Xiaobing Zheng
YOU?
Author Swipe
View article: Continuous linearity evaluation of photodetectors using a cascaded integrating-sphere system
Continuous linearity evaluation of photodetectors using a cascaded integrating-sphere system Open
Traditional nonlinearity measurements are limited by the detector’s dynamic range, especially at extremely low light levels. We present a cascaded integrating-sphere system combined with an aperture tube, enabling continuous optical attenu…
View article: Measurement method of the solar diffuser bidirectional reflectance distribution function in the short-wave infrared band
Measurement method of the solar diffuser bidirectional reflectance distribution function in the short-wave infrared band Open
In the solar reflective band, the on-board calibration method based on a solar diffuser (SD) is the mainstream calibration method. However, the calibration accuracy is limited by the measurement accuracy of the SD bidirectional reflectance…
View article: Study on the correction factors in detection efficiency measurements based on spontaneous parametric down-conversion
Study on the correction factors in detection efficiency measurements based on spontaneous parametric down-conversion Open
This study discusses the correction factors in detection efficiency measurements based on spontaneous parametric down-conversion (SPDC) and coincidence counting. To address the coincidence loss induced by relative delays between two detect…
View article: High-Precision 3D Mapping In Tunnels Based on Vibration Magnitude-Adaptive Kalman Filtering
High-Precision 3D Mapping In Tunnels Based on Vibration Magnitude-Adaptive Kalman Filtering Open
View article: High <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mi>Q</mml:mi></mml:math> and high gradient performance of the first medium-temperature baking 1.3 GHz cryomodule
High and high gradient performance of the first medium-temperature baking 1.3 GHz cryomodule Open
The world’s first 1.3 GHz cryomodule containing eight 9-cell superconducting radio-frequency (rf) cavities treated by medium-temperature furnace baking (mid-T bake) was developed at the Institute of High Energy Physics, Chinese Academy of …
View article: Recent advance progress of HL-3 experiments
Recent advance progress of HL-3 experiments Open
Since the first plasma realized in 2020, a series of key systems on HL-3 (known as HL-2M before) tokamak have been equipped/upgraded, including in-vessel components (the first wall, lower divertor, and toroidal cryogenic/water-cooling/baki…
View article: Wide Dynamic Range, High Uniformity Spectral Irradiance Source for Calibration of Scientific-Grade, Large-Size Space Detectors
Wide Dynamic Range, High Uniformity Spectral Irradiance Source for Calibration of Scientific-Grade, Large-Size Space Detectors Open
In order to meet the high uniformity calibration requirements for scientific-grade, large-size space detectors used in the CHES Extrasolar Planet Exploration Mission, this paper presents the design of a wide dynamic range, high uniformity …
View article: Detection efficiency measurement of an up-conversion single-photon detector at 3.39μm based on SPDC
Detection efficiency measurement of an up-conversion single-photon detector at 3.39μm based on SPDC Open
Up-conversion single-photon detector (UCSPD) is promising in weak light radiometry at mid-infrared spectrum. This paper proposed a method to measure the detection efficiency of UCSPD at 3.39μm based on the visible-infrared correlated photo…
View article: A Wide-Angle Hyperspectral Top-of-Atmosphere Reflectance Model for the Libyan Desert
A Wide-Angle Hyperspectral Top-of-Atmosphere Reflectance Model for the Libyan Desert Open
Reference targets with stability, uniformity, and known reflectance on the Earth’s surface, such as deserts, can be used for the absolute radiometric calibration of satellite sensors. A wide-angle hyperspectral reflectance model at the top…
View article: Research on Algorithm for Extracting the Position of Tunnel Steel Arch Based on Lidar Point Cloud
Research on Algorithm for Extracting the Position of Tunnel Steel Arch Based on Lidar Point Cloud Open
