Yuanbin Zhao
YOU?
Author Swipe
View article: Abnormal brain iron deposition in patients with new daily persistent headache: a prospective quantitative susceptibility mapping study
Abnormal brain iron deposition in patients with new daily persistent headache: a prospective quantitative susceptibility mapping study Open
Our findings indicated that the metabolic disorder of iron deposition in specific areas of the brain may be related to the underlying pathogenesis of patients with NDPH. These findings should be regarded as preliminary exploratory results,…
View article: Excessive iron accumulation in the striatum associated with addictive behaviors of medication-overuse headache: a prospective study
Excessive iron accumulation in the striatum associated with addictive behaviors of medication-overuse headache: a prospective study Open
CM patients with MOH had excessive iron deposition in basal ganglia regions, including the caudate, putamen, and GP, which may be related to the medication overuse behavior. Iron deposition in the caudate and putamen may be a potential bio…
View article: A radiomic model based on 7T intracranial vessel wall imaging for identification of culprit middle cerebral artery plaque associated with subcortical infarctions
A radiomic model based on 7T intracranial vessel wall imaging for identification of culprit middle cerebral artery plaque associated with subcortical infarctions Open
The radiomics approach based on 7.0T HR-VWI can accurately identify culprit plaques associated with subcortical infarctions, potentially better than conventional HR-VWI features.
View article: Gamma-aminobutyric acid and glutamate/glutamine levels in the dentate nucleus and periaqueductal gray in new daily persistent headache: a magnetic resonance spectroscopy study
Gamma-aminobutyric acid and glutamate/glutamine levels in the dentate nucleus and periaqueductal gray in new daily persistent headache: a magnetic resonance spectroscopy study Open
View article: Study on the Influence of Circulating Water Bypass on the Thermal and Anti-Freezing Characteristics of High-Level Wet Cooling Tower
Study on the Influence of Circulating Water Bypass on the Thermal and Anti-Freezing Characteristics of High-Level Wet Cooling Tower Open
When heating units are operated in winter, the extreme conditions, such as deep peak regulation and large extraction, can easily lead to a low unit load and severe icing in the wet cooling tower, which threatens the safe operation of the u…
View article: Air Equalizing Mechanism in Cooling Performance Improvement of Vertical Delta-Type Radiators
Air Equalizing Mechanism in Cooling Performance Improvement of Vertical Delta-Type Radiators Open
Based on the design and measured data of one actual tower, a three-dimensional numerical model for a natural draft dry cooling tower (NDDCT) was created and validated under constant heat load. This enabled the performance improvement mecha…
View article: Anti-Freezing Study of High-Level Water-Collecting Natural Draft Wet-Cooling Tower Based on Its Water Temperature Distribution Characteristics
Anti-Freezing Study of High-Level Water-Collecting Natural Draft Wet-Cooling Tower Based on Its Water Temperature Distribution Characteristics Open
Thermal power units play a crucial role in the deep peak regulation of power generation. During deep peak regulation, the load of the unit changes significantly, causing fluctuations in the inlet water temperature of the cooling tower and …
View article: Numerical Study on the Influence Mechanism of Crosswind on Frozen Phenomena in a Direct Air-Cooled System
Numerical Study on the Influence Mechanism of Crosswind on Frozen Phenomena in a Direct Air-Cooled System Open
The frozen phenomenon is unfavorable for the direct air-cooled condensers (DACCs) in a very cold area. The effect of crosswind on frozen phenomena in DACCs at the representative 2 × 350 MW thermal power units was investigated numerically. …
View article: Evaluation of the Hot Air Recirculation Effect and Relevant Empirical Formulae Applicability for Mechanical Draft Wet Cooling Towers
Evaluation of the Hot Air Recirculation Effect and Relevant Empirical Formulae Applicability for Mechanical Draft Wet Cooling Towers Open
Due to the hot air recirculation, the inlet air enthalpy h1 of mechanical draft wet cooling towers (MCTs) was usually greater than the ambient air enthalpy ha. To realize the cooling performance and accurate design of MCTs, this paper clar…
View article: Numerical Investigation on the Influence of Mechanical Draft Wet-Cooling Towers on the Cooling Performance of Air-Cooled Condenser with Complex Building Environment
Numerical Investigation on the Influence of Mechanical Draft Wet-Cooling Towers on the Cooling Performance of Air-Cooled Condenser with Complex Building Environment Open
In air-cooled power units, an air-cooled condenser (ACC) is usually accompanied by mechanical draft wet-cooling towers (MCTs) so as to meet the severe cooling requirements of air-cooling auxiliary apparatuses, such as water ring vacuum pum…
View article: Influence of crosswind on heller natural draft dry cooling tower and improvement measures
Influence of crosswind on heller natural draft dry cooling tower and improvement measures Open
Papers presented at the 13th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Portoroz, Slovenia on 17-19 July 2017 .