Ton G. van Leeuwen
YOU?
Author Swipe
View article: Ex Vivo Optical Coherence Tomography Analysis of Resected Human Bladder with a Forward-Looking Microelectromechanical Systems Mirror-Based Catheter
Ex Vivo Optical Coherence Tomography Analysis of Resected Human Bladder with a Forward-Looking Microelectromechanical Systems Mirror-Based Catheter Open
A technique that enables real-time diagnosis of bladder cancer is needed. Optical coherence tomography (OCT) is a promising technique, but a forward-looking OCT catheter is necessary for OCT to enable bladder cancer diagnosis. This study a…
View article: Nerve Fibres in Psoriatic Skin and Their Relation to Vasculature and Clinical Parameters
Nerve Fibres in Psoriatic Skin and Their Relation to Vasculature and Clinical Parameters Open
Emerging evidence supports the neurogenic origin of psoriasis, yet the morphology and distribution of nerve fibres in psoriatic skin remain poorly characterised due to methodological inconsistencies and limited 3D data. The aim of this stu…
View article: Identification of Ischemic Stroke Patients Based on Plasma Concentrations of Extracellular Vesicles
Identification of Ischemic Stroke Patients Based on Plasma Concentrations of Extracellular Vesicles Open
Patients presenting with stroke symptoms suffer from either ischemic stroke, hemorrhagic stroke, transient ischemic attacks (TIA), or “stroke mimics,” which include benign headaches, epilepsy, and vestibular disorders. As ischemic and hemo…
View article: Targeting Oncofoetal Chondroitin Sulphate Allows Identification of Tumour‐Derived Extracellular Vesicles
Targeting Oncofoetal Chondroitin Sulphate Allows Identification of Tumour‐Derived Extracellular Vesicles Open
Tumour‐derived extracellular vesicles (tdEVs) are widely studied for their contribution to tumour progression and metastasis. These studies are hampered by the lack of specific markers to identify the tdEVs. Here, we show that oncofoetal c…
View article: Perspective on the use of optics in bladder cancer detection and diagnosis
Perspective on the use of optics in bladder cancer detection and diagnosis Open
Optical techniques could accelerate BC diagnosis, reduce costs, and enable alternative treatments. However, overcoming technical and practical challenges is essential for their successful integration.
View article: Achieving High‐Precision Attenuation Coefficient Measurement in Optical Coherence Tomography
Achieving High‐Precision Attenuation Coefficient Measurement in Optical Coherence Tomography Open
In this study, we aim to validate the analytical Cramer‐Rao lower bound (CRLB) equation for determining attenuation coefficients using a 1310 nm Optical Coherence Tomography (OCT) system. Our experimental results successfully confirm the v…
View article: Pulse Oximetry: 50 Years of Inventions & Discoveries in Biomedical Optics
Pulse Oximetry: 50 Years of Inventions & Discoveries in Biomedical Optics Open
The editorial introduces the JBO Special Issue on Pulse Oximetry.
View article: Contrast-enhanced Ultrasound Imaging Following Transperineal Laser Ablation for Lower Urinary Tract Symptoms
Contrast-enhanced Ultrasound Imaging Following Transperineal Laser Ablation for Lower Urinary Tract Symptoms Open
This study described ablation zone shape and measured the ablation volume following TPLA by various fiber configurations using CEUS, and compared these to functional outcomes. Prostate volume reduced significantly during follow-up. Segment…
View article: All-reflective tethered capsule endoscope for multimodal optical coherence tomography in the esophagus
All-reflective tethered capsule endoscope for multimodal optical coherence tomography in the esophagus Open
An all-reflective TCE is feasible and allows for achromatic high-quality imaging. Such a device could be utilized as a platform for testing various combinations of modalities to identify the optimal candidates without requiring design iter…
View article: Model for the diffuse reflectance in spatial frequency domain imaging (Erratum)
Model for the diffuse reflectance in spatial frequency domain imaging (Erratum) Open
[This corrects the article DOI: 10.1117/1.JBO.28.4.046002.].