View article: Optical Design and Spectral Calibration of the Vis-Nir Irradiance Monitor
Optical Design and Spectral Calibration of the Vis-Nir Irradiance Monitor Open
View article: High Q and high gradient performance of the first medium-temperature baking 1.3 GHz cryomodule
High Q and high gradient performance of the first medium-temperature baking 1.3 GHz cryomodule Open
World's first 1.3 GHz cryomodule containing eight 9-cell superconducting radio-frequency (RF) cavities treated by medium-temperature furnace baking (mid-T bake) was developed, assembled and tested at IHEP for the Dalian Advanced Light Sour…
View article: Nonlinearity Measurement of Si Transferring Photodetector in the Low Radiation Flux Range
Nonlinearity Measurement of Si Transferring Photodetector in the Low Radiation Flux Range Open
In order to establish a transferring chain from a photon flux of a single-photon source in quantum radiometry, the nonlinearity of the photodetector needs to be accurately measured. Using the flux superposition method, a nonlinearity measu…
View article: High Accuracy Solar Diffuser BRDF Measurement for On-Board Calibration in the Solar Reflective Band
High Accuracy Solar Diffuser BRDF Measurement for On-Board Calibration in the Solar Reflective Band Open
In the solar reflective band, an on-board calibration method based on a solar diffuser (SD) can realize full aperture, full field of view, and end-to-end absolute radiometric calibration of optical remote sensors. The SD’s bidirectional re…
View article: Study of 256 fiber array biaxial LiDAR optical assembly measurements
Study of 256 fiber array biaxial LiDAR optical assembly measurements Open
This paper presents a method for measuring the optical assembly results based on multi-beam biaxial LiDAR. This method analyzes the optical assembly parameters of a LiDAR system affecting the LiDAR operation, and an experimental measuremen…
View article: Nanodroplet‐Coated Microbubbles Used in Sonothrombolysis with Two‐Step Cavitation Strategy (Adv. Healthcare Mater. 6/2023)
Nanodroplet‐Coated Microbubbles Used in Sonothrombolysis with Two‐Step Cavitation Strategy (Adv. Healthcare Mater. 6/2023) Open
Microbubbles In article 2202281 by Jiang Li, Haosheng Chen, and co-workers, nanodroplet-coated microbubbles (NCMBs) are designed to realize a two-step cavitation strategy to accelerate thrombolysis. The first cavitation drives nanodroplets…
View article: Cross-calibration method based on an automated observation site
Cross-calibration method based on an automated observation site Open
Cross-calibration methods are widely used in high-precision remote sensor calibrations and ensure observational consistency between sensors. Because two sensors must be observed under the same or similar conditions, the cross-calibration f…
View article: Parasitic modes suppression in CW cold tests of 1.3 GHz 9-cell high Q cavities at IHEP
Parasitic modes suppression in CW cold tests of 1.3 GHz 9-cell high Q cavities at IHEP Open
The CW RF test of 1.3 GHz 9-cell cavity in liquid helium bath at 2 K is a very important key point in the cavity procurement. Some problems can be found through the test, according which to optimized and improve the process of cavity. Rece…
View article: Analysis of the Spatial Properties of Correlated Photon in Collinear Phase-Matching
Analysis of the Spatial Properties of Correlated Photon in Collinear Phase-Matching Open
In this paper, the spatial properties of correlated photon in collinear phase-matching in the process of spontaneous parametric down conversion (SPDC) are researched. Based on the study of the phase-matching angle, non-collinear angle, and…
View article: Vicarious Radiometric Calibration of Ocean Color Bands for FY-3D/MERSI-II at Lake Qinghai, China
Vicarious Radiometric Calibration of Ocean Color Bands for FY-3D/MERSI-II at Lake Qinghai, China Open
To calibrate the low signal response of the ocean color (OC) bands and test the stability of the Fengyun-3D (FY-3D)/Medium Resolution Spectral Imager II (MERSI-II), an absolute radiometric calibration field test of FY-3D/MERSI-II at the La…
