W. Simon
YOU?
Author Swipe
View article: Evanescent-Wave Spectroscopy on Bulk-Response Optode Membranes
Evanescent-Wave Spectroscopy on Bulk-Response Optode Membranes Open
The absorbance of a solvent polymerie bulk optode membrane in contact with sapphire as a wave-guide is studied with the attenuated total reflection (ATR) technique. Utilizing thin (≤ 1 μm) and, therefore, fast-responding membranes, high va…
View article: Potentiometric Detector for Capillary Zone Electrophoresis
Potentiometric Detector for Capillary Zone Electrophoresis Open
The use of a potentiometric microelectrode as an end-column detector in capillary zone electrophoresis (CZE) is described. Uncoated fused silica capillaries with an internal diameter (I. D.) of 25 μm are used. The microelectrode is placed …
View article: Potentiometric Detector for Capillary Zone Electrophoresis
Potentiometric Detector for Capillary Zone Electrophoresis Open
The use of a potentiometric microelectrode as an end-column detector in capillary zone electrophoresis (CZE) is described. Uncoated fused silica capillaries with an internal diameter (I. D.) of 25 ?m are used. The microelectrode is placed …
View article: ION-SELECTIVE SENSORS FOR CLINICAL ANALYSIS
ION-SELECTIVE SENSORS FOR CLINICAL ANALYSIS Open
View article: New Solid-State Contact for lon-Selective Liquid Membrane Electrodes
New Solid-State Contact for lon-Selective Liquid Membrane Electrodes Open
A new kind of solid-state contact for ion-selective electrodes based on solvent polymeric membranes is described. These electrodes show similar electrochemical behaviour to conventional ion-selective membranes in contact with an internal f…
View article: Neutral ionophore-based selective electrode for assaying the activity of magnesium in undiluted blood serum
Neutral ionophore-based selective electrode for assaying the activity of magnesium in undiluted blood serum Open
The concentration of free, ionized magnesium in undiluted blood serum can be determined potentiometrically with a new magnesium-selective carrier in polymeric membrane electrodes (by weight 66% plasticizer, approximately 33% polyvinyl chlo…
View article: Very Lipophilic Ca2<sup>⊕</sup>-Selective Ionophore for Chemical Sensors of High Lifetime
Very Lipophilic Ca2<sup>⊕</sup>-Selective Ionophore for Chemical Sensors of High Lifetime Open
Ionophores based on 3-oxapentane-1,5-diamide derivatives with water/1-n-octanol partition coefficients up to 1022 were synthesized. They have sufficient lipophilicity to be used in solvent polymeric membranes for optodes, ISFET’s, and ion-…
View article: Anion-Selective Optical Sensors Based on a Coextraction of Anion-Proton Pairs into a Solvent-Polymeric Membrane
Anion-Selective Optical Sensors Based on a Coextraction of Anion-Proton Pairs into a Solvent-Polymeric Membrane Open
The design of optical sensing devices for anions based on the coextraction of anions and protons into a PVC membrane is described. The extraction is controlled by the lipophilicity of the anions, while the coextracted protons in conjunctio…
View article: Influence of a Classical Chelate Effect due to a Covalent Linkage of Ionophore Subunits on the Performance of Corresponding Ion Selective Electrodes
Influence of a Classical Chelate Effect due to a Covalent Linkage of Ionophore Subunits on the Performance of Corresponding Ion Selective Electrodes Open
View article: An lon-Selective Photodiode (ISPD)
An lon-Selective Photodiode (ISPD) Open
A simple ion-selective chemical sensor with an optical transduction (optode) based on a photodiode with limited spectral response is described.
View article: Carriers for chemical sensors: Design features of optical sensors (optodes) based on selective chromoionophores
Carriers for chemical sensors: Design features of optical sensors (optodes) based on selective chromoionophores Open
View article: Design features of ionophores for ion selective electrodes
Design features of ionophores for ion selective electrodes Open
View article: Carbonate-Selective Chromoionophores
Carbonate-Selective Chromoionophores Open
Three members of a new class of carbonate-selective ion carriers based on trifluoroacetylazobenzene were synthesized and the influence of carbonate on their UV- spectra has been studied.
View article: Intracellular neutral carrier-based Ca2+ microelectrode with subnanomolar detection limit
Intracellular neutral carrier-based Ca2+ microelectrode with subnanomolar detection limit Open
View article: Plasticizers of High Lipophilicities for Clinically Relevant Ion-Selective Electrodes (ISE) and Multisensing Field Effect Transistors (ISFET)
Plasticizers of High Lipophilicities for Clinically Relevant Ion-Selective Electrodes (ISE) and Multisensing Field Effect Transistors (ISFET) Open
Two new types of plasticizers based on tetracarboxylated benzophenone and benzhydrol, respectively, are presented. They exhibit superior performance particularly in ion-selective solvent polymeric membrane electrodes. Their high lipophilic…
View article: Ion-selective membrane electrodes for clinical use.