View article: Subminute thermal damage to cell types present in the skin
Subminute thermal damage to cell types present in the skin Open
The results imply that there is a cell-type-dependent sensitivity to thermal damage which suggests that neuronal cells and keratinocytes are particularly susceptible to diffusing heat from laser treatment. Damage to these cells may aid in …
View article: Towards non‐invasive tissue hydration measurements with optical coherence tomography
Towards non‐invasive tissue hydration measurements with optical coherence tomography Open
The attenuation coefficient () measured by optical coherence tomography (OCT) has been used to determine tissue hydration. Previous dual‐wavelength OCT systems could not attain the needed precision, which we attribute to the absence of wav…
View article: The impact of temperature on vascular function in connection with vascular laser treatment
The impact of temperature on vascular function in connection with vascular laser treatment Open
Pulsed dye lasers are used effectively in the treatment of psoriasis with long remission time and limited side effects. It is, however, not completely understood which biological processes underlie its favorable outcome. Pulsed dye laser t…
View article: Poloxamer-188 as a wetting agent for microfluidic resistive pulse sensing measurements of extracellular vesicles
Poloxamer-188 as a wetting agent for microfluidic resistive pulse sensing measurements of extracellular vesicles Open
Introduction Microfluidic resistive pulse sensing (MRPS) can determine the concentration and size distribution of extracellular vesicles (EVs) by measuring the electrical resistance of single EVs passing through a pore. To ensure that the …
View article: Modeling pulsed dye laser treatment of psoriatic plaques by combining numerical methods and image‐derived lesion morphologies
Modeling pulsed dye laser treatment of psoriatic plaques by combining numerical methods and image‐derived lesion morphologies Open
Objectives Knowledge of the physical effects of pulsed dye laser (PDL) treatment of psoriatic lesions is essential in unraveling the remedial mechanisms of this treatment and hence also in maximizing in its disease‐modifying potential. The…
View article: Optical feedback for real-time monitoring during transperineal laser ablation: Towards accurate treatment planning
Optical feedback for real-time monitoring during transperineal laser ablation: Towards accurate treatment planning Open
View article: Accuracy and precision of depth-resolved estimation of attenuation coefficients in optical coherence tomography
Accuracy and precision of depth-resolved estimation of attenuation coefficients in optical coherence tomography Open
We derived and validated expressions for the accuracy and precision of DRE of . A commonly used simplification of this method is not recommended as being used for OCT-attenuation reconstruction. We give a rule of thumb providing guidance i…
View article: Preventing swarm detection in extracellular vesicle flow cytometry: a clinically applicable procedure
Preventing swarm detection in extracellular vesicle flow cytometry: a clinically applicable procedure Open
To prevent swarm detection in a series of clinical samples, the measurement count rate of a single diluted plasma sample can be used to determine the optimal dilution factor. For our samples, flow cytometer, and settings, the optimal dilut…
View article: Model for the diffuse reflectance in spatial frequency domain imaging
Model for the diffuse reflectance in spatial frequency domain imaging Open
For the diffuse reflectance in SFDI, the model based on the PCBC provides more accurate results than the currently used model by Cuccia et al.
