article: Conceptual design of a wide band gap based cryogenically cooled MW-class inverter
Conceptual design of a wide band gap based cryogenically cooled MW-class inverter Open
The increasing need for higher power density and closer integration of power subsystems consisting of superconducting motors/generators, degaussing coils, energy storage modules, and cables leads one to consider the merits of refrigerating…
View article: Design of self-centering support system for 1.5 T MRI cryostat
Design of self-centering support system for 1.5 T MRI cryostat Open
View article: Indirect estimation of helium pressure at cryogenic temperatures
Indirect estimation of helium pressure at cryogenic temperatures Open
To enhance robustness of automated Temperature vs parametertype of measurements in a cold exchange gas based sampletemperature control system, a second control loop is being addedto compensate for pressure variations. For this purpose, a m…
View article: Multiphysics analysis of operational stresses in a 1.5 T MRI magnet
Multiphysics analysis of operational stresses in a 1.5 T MRI magnet Open
View article: Helium Re-condenser for 1.5T Zero-Boil-Off (ZBO) MRI cryostat
Helium Re-condenser for 1.5T Zero-Boil-Off (ZBO) MRI cryostat Open
Superconducting MRI magnet is the most exhaustive commercial application of superconductivity and helium cryogenics. Cryocooler based Zero-Boil-Off (ZBO) technique is inevitable for the present-day scanner. An MRI cryostat for a 1.5T MRI m…
View article: Semiconductor to metal transition for Ni doped CdO thin films
Semiconductor to metal transition for Ni doped CdO thin films Open
In the present investigation resistivity Vs temperature measurements have been performed for solgel prepared pure and Ni doped CdO (NDO) thin films. The semiconducting behavior i.e. negative temperature coefficient of resistivity (TCR) of …
View article: Development of high homogeneity and high stability 1.5T superconducting magnet for whole body MRI scanner
Development of high homogeneity and high stability 1.5T superconducting magnet for whole body MRI scanner Open
A multi-coil actively shielded 1.5T superconducting magnet has been designed for a whole-body MRI clinical scanner. The magnet has six primary coils and two active shield coils that have a reverse polarity of current with respect to the pr…
View article: Post-Quench electromechanical analysis of 1.5 T whole body clinical MRI system
Post-Quench electromechanical analysis of 1.5 T whole body clinical MRI system Open
A 1.5 T superconducting magnet has been designed for the whole-body clinical MRI scanner. The stored energy (∼4.5 MJ) of the magnet if released during a quench, can adversely affect the coil by raising its temperature and the associated vo…
View article: Analysis of mechanical stress due to winding pretension in a 1.5 T superconducting MRI magnet
Analysis of mechanical stress due to winding pretension in a 1.5 T superconducting MRI magnet Open
The paper presents the analysis of stresses due to winding tension in a 1.5 T MRI magnet with a clear bore of ∼1 m and an outer diameter of ∼1.8 m. The magnet has four pairs of symmetric coils arranged over a length of ∼1.5 m. The stringen…
View article: Design of an RMS based Steady State Detector for a Cryogenic Temperature Control Process and Automation of Temperature vs Material Property Characterizations
Design of an RMS based Steady State Detector for a Cryogenic Temperature Control Process and Automation of Temperature vs Material Property Characterizations Open
Characterization studies of material properties as a function of temperature, eg. studies of temperature dependence of resistivity, hall effect or resistance are regularly carried out in material research laboratories. In these measurement…
View article: Stress analysis of cryogenic suspension system of superconducting MRI magnet cryostat
Stress analysis of cryogenic suspension system of superconducting MRI magnet cryostat Open
View article: Control and materials characterization System for 6T Superconducting Cryogen Free Magnet Facility at IUAC, New Delhi
Control and materials characterization System for 6T Superconducting Cryogen Free Magnet Facility at IUAC, New Delhi Open
A system for carrying out automatic experimental measurements of various electrical transport characteristics and their relation to magnetic fields for samples mounted on the sample holder on a Variable Temperature Insert (VTI) of the Cryo…
View article: Helium exchange gas based variable temperature insert for cryogen-free magnet system
Helium exchange gas based variable temperature insert for cryogen-free magnet system Open
A cryocooler based variable temperature inserts (VTI) has been designed and developed for measurement of physical properties at low temperature and high magnetic field. The VTI, designed using the helium exchange gas principle, needs to be…
View article: Feasibility study of parallel conduction cooling of NbTi magnet and sample probe in a cryogen-free magnet system
Feasibility study of parallel conduction cooling of NbTi magnet and sample probe in a cryogen-free magnet system Open
The conduction cooling of both a 6 T superconducting magnet along with a sample probe in a parallel configuration is addressed in this work. A Gifford-McMahon (GM) cryocooler is directly cooling the NbTi magnet, which aims to be kept at 4 …
View article: Experimental load map of two stage 1.5 W at 4.2 K (SRDK-415D) GM cryocooler
Experimental load map of two stage 1.5 W at 4.2 K (SRDK-415D) GM cryocooler Open
Two stage GM cryocooler is one of the major components for development of any conduction cooled superconducting magnet system. Recently, IUAC New Delhi has developed a 6T conduction cooled NbTi magnet system using a two stage GM cryocooler…
View article: Theoretical analysis and experimental investigation on performance of the thermal shield of accelerator cryomodules by thermo-siphon cooling of liquid nitrogen
Theoretical analysis and experimental investigation on performance of the thermal shield of accelerator cryomodules by thermo-siphon cooling of liquid nitrogen Open
Five beam line cryomodules with total 27 superconducting Radio Frequency (RF) cavities are installed and commissioned at IUAC to enhance the energy of heavy ion from 15 UD Pelletron. To reduce the heat load at 4.2 K, liquid nitrogen (LN2) …
View article: Quench characteristics of 6 T conduction-cooled NbTi magnet system
Quench characteristics of 6 T conduction-cooled NbTi magnet system Open
Conduction-cooled superconducting magnets are cooled by cryocooler alone through the conductive thermal links. The limited refrigeration capacity and conductive cooling make the magnets more prone to quench. We have studied the quench char…
View article: Gas gap heat switch for a cryogen-free magnet system
Gas gap heat switch for a cryogen-free magnet system Open
Cryogen-free superconducting magnet systems (CFMS) have become popular over the last two decades for the simple reason that the use of liquid helium is rather cumbersome and that helium is a scarce resource. Some available CFMS use a mecha…
View article: Commissioning of the new 1kw class refrigerator for superconducting LINAC at IUAC
Commissioning of the new 1kw class refrigerator for superconducting LINAC at IUAC Open
For the LINAC booster project 5 cryostats with 27 resonators have been commissioned in phases. The total measured heat load on cryostats and distribution system together is 350 W at 4.4 K. At present total heat load is managed by the 15 ye…
View article: Cool Down Analysis of a Cryocooler Based Quadrupole Magnet Cryostat
Cool Down Analysis of a Cryocooler Based Quadrupole Magnet Cryostat Open
A superconducting quadrupole doublet magnet with cold superferric iron cover for the Hybrid Recoil Mass Analyzer (HYRA) beam line has been commissioned. The total cold mass of the helium vessel with iron yoke and pole is 2 ton. A set of tw…
View article: Final Commissioning of the Superconducting Heavy Ion Linear Accelerator at IUAC, Delhi
Final Commissioning of the Superconducting Heavy Ion Linear Accelerator at IUAC, Delhi Open
The superconducting linac as a booster of the 15UD Pelletron accelerator was partly commissioned with one linac module housing eight quarter wave bulk niobium cavities along with the superbuncher and rebuncher cryomodules. Subsequently two…