Ion-selective membrane electrodes for clinical use. Open
We review ion-selective solvent polymeric membrane electrodes for clinical use. The particular requirements that the clinical application set on the membrane are discussed in terms of selectivity, stability, lifetime, and response time. Th…
View article: Lipophilic Neutral Carriers for Lithium Selective Liquid Membrane Electrodes
Lipophilic Neutral Carriers for Lithium Selective Liquid Membrane Electrodes Open
Lipophilic neutral carriers have been designed and characterized in liquid membrane electrodes in view of Li+-activity measurements. One representative shows sufficient selectivities for the measurement of Li+-ions in blood during the ther…
View article: Determination of [K+] in blood serum with a valinomycin-based silicone rubber membrane of universal applicability to body fluids.
Determination of [K+] in blood serum with a valinomycin-based silicone rubber membrane of universal applicability to body fluids. Open
Journal Article Determination of [K+] in blood serum with a valinomycin-based silicone rubber membrane of universal applicability to body fluids. Get access P Anker, P Anker Search for other works by this author on: Oxford Academic Google …
View article: Picoliter Cell Volume Potentiometric Detector for Open-Tubular Column LC
Picoliter Cell Volume Potentiometric Detector for Open-Tubular Column LC Open
ISSN:0021-9665
View article: Applicability of a Carrier Based Liquid Membrane <i>p</i>H Electrode to Measurements in Acidic Solutions
Applicability of a Carrier Based Liquid Membrane <i>p</i>H Electrode to Measurements in Acidic Solutions Open
A solvent polymeric membrane electrode based on a synthetic H+-carrier is described. The incorporation of the potassium salt of tetrakis(p-chlorophenyl)borate into the membrane phase leads to electrode systems which are suitable for pH mea…
View article: Selective Transport, Coupled to a Counterflow of Protons, of Ions Across Neutral Carrier Membranes
Selective Transport, Coupled to a Counterflow of Protons, of Ions Across Neutral Carrier Membranes Open
Neutral carrier membranes can transport ions with high selectivity. A specific transport of calcium ions under zero-current conditions has been realized by adding proton carriers to the membrane phase and exposing it to a pH gradient. The …
View article: Liquid Membrane <i>p</i>H Electrode Based on a Synthetic Proton Carrier
Liquid Membrane <i>p</i>H Electrode Based on a Synthetic Proton Carrier Open
A new synthetic H+-selective ion-carrier suitable as a component for liquid membrane electrodes is described. Electrodes based on PVC membranes make possible the measurement of physiological H+ ion activities in the presence of typical ext…
View article: On-line continuous potentiometric measurement of potassium concentration in whole blood during open-heart surgery.
On-line continuous potentiometric measurement of potassium concentration in whole blood during open-heart surgery. Open
We describe a flow-through system with an ion-selective electrode for measurement of blood potassium ion concentration, continuously and on-line off the extracorporeal blood circulation in an operating theater during human open-heart surge…
View article: Neutral Carrier Ca<sup>2+</sup>-Microelectrode
Neutral Carrier Ca<sup>2+</sup>-Microelectrode Open
The use of a synthetic electrically neutral ion carrier in Ca2+- selective microelectrodes is described. High ion-selectivities especially in respect to Na+ and Mg2+ as well as a long lifetime of the electrodes open new possibilities for a…
View article: Enantiomerenselektives Verhalten in Membranen eines chiralen, elektrisch neutralen Ionophors
Enantiomerenselektives Verhalten in Membranen eines chiralen, elektrisch neutralen Ionophors Open
A chiral, electrically neutral carrier is shown to possess enantiomer-selective properties in complexation with α-phenylethyl ammonium ions. As measured in e.m.f. and transport experiments, the selectivity for one enantiomer over the other…
View article: Recent developments in the field of ion selective electrodes
Recent developments in the field of ion selective electrodes Open
View article: Calcium Carrier Properties of Neutral Synthetic Ligands in Bulk Membranes
Calcium Carrier Properties of Neutral Synthetic Ligands in Bulk Membranes Open
A group of electrically neutral, acyclic and lipophilic ligands have been found to induce a selective Ca2+ transport through PVC bulk membranes when a potential gradient is applied. An infrared spectroscopic study demonstrated the mobility…
View article: Transient Nutations in <sup>1</sup>H{<sup>14</sup>N} Nuclear Magnetic Double Resonance
Transient Nutations in <sup>1</sup>H{<sup>14</sup>N} Nuclear Magnetic Double Resonance Open
Transient nutations in 1H{14N} nuclear magnetic double resonance are described. The high symmetry of the ammonium, tetramethylammonium and tetraethylammonium cations allowed the detection of two different types of transient nutations. One …
View article: Ion selective sensors
Ion selective sensors Open
View article: Antibiotika-Membranelektrode zur selektiven Erfassung von Ammoniumionenaktivitäten
Antibiotika-Membranelektrode zur selektiven Erfassung von Ammoniumionenaktivitäten Open
A new liquid-membrane electrode using macrotetrolide antibiotics as ion selective component is described. The electrode shows selectivities of NH4+ over K+ and NH4+ over Na+ of about 10 and over 500 respectively and a linear response to NH…