View article: A compendium of single extracellular vesicle flow cytometry
A compendium of single extracellular vesicle flow cytometry Open
Flow cytometry (FCM) offers a multiparametric technology capable of characterizing single extracellular vesicles (EVs). However, most flow cytometers are designed to detect cells, which are larger than EVs. Whereas cells exceed the backgro…
View article: Calibration procedure for enhanced mirror artifact removal in full-range optical coherence tomography using passive quadrature demultiplexing
Calibration procedure for enhanced mirror artifact removal in full-range optical coherence tomography using passive quadrature demultiplexing Open
The proposed method is simple to implement and produces high mirror artifact extinction. This may encourage the adoption of FR-OCT in clinical and industrial systems or loosen the performance requirements on the optical demodulation circui…
View article: Comparison of preprocessing techniques to reduce nontissue-related variations in hyperspectral reflectance imaging
Comparison of preprocessing techniques to reduce nontissue-related variations in hyperspectral reflectance imaging Open
Preprocessing reduces the overlap due to glare and distance variations. In general, the algorithms standard normal variate, min-max, area under the curve, and single wavelength normalization are the most suitable to preprocess data used to…
View article: Opportunities and pitfalls in (sub)diffuse reflectance spectroscopy
Opportunities and pitfalls in (sub)diffuse reflectance spectroscopy Open
For a long time, steady-state reflectance spectroscopy measurements have been performed so that diffusion theory could be used to extract tissue optical properties from the reflectance. The development of subdiffuse techniques, such as Sin…
View article: Precision of attenuation coefficient measurements by optical coherence tomography
Precision of attenuation coefficient measurements by optical coherence tomography Open
Our analytical solution provides a fast, rigorous, and easy-to-use measure for OCT-derived attenuation coefficients for signals above 20 dB. The effect of uncertainties in the focal point position on the precision in the attenuation coeffi…
View article: Quantitative Fluorescence Imaging of Perfusion—An Algorithm to Predict Anastomotic Leakage
Quantitative Fluorescence Imaging of Perfusion—An Algorithm to Predict Anastomotic Leakage Open
This study tests fluorescence imaging-derived quantitative parameters for perfusion evaluation of the gastric tube during surgery and correlates these parameters with patient outcomes in terms of anastomotic leakage. Poor fundus perfusion …
View article: Misinterpretation of solid sphere equivalent refractive index measurements and smallest detectable diameters of extracellular vesicles by flow cytometry
Misinterpretation of solid sphere equivalent refractive index measurements and smallest detectable diameters of extracellular vesicles by flow cytometry Open
Flow cytometers are utilized to characterize single submicrometer particles in biofluids, such as extracellular vesicles (EVs) and viruses.However, because calibration of the optical signals measured by flow cytometers requires optical mod…
View article: EDTA stabilizes the concentration of platelet-derived extracellular vesicles during blood collection and handling
EDTA stabilizes the concentration of platelet-derived extracellular vesicles during blood collection and handling Open
Citrate is the recommended anticoagulant for studies on plasma extracellular vesicles (EVs). Because citrate incompletely blocks platelet activation and the release of platelet-derived EVs, we compared EDTA and citrate in that regard. Bloo…
View article: Correction to: A literature review and novel theoretical approach on the optical properties of whole blood
Correction to: A literature review and novel theoretical approach on the optical properties of whole blood Open
View article: MP46-07 PRELIMINARY RESULTS OF IN VIVO FOCAL TRANSPERINEAL LASER ABLATION TREATMENT OF THE PROSTATE: CORRELATION OF mpMRI AND CEUS IMAGING TO HISTOLOGY IN RADICAL PROSTATECTOMY SPECIMEN
MP46-07 PRELIMINARY RESULTS OF IN VIVO FOCAL TRANSPERINEAL LASER ABLATION TREATMENT OF THE PROSTATE: CORRELATION OF mpMRI AND CEUS IMAGING TO HISTOLOGY IN RADICAL PROSTATECTOMY SPECIMEN Open
You have accessJournal of UrologyProstate Cancer: Localized: Ablative Therapy (MP46)1 Sep 2021MP46-07 PRELIMINARY RESULTS OF IN VIVO FOCAL TRANSPERINEAL LASER ABLATION TREATMENT OF THE PROSTATE: CORRELATION OF mpMRI AND CEUS IMAGING TO HIS…
View article: Bronchoscopic needle-based confocal laser endomicroscopy (nCLE) as a real-time detection tool for peripheral lung cancer
Bronchoscopic needle-based confocal laser endomicroscopy (nCLE) as a real-time detection tool for peripheral lung cancer Open
Introduction Diagnosing peripheral lung cancer with the bronchoscope is challenging with near miss of the target lesion as major obstacle. Needle-based confocal laser endomicroscopy (nCLE) enables real-time microscopic tumour visualisation…