View article: Medium-temperature furnace bake of Superconducting Radio-Frequency cavities at IHEP
Medium-temperature furnace bake of Superconducting Radio-Frequency cavities at IHEP Open
Recently, heat treatment between 250 C and 500 C has been attempted to improve quality factor of superconducting radio-frequency cavities at FNAL and KEK. Experiments of such medium temperature (mid-T) bake with furnaces have also been car…
View article: POLARIMETRIC CALIBRATION OF THE SPACEBORNE DIRECTIONAL POLARIMETRIC CAMERA INSTALLED ON THE GF-5 SATELLITE
POLARIMETRIC CALIBRATION OF THE SPACEBORNE DIRECTIONAL POLARIMETRIC CAMERA INSTALLED ON THE GF-5 SATELLITE Open
The Spaceborne Directional Polarimetric Camera (SDPC) is dedicated to obtain an accurate information of clouds and microphysical properties of aerosol particles via multi-angle, multi-spectral and multi-polarization observations. It images…
View article: Development of the Chinese Space-Based Radiometric Benchmark Mission LIBRA
Development of the Chinese Space-Based Radiometric Benchmark Mission LIBRA Open
Climate observations and their applications require measurements with high stability and low uncertainty in order to detect and assess climate variability and trends. The difficulty with space-based observations is that it is generally not…
View article: SI Traceable Solar Spectral Irradiance Measurement Based on a Quantum Benchmark: A Prototype Design
SI Traceable Solar Spectral Irradiance Measurement Based on a Quantum Benchmark: A Prototype Design Open
We propose a space benchmark sensor with onboard SI (Système International) traceability by means of quantum optical radiometry. Correlated photon pairs generated by spontaneous parametric down-conversion (SPDC) in nonlinear crystals are u…
View article: Introduction of the radiometric benchmark satellite being developed in China for remote sensing
Introduction of the radiometric benchmark satellite being developed in China for remote sensing Open
ä¸ºç¡®ä¿æ°æ®çå®éååºç¨ï¼å½é èªå¤©é¥æå¤§å½å§ç»å´ç»å®æ ææ¯å¼å±ç ç©¶ï¼å®æ ç²¾åº¦ä¸ææé«ãå¨ç»åæ°åå¹´åå±ä¹åï¼åä¼ ç»çé¥æè½½è·å®æ ç³»ç»è®¾è®¡ä»¥åå°é¢è¾å°æ ¡æ£ææ¯ç论æ…
View article: Investigation on hydrodynamic lubrication of bearings in a left ventricular assisted device
Investigation on hydrodynamic lubrication of bearings in a left ventricular assisted device Open
Formations of clots were found inside the hydrodynamic bearings of the left ventricular assisted devices (LVADs) and caused tremendous risks to the long-term use of these devices. For the hydrodynamic bearings used in the LVAD, not only th…
View article: Design and Simulation of Trajectory Tracking Guidance Law Based on LQR for Target Missile
Design and Simulation of Trajectory Tracking Guidance Law Based on LQR for Target Missile Open
Aiming at the trajectory tracking problem of the target projectile, a ballistic tracking guidance law of the target projectile is designed based on the linear quadratic regulator (LQR) theory. Using time as an independent variable, the mot…
View article: Effect of divergence angle of polarization calibration source on DPC polarization calibration: Analysis and validation
Effect of divergence angle of polarization calibration source on DPC polarization calibration: Analysis and validation Open
å¤è§åº¦åæ¯æå仪(DPC)æ¯ä¸ç§å¤è§åº¦ãå¤å è°±å ·å¤åæ¯æµéåè½ç大è§åºåæ¯é¥æå¨ã忝宿 å æºç忣è§ä¸DPCåå 对åºçè§åºè§å¹é ä¸è´ï¼æ¯æåDPCå®éªå®¤åæ¯å®æ 精度çå ³é®å …
View article: Absolute calibration of the InSb analog detector based on parametric-down-conversion
Absolute calibration of the InSb analog detector based on parametric-down-conversion Open
Currently the two major generally radiometric calibration methods including standard radiometric source and detectors are realized by standard transfer, but it is difficult to overcome the cumulative error during its calibration processes.…
View article: Novel calibration optical path of cryogenic radiometer
Novel calibration optical path of cryogenic radiometer Open
We introduce a novel calibration optical path of the cryogenic radiometer, which can avoid the repeated dismounting measurement and eliminate the negative influence of Brewster window effect on calibration result. The novel calibration opt…