I. Golutvin
YOU?
Author Swipe
View article: Erratum: Dose rate effects in the radiation damage of the plastic scintillators of the CMS hadron endcap calorimeter
Erratum: Dose rate effects in the radiation damage of the plastic scintillators of the CMS hadron endcap calorimeter Open
Subsequent to the publication of this paper, one of the hybrid photodiodes used as the photode- tector was removed and highly localized damage on its photocathode was discovered. The study of the photodiode cathode was published in Review …
View article: Brightness and uniformity measurements of plastic scintillator tiles at the CERN H2 test beam
Brightness and uniformity measurements of plastic scintillator tiles at the CERN H2 test beam Open
We study the light output, light collection efficiency and signal timing of a variety of organic scintillators that are being considered for the upgrade of the hadronic calorimeter of the CMS detector. The experimental data are collected a…
View article: CMS Endcap Calorimeter for HL-LHC design. Trays Skirt for Backing HE Endcap Calorimeter accessibility. Technical proposal.
CMS Endcap Calorimeter for HL-LHC design. Trays Skirt for Backing HE Endcap Calorimeter accessibility. Technical proposal. Open
The existing Compact Muon Solenoid (CMS) Endcap Hadron Calorimeters (HE) have been in operation for several years and contributed substantially to the success of the CMS Physics Program. The High Luminosity Large Hadron Collider (HL-LHC) p…
View article: A New Segment Building Algorithm for the Cathode Strip Chambers in the CMS Experiment
A New Segment Building Algorithm for the Cathode Strip Chambers in the CMS Experiment Open
\nA new segment building algorithm for the Cathode Strip Chambers in the CMS experiment is presented. A detailed description of the new algorithm is given along with a comparison with the algorithm used in the CMS software. The new segment…
View article: RDMS CMS computing: current status and plans
RDMS CMS computing: current status and plans Open
The Compact Muon Solenoid (CMS) is a high-performance general-purpose detector at the Large Hadron Collider (LHC) at CERN. More than twenty institutes from Russia and Joint Institute for Nuclear Research (JINR) are involved in Russia and D…
View article: "Finger" structure of tiles in CMS Endcap Hadron Calorimeters
"Finger" structure of tiles in CMS Endcap Hadron Calorimeters Open
Two CMS Endcap hadron calorimeters (HE) have been in operation for several years and contributed substantially to the success of the CMS Physics Program. The HE calorimeter suffered more from the radiation than it had been anticipated beca…